Cargando…

The triple GEM detector as stray neutron monitor

A triple GEM detector for low energy neutrons and high rejection of gamma background was tested at the CERF facility at CERN as stray neutron monitor. The detector was exposed to a wide neutron spectrum generated by a 120 GeV/c positively charged hadron beam hitting a copper target. The beam particl...

Descripción completa

Detalles Bibliográficos
Autores principales: Aza, Eleni, Magistris, M, Murtas, F, Puddu, S, Silari, M
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/9/11/T11005
http://cds.cern.ch/record/2003206
_version_ 1780946196227948544
author Aza, Eleni
Magistris, M
Murtas, F
Puddu, S
Silari, M
author_facet Aza, Eleni
Magistris, M
Murtas, F
Puddu, S
Silari, M
author_sort Aza, Eleni
collection CERN
description A triple GEM detector for low energy neutrons and high rejection of gamma background was tested at the CERF facility at CERN as stray neutron monitor. The detector was exposed to a wide neutron spectrum generated by a 120 GeV/c positively charged hadron beam hitting a copper target. The beam particle rate on target ranged over three orders of magnitude. The neutron count rate measured with the GEM could be linearly correlated with the beam intensity and also compared well with Monte Carlo simulations. The detector performance suggests that it can be used as an independent low energy neutron monitor at high-energy particle accelerator facilities.
id oai-inspirehep.net-1328589
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling oai-inspirehep.net-13285892022-08-10T20:11:15Zdoi:10.1088/1748-0221/9/11/T11005http://cds.cern.ch/record/2003206engAza, EleniMagistris, MMurtas, FPuddu, SSilari, MThe triple GEM detector as stray neutron monitorDetectors and Experimental TechniquesA triple GEM detector for low energy neutrons and high rejection of gamma background was tested at the CERF facility at CERN as stray neutron monitor. The detector was exposed to a wide neutron spectrum generated by a 120 GeV/c positively charged hadron beam hitting a copper target. The beam particle rate on target ranged over three orders of magnitude. The neutron count rate measured with the GEM could be linearly correlated with the beam intensity and also compared well with Monte Carlo simulations. The detector performance suggests that it can be used as an independent low energy neutron monitor at high-energy particle accelerator facilities.oai:inspirehep.net:13285892014
spellingShingle Detectors and Experimental Techniques
Aza, Eleni
Magistris, M
Murtas, F
Puddu, S
Silari, M
The triple GEM detector as stray neutron monitor
title The triple GEM detector as stray neutron monitor
title_full The triple GEM detector as stray neutron monitor
title_fullStr The triple GEM detector as stray neutron monitor
title_full_unstemmed The triple GEM detector as stray neutron monitor
title_short The triple GEM detector as stray neutron monitor
title_sort triple gem detector as stray neutron monitor
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1748-0221/9/11/T11005
http://cds.cern.ch/record/2003206
work_keys_str_mv AT azaeleni thetriplegemdetectorasstrayneutronmonitor
AT magistrism thetriplegemdetectorasstrayneutronmonitor
AT murtasf thetriplegemdetectorasstrayneutronmonitor
AT puddus thetriplegemdetectorasstrayneutronmonitor
AT silarim thetriplegemdetectorasstrayneutronmonitor
AT azaeleni triplegemdetectorasstrayneutronmonitor
AT magistrism triplegemdetectorasstrayneutronmonitor
AT murtasf triplegemdetectorasstrayneutronmonitor
AT puddus triplegemdetectorasstrayneutronmonitor
AT silarim triplegemdetectorasstrayneutronmonitor