Cargando…

Comparison of Tracking Simulation with Experiment on the GSI UNILAC

In the European framework “High Intensity Pulsed Proton Injector” (HIPPI), the 3D linac code comparison and benchmarking program with experiment have been initialed. PARMILA and HALODYN are involved in this work. Both of these codes have been developed and used for linac design and beam dynamics stu...

Descripción completa

Detalles Bibliográficos
Autores principales: Yin, Xuejun, Barth, Winfried, Bayer, Wolfgang, Groening, Lars, Hofmann, Ingo, Richter, Simone, Yaramyshev, Stepan, Franchi, Andrea, Sauer, Andreas
Lenguaje:eng
Publicado: 2013
Materias:
Acceso en línea:http://cds.cern.ch/record/2010139
Descripción
Sumario:In the European framework “High Intensity Pulsed Proton Injector” (HIPPI), the 3D linac code comparison and benchmarking program with experiment have been initialed. PARMILA and HALODYN are involved in this work. Both of these codes have been developed and used for linac design and beam dynamics studies. In this paper, we compare the simulation results with experiment results which was carried out on the UNILAC Alvarez DTL. And discuss physics aspects of the different linac design and beam dynamics simulation codes.