Cargando…
A high precision radiation-tolerant LVDT conditioning module
Linear variable differential transformer (LVDT) position sensors are widely used in particle accelerators and nuclear plants, thanks to their properties of contact-less sensing, radiation tolerance, infinite resolution, good linearity and cost efficiency. Many applications require high reading accur...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2014.01.054 http://cds.cern.ch/record/2003217 |
_version_ | 1780946198609264640 |
---|---|
author | Masi, A Danzeca, S Losito, R Peronnard, P Secondo, R Spiezia, G |
author_facet | Masi, A Danzeca, S Losito, R Peronnard, P Secondo, R Spiezia, G |
author_sort | Masi, A |
collection | CERN |
description | Linear variable differential transformer (LVDT) position sensors are widely used in particle accelerators and nuclear plants, thanks to their properties of contact-less sensing, radiation tolerance, infinite resolution, good linearity and cost efficiency. Many applications require high reading accuracy, even in environments with high radiation levels, where the conditioning electronics must be located several hundred meters away from the sensor. Sometimes even at long distances the conditioning module is still exposed to ionizing radiation. Standard off-the-shelf electronic conditioning modules offer limited performances in terms of reading accuracy and long term stability already with short cables. A radiation tolerant stand-alone LVDT conditioning module has been developed using Commercial Off-The-Shelf (COTS) components. The reading of the sensor output voltages is based on a sine-fit algorithm digitally implemented on an FPGA ensuring few micrometers reading accuracy even with low signal-to-noise ratios. The algorithm validation and board architecture are described. A full metrological characterization of the module is reported and radiation tests results are discussed. |
id | oai-inspirehep.net-1334429 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | oai-inspirehep.net-13344292022-08-10T20:11:17Zdoi:10.1016/j.nima.2014.01.054http://cds.cern.ch/record/2003217engMasi, ADanzeca, SLosito, RPeronnard, PSecondo, RSpiezia, GA high precision radiation-tolerant LVDT conditioning moduleDetectors and Experimental TechniquesLinear variable differential transformer (LVDT) position sensors are widely used in particle accelerators and nuclear plants, thanks to their properties of contact-less sensing, radiation tolerance, infinite resolution, good linearity and cost efficiency. Many applications require high reading accuracy, even in environments with high radiation levels, where the conditioning electronics must be located several hundred meters away from the sensor. Sometimes even at long distances the conditioning module is still exposed to ionizing radiation. Standard off-the-shelf electronic conditioning modules offer limited performances in terms of reading accuracy and long term stability already with short cables. A radiation tolerant stand-alone LVDT conditioning module has been developed using Commercial Off-The-Shelf (COTS) components. The reading of the sensor output voltages is based on a sine-fit algorithm digitally implemented on an FPGA ensuring few micrometers reading accuracy even with low signal-to-noise ratios. The algorithm validation and board architecture are described. A full metrological characterization of the module is reported and radiation tests results are discussed.oai:inspirehep.net:13344292014 |
spellingShingle | Detectors and Experimental Techniques Masi, A Danzeca, S Losito, R Peronnard, P Secondo, R Spiezia, G A high precision radiation-tolerant LVDT conditioning module |
title | A high precision radiation-tolerant LVDT conditioning module |
title_full | A high precision radiation-tolerant LVDT conditioning module |
title_fullStr | A high precision radiation-tolerant LVDT conditioning module |
title_full_unstemmed | A high precision radiation-tolerant LVDT conditioning module |
title_short | A high precision radiation-tolerant LVDT conditioning module |
title_sort | high precision radiation-tolerant lvdt conditioning module |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2014.01.054 http://cds.cern.ch/record/2003217 |
work_keys_str_mv | AT masia ahighprecisionradiationtolerantlvdtconditioningmodule AT danzecas ahighprecisionradiationtolerantlvdtconditioningmodule AT lositor ahighprecisionradiationtolerantlvdtconditioningmodule AT peronnardp ahighprecisionradiationtolerantlvdtconditioningmodule AT secondor ahighprecisionradiationtolerantlvdtconditioningmodule AT spieziag ahighprecisionradiationtolerantlvdtconditioningmodule AT masia highprecisionradiationtolerantlvdtconditioningmodule AT danzecas highprecisionradiationtolerantlvdtconditioningmodule AT lositor highprecisionradiationtolerantlvdtconditioningmodule AT peronnardp highprecisionradiationtolerantlvdtconditioningmodule AT secondor highprecisionradiationtolerantlvdtconditioningmodule AT spieziag highprecisionradiationtolerantlvdtconditioningmodule |