Cargando…

Correction of dead-time and pile-up in a detector array for constant and rapidly varying counting rates

The effect of dead-time and pile-up in counting experiments may become a significant source of uncertainty if not properly taken into account. Although analytical solutions to this problem have been proposed for simple set-ups with one or two detectors, these are limited when it comes to arrays wher...

Descripción completa

Detalles Bibliográficos
Autores principales: Guerrero, C, Cano-Ott, D, Mendoza, E, Wright, T
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2014.12.008
http://cds.cern.ch/record/2153717
_version_ 1780950642745933824
author Guerrero, C
Cano-Ott, D
Mendoza, E
Wright, T
author_facet Guerrero, C
Cano-Ott, D
Mendoza, E
Wright, T
author_sort Guerrero, C
collection CERN
description The effect of dead-time and pile-up in counting experiments may become a significant source of uncertainty if not properly taken into account. Although analytical solutions to this problem have been proposed for simple set-ups with one or two detectors, these are limited when it comes to arrays where time correlation between the detector modules is used, and also in situations of variable counting rates. In this paper we describe the dead-time and pile-up corrections applied to the n_TOF Total Absorption Calorimeter (TAC), a 4 π γ-ray detector made of 40 BaF 2 modules operating at the CERN n_TOF facility. Our method is based on the simulation of the complete signal detection and event reconstruction processes and can be applied as well in the case of rapidly varying counting rates. The method is discussed in detail and then we present its successful application to the particular case of the measurement of 238 U(n, γ ) reactions with the TAC detector.
id oai-inspirehep.net-1340398
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling oai-inspirehep.net-13403982019-09-30T06:29:59Zdoi:10.1016/j.nima.2014.12.008http://cds.cern.ch/record/2153717engGuerrero, CCano-Ott, DMendoza, EWright, TCorrection of dead-time and pile-up in a detector array for constant and rapidly varying counting ratesDetectors and Experimental TechniquesThe effect of dead-time and pile-up in counting experiments may become a significant source of uncertainty if not properly taken into account. Although analytical solutions to this problem have been proposed for simple set-ups with one or two detectors, these are limited when it comes to arrays where time correlation between the detector modules is used, and also in situations of variable counting rates. In this paper we describe the dead-time and pile-up corrections applied to the n_TOF Total Absorption Calorimeter (TAC), a 4 π γ-ray detector made of 40 BaF 2 modules operating at the CERN n_TOF facility. Our method is based on the simulation of the complete signal detection and event reconstruction processes and can be applied as well in the case of rapidly varying counting rates. The method is discussed in detail and then we present its successful application to the particular case of the measurement of 238 U(n, γ ) reactions with the TAC detector.oai:inspirehep.net:13403982015
spellingShingle Detectors and Experimental Techniques
Guerrero, C
Cano-Ott, D
Mendoza, E
Wright, T
Correction of dead-time and pile-up in a detector array for constant and rapidly varying counting rates
title Correction of dead-time and pile-up in a detector array for constant and rapidly varying counting rates
title_full Correction of dead-time and pile-up in a detector array for constant and rapidly varying counting rates
title_fullStr Correction of dead-time and pile-up in a detector array for constant and rapidly varying counting rates
title_full_unstemmed Correction of dead-time and pile-up in a detector array for constant and rapidly varying counting rates
title_short Correction of dead-time and pile-up in a detector array for constant and rapidly varying counting rates
title_sort correction of dead-time and pile-up in a detector array for constant and rapidly varying counting rates
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2014.12.008
http://cds.cern.ch/record/2153717
work_keys_str_mv AT guerreroc correctionofdeadtimeandpileupinadetectorarrayforconstantandrapidlyvaryingcountingrates
AT canoottd correctionofdeadtimeandpileupinadetectorarrayforconstantandrapidlyvaryingcountingrates
AT mendozae correctionofdeadtimeandpileupinadetectorarrayforconstantandrapidlyvaryingcountingrates
AT wrightt correctionofdeadtimeandpileupinadetectorarrayforconstantandrapidlyvaryingcountingrates