An SRAM Based Monitor for Mixed-Field Radiation Environments

CERN hosts a large number of electronic devices and equipment, functioning over its different particle accelerators. In certain areas, they operate in harsh radiation environments. In order to assure their proper functionality, the equipment or some of their sensitive components undergo several test...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsiligiannis, G, Dilillo, L, Bosio, A, Girard, P, Pravossoudovitch, S, Todri, A, Virazel, A, Mekki, J, Brugger, M, Wrobel, F, Saigné, F
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TNS.2014.2299733
http://cds.cern.ch/record/2124822
_version_ 1780949655191814144
author Tsiligiannis, G
Dilillo, L
Bosio, A
Girard, P
Pravossoudovitch, S
Todri, A
Virazel, A
Mekki, J
Brugger, M
Wrobel, F
Saigné, F
author_facet Tsiligiannis, G
Dilillo, L
Bosio, A
Girard, P
Pravossoudovitch, S
Todri, A
Virazel, A
Mekki, J
Brugger, M
Wrobel, F
Saigné, F
author_sort Tsiligiannis, G
collection CERN
description CERN hosts a large number of electronic devices and equipment, functioning over its different particle accelerators. In certain areas, they operate in harsh radiation environments. In order to assure their proper functionality, the equipment or some of their sensitive components undergo several tests in experimental test areas representative of the LHC radiation fields, while specialized monitors constantly record the respective radiation levels. The purpose of this study is to evaluate the use of monitors using recent technology nodes (90 nm) in order to have a better estimation of the expected error rate of the devices. The H4IRRAD experimental test area has been specifically designed to reproduce the radiation field that is present within the LHC tunnel and shielded areas. It has been used to test our custom SRAM based monitors. The monitors have been exposed to a maximum dose and high energy hadron fluence of about 76 Gy and 1.3 × 10^11 cm^-2 respectively. The results show that the total ionizing dose (TID) effect does not impact the bit cross section of our devices. Moreover the Single Event occurrence is coherent to the beam intensity fluctuations, proving that these devices are appropriate for SEU monitoring under mixed particle fields.
id oai-inspirehep.net-1317575
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling oai-inspirehep.net-13175752019-09-30T06:29:59Zdoi:10.1109/TNS.2014.2299733http://cds.cern.ch/record/2124822engTsiligiannis, GDilillo, LBosio, AGirard, PPravossoudovitch, STodri, AVirazel, AMekki, JBrugger, MWrobel, FSaigné, FAn SRAM Based Monitor for Mixed-Field Radiation EnvironmentsDetectors and Experimental TechniquesCERN hosts a large number of electronic devices and equipment, functioning over its different particle accelerators. In certain areas, they operate in harsh radiation environments. In order to assure their proper functionality, the equipment or some of their sensitive components undergo several tests in experimental test areas representative of the LHC radiation fields, while specialized monitors constantly record the respective radiation levels. The purpose of this study is to evaluate the use of monitors using recent technology nodes (90 nm) in order to have a better estimation of the expected error rate of the devices. The H4IRRAD experimental test area has been specifically designed to reproduce the radiation field that is present within the LHC tunnel and shielded areas. It has been used to test our custom SRAM based monitors. The monitors have been exposed to a maximum dose and high energy hadron fluence of about 76 Gy and 1.3 × 10^11 cm^-2 respectively. The results show that the total ionizing dose (TID) effect does not impact the bit cross section of our devices. Moreover the Single Event occurrence is coherent to the beam intensity fluctuations, proving that these devices are appropriate for SEU monitoring under mixed particle fields.oai:inspirehep.net:13175752014
spellingShingle Detectors and Experimental Techniques
Tsiligiannis, G
Dilillo, L
Bosio, A
Girard, P
Pravossoudovitch, S
Todri, A
Virazel, A
Mekki, J
Brugger, M
Wrobel, F
Saigné, F
An SRAM Based Monitor for Mixed-Field Radiation Environments
title An SRAM Based Monitor for Mixed-Field Radiation Environments
title_full An SRAM Based Monitor for Mixed-Field Radiation Environments
title_fullStr An SRAM Based Monitor for Mixed-Field Radiation Environments
title_full_unstemmed An SRAM Based Monitor for Mixed-Field Radiation Environments
title_short An SRAM Based Monitor for Mixed-Field Radiation Environments
title_sort sram based monitor for mixed-field radiation environments
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/TNS.2014.2299733
http://cds.cern.ch/record/2124822
work_keys_str_mv AT tsiligiannisg ansrambasedmonitorformixedfieldradiationenvironments
AT dilillol ansrambasedmonitorformixedfieldradiationenvironments
AT bosioa ansrambasedmonitorformixedfieldradiationenvironments
AT girardp ansrambasedmonitorformixedfieldradiationenvironments
AT pravossoudovitchs ansrambasedmonitorformixedfieldradiationenvironments
AT todria ansrambasedmonitorformixedfieldradiationenvironments
AT virazela ansrambasedmonitorformixedfieldradiationenvironments
AT mekkij ansrambasedmonitorformixedfieldradiationenvironments
AT bruggerm ansrambasedmonitorformixedfieldradiationenvironments
AT wrobelf ansrambasedmonitorformixedfieldradiationenvironments
AT saignef ansrambasedmonitorformixedfieldradiationenvironments
AT tsiligiannisg srambasedmonitorformixedfieldradiationenvironments
AT dilillol srambasedmonitorformixedfieldradiationenvironments
AT bosioa srambasedmonitorformixedfieldradiationenvironments
AT girardp srambasedmonitorformixedfieldradiationenvironments
AT pravossoudovitchs srambasedmonitorformixedfieldradiationenvironments
AT todria srambasedmonitorformixedfieldradiationenvironments
AT virazela srambasedmonitorformixedfieldradiationenvironments
AT mekkij srambasedmonitorformixedfieldradiationenvironments
AT bruggerm srambasedmonitorformixedfieldradiationenvironments
AT wrobelf srambasedmonitorformixedfieldradiationenvironments
AT saignef srambasedmonitorformixedfieldradiationenvironments