High-precision half-life measurement for the isospin T=1/2 mirror β+ decay of $^{21}$Na

The half-life of the isospin T=1/2 mirror β+ decay of Na21 was measured at the GANIL-SPIRAL radioactive ion beam facility to be T1/2=22.422 (10) s, a result that is more than a factor of 5 times more precise than the previous world average, with a resulting ft value that is now two times more precis...

Descripción completa

Detalles Bibliográficos
Autores principales: Grinyer, J, Grinyer, G F, Babo, M, Bouzomita, H, Chauveau, P, Delahaye, P, Dubois, M, Frigot, R, Jardin, P, Leboucher, C, Maunoury, L, Seiffert, C, Thomas, J C, Traykov, E
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:https://dx.doi.org/10.1103/PhysRevC.91.032501
http://cds.cern.ch/record/2153731
_version_ 1780950646464184320
author Grinyer, J
Grinyer, G F
Babo, M
Bouzomita, H
Chauveau, P
Delahaye, P
Dubois, M
Frigot, R
Jardin, P
Leboucher, C
Maunoury, L
Seiffert, C
Thomas, J C
Traykov, E
author_facet Grinyer, J
Grinyer, G F
Babo, M
Bouzomita, H
Chauveau, P
Delahaye, P
Dubois, M
Frigot, R
Jardin, P
Leboucher, C
Maunoury, L
Seiffert, C
Thomas, J C
Traykov, E
author_sort Grinyer, J
collection CERN
description The half-life of the isospin T=1/2 mirror β+ decay of Na21 was measured at the GANIL-SPIRAL radioactive ion beam facility to be T1/2=22.422 (10) s, a result that is more than a factor of 5 times more precise than the previous world average, with a resulting ft value that is now two times more precise. The precision of this new result implies that the half-life is no longer the dominant source of uncertainty in the Ft value used in the calculation of Vud from mirror decays to test the conserved vector current hypothesis of the standard model. The value of Vud deduced from mirror decays using the new half-life result is now in better agreement with the Vud derived from T=1 superallowed 0+ to 0+ transitions.
id oai-inspirehep.net-1356186
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling oai-inspirehep.net-13561862022-08-10T13:07:22Zdoi:10.1103/PhysRevC.91.032501http://cds.cern.ch/record/2153731engGrinyer, JGrinyer, G FBabo, MBouzomita, HChauveau, PDelahaye, PDubois, MFrigot, RJardin, PLeboucher, CMaunoury, LSeiffert, CThomas, J CTraykov, EHigh-precision half-life measurement for the isospin T=1/2 mirror β+ decay of $^{21}$NaNuclear Physics - ExperimentThe half-life of the isospin T=1/2 mirror β+ decay of Na21 was measured at the GANIL-SPIRAL radioactive ion beam facility to be T1/2=22.422 (10) s, a result that is more than a factor of 5 times more precise than the previous world average, with a resulting ft value that is now two times more precise. The precision of this new result implies that the half-life is no longer the dominant source of uncertainty in the Ft value used in the calculation of Vud from mirror decays to test the conserved vector current hypothesis of the standard model. The value of Vud deduced from mirror decays using the new half-life result is now in better agreement with the Vud derived from T=1 superallowed 0+ to 0+ transitions.oai:inspirehep.net:13561862015
spellingShingle Nuclear Physics - Experiment
Grinyer, J
Grinyer, G F
Babo, M
Bouzomita, H
Chauveau, P
Delahaye, P
Dubois, M
Frigot, R
Jardin, P
Leboucher, C
Maunoury, L
Seiffert, C
Thomas, J C
Traykov, E
High-precision half-life measurement for the isospin T=1/2 mirror β+ decay of $^{21}$Na
title High-precision half-life measurement for the isospin T=1/2 mirror β+ decay of $^{21}$Na
title_full High-precision half-life measurement for the isospin T=1/2 mirror β+ decay of $^{21}$Na
title_fullStr High-precision half-life measurement for the isospin T=1/2 mirror β+ decay of $^{21}$Na
title_full_unstemmed High-precision half-life measurement for the isospin T=1/2 mirror β+ decay of $^{21}$Na
title_short High-precision half-life measurement for the isospin T=1/2 mirror β+ decay of $^{21}$Na
title_sort high-precision half-life measurement for the isospin t=1/2 mirror β+ decay of $^{21}$na
topic Nuclear Physics - Experiment
url https://dx.doi.org/10.1103/PhysRevC.91.032501
http://cds.cern.ch/record/2153731
work_keys_str_mv AT grinyerj highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT grinyergf highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT babom highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT bouzomitah highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT chauveaup highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT delahayep highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT duboism highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT frigotr highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT jardinp highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT leboucherc highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT maunouryl highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT seiffertc highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT thomasjc highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na
AT traykove highprecisionhalflifemeasurementfortheisospint12mirrorbdecayof21na