Cargando…

Comparison of the performance of different instruments in the stray neutron field around the CERN Proton Synchrotron

This paper discusses an intercomparison campaign carried out in several locations around the CERN Proton Synchrotron. The locations were selected in order to perform the measurements in different stray field conditions. Various neutron detectors were employed: ionisation chambers, conventional and e...

Descripción completa

Detalles Bibliográficos
Autores principales: Aza, Eleni, Caresana, Marco, Cassell, Christopher, Colombo, Valeria, Damjanovic, Sanja, Gilardoni, Simone, Manessi, Giacomo Paolo, Pangallo, Michel, Perrin, Daniel, Silari, Marco
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:https://dx.doi.org/10.1093/rpd/nct215
http://cds.cern.ch/record/2025799
_version_ 1780947219170459648
author Aza, Eleni
Caresana, Marco
Cassell, Christopher
Colombo, Valeria
Damjanovic, Sanja
Gilardoni, Simone
Manessi, Giacomo Paolo
Pangallo, Michel
Perrin, Daniel
Silari, Marco
author_facet Aza, Eleni
Caresana, Marco
Cassell, Christopher
Colombo, Valeria
Damjanovic, Sanja
Gilardoni, Simone
Manessi, Giacomo Paolo
Pangallo, Michel
Perrin, Daniel
Silari, Marco
author_sort Aza, Eleni
collection CERN
description This paper discusses an intercomparison campaign carried out in several locations around the CERN Proton Synchrotron. The locations were selected in order to perform the measurements in different stray field conditions. Various neutron detectors were employed: ionisation chambers, conventional and extended range rem counters, both commercial and prototype ones, including a novel instrument called LUPIN, specifically conceived to work in pulsed fields. The attention was focused on the potential differences in the instrument readings due to dead-time losses that are expected to affect most commercial units. The results show that the ionisation chambers and LUPIN agree well with the expected H*(10) values, as derived from FLUKA simulations, showing no relevant underestimations even in strongly pulsed fields. On the contrary, the dead-time losses of the other rem counters induced an underestimation in pulsed fields that was more important for instruments characterised by a higher dead time.
id oai-inspirehep.net-1320665
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling oai-inspirehep.net-13206652019-09-30T06:29:59Zdoi:10.1093/rpd/nct215http://cds.cern.ch/record/2025799engAza, EleniCaresana, MarcoCassell, ChristopherColombo, ValeriaDamjanovic, SanjaGilardoni, SimoneManessi, Giacomo PaoloPangallo, MichelPerrin, DanielSilari, MarcoComparison of the performance of different instruments in the stray neutron field around the CERN Proton SynchrotronAccelerators and Storage RingsThis paper discusses an intercomparison campaign carried out in several locations around the CERN Proton Synchrotron. The locations were selected in order to perform the measurements in different stray field conditions. Various neutron detectors were employed: ionisation chambers, conventional and extended range rem counters, both commercial and prototype ones, including a novel instrument called LUPIN, specifically conceived to work in pulsed fields. The attention was focused on the potential differences in the instrument readings due to dead-time losses that are expected to affect most commercial units. The results show that the ionisation chambers and LUPIN agree well with the expected H*(10) values, as derived from FLUKA simulations, showing no relevant underestimations even in strongly pulsed fields. On the contrary, the dead-time losses of the other rem counters induced an underestimation in pulsed fields that was more important for instruments characterised by a higher dead time.oai:inspirehep.net:13206652014
spellingShingle Accelerators and Storage Rings
Aza, Eleni
Caresana, Marco
Cassell, Christopher
Colombo, Valeria
Damjanovic, Sanja
Gilardoni, Simone
Manessi, Giacomo Paolo
Pangallo, Michel
Perrin, Daniel
Silari, Marco
Comparison of the performance of different instruments in the stray neutron field around the CERN Proton Synchrotron
title Comparison of the performance of different instruments in the stray neutron field around the CERN Proton Synchrotron
title_full Comparison of the performance of different instruments in the stray neutron field around the CERN Proton Synchrotron
title_fullStr Comparison of the performance of different instruments in the stray neutron field around the CERN Proton Synchrotron
title_full_unstemmed Comparison of the performance of different instruments in the stray neutron field around the CERN Proton Synchrotron
title_short Comparison of the performance of different instruments in the stray neutron field around the CERN Proton Synchrotron
title_sort comparison of the performance of different instruments in the stray neutron field around the cern proton synchrotron
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1093/rpd/nct215
http://cds.cern.ch/record/2025799
work_keys_str_mv AT azaeleni comparisonoftheperformanceofdifferentinstrumentsinthestrayneutronfieldaroundthecernprotonsynchrotron
AT caresanamarco comparisonoftheperformanceofdifferentinstrumentsinthestrayneutronfieldaroundthecernprotonsynchrotron
AT cassellchristopher comparisonoftheperformanceofdifferentinstrumentsinthestrayneutronfieldaroundthecernprotonsynchrotron
AT colombovaleria comparisonoftheperformanceofdifferentinstrumentsinthestrayneutronfieldaroundthecernprotonsynchrotron
AT damjanovicsanja comparisonoftheperformanceofdifferentinstrumentsinthestrayneutronfieldaroundthecernprotonsynchrotron
AT gilardonisimone comparisonoftheperformanceofdifferentinstrumentsinthestrayneutronfieldaroundthecernprotonsynchrotron
AT manessigiacomopaolo comparisonoftheperformanceofdifferentinstrumentsinthestrayneutronfieldaroundthecernprotonsynchrotron
AT pangallomichel comparisonoftheperformanceofdifferentinstrumentsinthestrayneutronfieldaroundthecernprotonsynchrotron
AT perrindaniel comparisonoftheperformanceofdifferentinstrumentsinthestrayneutronfieldaroundthecernprotonsynchrotron
AT silarimarco comparisonoftheperformanceofdifferentinstrumentsinthestrayneutronfieldaroundthecernprotonsynchrotron