Cargando…

Commissioning and Operation of the MedAustron Injector: Results and Future Outlook

The MedAustron facility is a synchrotron-driven hadron therapy and research center presently under construction in Wiener Neustadt, Austria. In its final outline, the facility will provide H⁺ beams with kinetic energies ≤250MeV and C6+ beams of ≤400MeV/u for clinical applications, and for non-clinic...

Descripción completa

Detalles Bibliográficos
Autores principales: Penescu, Liviu, Kronberger, Matthias, Kulenkampff, Tobias, Osmić, Fadmar, Urschütz, Peter, Pirkl, Werner
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/2003190
_version_ 1780946193003577344
author Penescu, Liviu
Kronberger, Matthias
Kulenkampff, Tobias
Osmić, Fadmar
Urschütz, Peter
Pirkl, Werner
author_facet Penescu, Liviu
Kronberger, Matthias
Kulenkampff, Tobias
Osmić, Fadmar
Urschütz, Peter
Pirkl, Werner
author_sort Penescu, Liviu
collection CERN
description The MedAustron facility is a synchrotron-driven hadron therapy and research center presently under construction in Wiener Neustadt, Austria. In its final outline, the facility will provide H⁺ beams with kinetic energies ≤250MeV and C6+ beams of ≤400MeV/u for clinical applications, and for non-clinical applications H⁺ of up to 800MeV. First patient treatment is foreseen for the end of 2015. The (H3)+ and C4+ beams are generated at 8keV/u in continuous mode by three ECR ion sources and transported to the RFQ for acceleration to 400keV/u. An inter-tank section matches the beam to the entrance of an IH-mode DTL that accelerates the particles to 7MeV/u before they are stripped to, respectively, H⁺ and C6+, debunched and transported to the injection plane of the synchrotron. At a later stage of the project, beams of other species can be generated with similar optics. This contribution presents the results of the injector commissioning and operation. A comparison with the baseline optics and with the design error studies is given. In addition, an overview on the operational experience is given, with emphasis on the system reliability, stability and reproducibility.
id oai-inspirehep.net-1314730
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling oai-inspirehep.net-13147302022-08-17T13:30:41Zhttp://cds.cern.ch/record/2003190engPenescu, LiviuKronberger, MatthiasKulenkampff, TobiasOsmić, FadmarUrschütz, PeterPirkl, WernerCommissioning and Operation of the MedAustron Injector: Results and Future OutlookAccelerators and Storage RingsThe MedAustron facility is a synchrotron-driven hadron therapy and research center presently under construction in Wiener Neustadt, Austria. In its final outline, the facility will provide H⁺ beams with kinetic energies ≤250MeV and C6+ beams of ≤400MeV/u for clinical applications, and for non-clinical applications H⁺ of up to 800MeV. First patient treatment is foreseen for the end of 2015. The (H3)+ and C4+ beams are generated at 8keV/u in continuous mode by three ECR ion sources and transported to the RFQ for acceleration to 400keV/u. An inter-tank section matches the beam to the entrance of an IH-mode DTL that accelerates the particles to 7MeV/u before they are stripped to, respectively, H⁺ and C6+, debunched and transported to the injection plane of the synchrotron. At a later stage of the project, beams of other species can be generated with similar optics. This contribution presents the results of the injector commissioning and operation. A comparison with the baseline optics and with the design error studies is given. In addition, an overview on the operational experience is given, with emphasis on the system reliability, stability and reproducibility.oai:inspirehep.net:13147302014
spellingShingle Accelerators and Storage Rings
Penescu, Liviu
Kronberger, Matthias
Kulenkampff, Tobias
Osmić, Fadmar
Urschütz, Peter
Pirkl, Werner
Commissioning and Operation of the MedAustron Injector: Results and Future Outlook
title Commissioning and Operation of the MedAustron Injector: Results and Future Outlook
title_full Commissioning and Operation of the MedAustron Injector: Results and Future Outlook
title_fullStr Commissioning and Operation of the MedAustron Injector: Results and Future Outlook
title_full_unstemmed Commissioning and Operation of the MedAustron Injector: Results and Future Outlook
title_short Commissioning and Operation of the MedAustron Injector: Results and Future Outlook
title_sort commissioning and operation of the medaustron injector: results and future outlook
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/2003190
work_keys_str_mv AT penesculiviu commissioningandoperationofthemedaustroninjectorresultsandfutureoutlook
AT kronbergermatthias commissioningandoperationofthemedaustroninjectorresultsandfutureoutlook
AT kulenkampfftobias commissioningandoperationofthemedaustroninjectorresultsandfutureoutlook
AT osmicfadmar commissioningandoperationofthemedaustroninjectorresultsandfutureoutlook
AT urschutzpeter commissioningandoperationofthemedaustroninjectorresultsandfutureoutlook
AT pirklwerner commissioningandoperationofthemedaustroninjectorresultsandfutureoutlook