Cargando…
Development of a custom on-line ultrasonic vapour analyzer and flow meter for the ATLAS inner detector, with application to Cherenkov and gaseous charged particle detectors
Precision sound velocity measurements can simultaneously determine binary gas composition and flow. We have developed an analyzer with custom microcontroller-based electronics, currently used in the ATLAS Detector Control System, with numerous potential applications. Three instruments monitor C(3)F(...
Autores principales: | Alhroob, M, Bates, R, Battistin, M, Berry, S, Bitadze, A, Bonneau, P, Bousson, N, Boyd, G, Bozza, G, Crespo-Lopez, O, Degeorge, C, Deterre, C, DiGirolamo, B, Doubek, M, Favre, G, Godlewski, J, Hallewell, G, Hasib, A, Katunin, S, Langevin, N, Lombard, D, Mathieu, M, McMahon, S, Nagai, K, O'Rourke, A, Pearson, B, Robinson, D, Rossi, C, Rozanov, A, Strauss, M, Vacek, V, Zwalinski, L |
---|---|
Lenguaje: | eng |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/10/03/C03045 http://cds.cern.ch/record/2158975 |
Ejemplares similares
-
Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors
por: Bates, R., et al.
Publicado: (2012) -
A combined ultrasonic flow meter and binary vapour mixture analyzer for the ATLAS silicon tracker
por: Bates, R., et al.
Publicado: (2012) -
A Custom Online Ultrasonic Gas Mixture Analyzer With Simultaneous Flowmetry, Developed for the Upgraded Evaporative Cooling System of the ATLAS Silicon Tracker
por: Bates, R, et al.
Publicado: (2014) -
Implementation of an ultrasonic instrument for simultaneous mixture and flow analysis of binary gas systems
por: Alhroob, M, et al.
Publicado: (2015) -
Micropattern gaseous photon detectors for Cherenkov imaging counters
por: Alexeev, M, et al.