Cargando…

The Phase-1 upgrade of the CMS silicon pixel detector

The present CMS pixel detector will be replaced in the shutdown period 2016/17 by an upgraded version due to the following reasons: increased luminosity at reduced bunch spacing ( from 7 x 10 33 cm - 2 s - 1 at 50 ns bunch spacing to 2 x 10 34 cm - 2 s - 1 at 25 ns bunch spacing) in the LHC , and ra...

Descripción completa

Detalles Bibliográficos
Autor principal: Menichelli, Mauro
Lenguaje:eng
Publicado: SISSA 2015
Materias:
Acceso en línea:https://dx.doi.org/10.22323/1.189.0011
http://cds.cern.ch/record/2158976
_version_ 1780950807061987328
author Menichelli, Mauro
author_facet Menichelli, Mauro
author_sort Menichelli, Mauro
collection CERN
description The present CMS pixel detector will be replaced in the shutdown period 2016/17 by an upgraded version due to the following reasons: increased luminosity at reduced bunch spacing ( from 7 x 10 33 cm - 2 s - 1 at 50 ns bunch spacing to 2 x 10 34 cm - 2 s - 1 at 25 ns bunch spacing) in the LHC , and radiation damage effects that will significantly degrade the present detector. The new upgraded detector will have higher tracking efficiency and lower mass with four barrel layer and three forward/backward disks to provide higher hit pixel coverage out to pseudorapidities of ±2.5. In this paper we will describe the new pixel detector focus ing mostly on the barrel detector design, construction and expected performances
id oai-inspirehep.net-1356833
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
publisher SISSA
record_format invenio
spelling oai-inspirehep.net-13568332019-10-15T15:21:51Zdoi:10.22323/1.189.0011http://cds.cern.ch/record/2158976engMenichelli, MauroThe Phase-1 upgrade of the CMS silicon pixel detectorDetectors and Experimental TechniquesThe present CMS pixel detector will be replaced in the shutdown period 2016/17 by an upgraded version due to the following reasons: increased luminosity at reduced bunch spacing ( from 7 x 10 33 cm - 2 s - 1 at 50 ns bunch spacing to 2 x 10 34 cm - 2 s - 1 at 25 ns bunch spacing) in the LHC , and radiation damage effects that will significantly degrade the present detector. The new upgraded detector will have higher tracking efficiency and lower mass with four barrel layer and three forward/backward disks to provide higher hit pixel coverage out to pseudorapidities of ±2.5. In this paper we will describe the new pixel detector focus ing mostly on the barrel detector design, construction and expected performancesSISSAoai:inspirehep.net:13568332015
spellingShingle Detectors and Experimental Techniques
Menichelli, Mauro
The Phase-1 upgrade of the CMS silicon pixel detector
title The Phase-1 upgrade of the CMS silicon pixel detector
title_full The Phase-1 upgrade of the CMS silicon pixel detector
title_fullStr The Phase-1 upgrade of the CMS silicon pixel detector
title_full_unstemmed The Phase-1 upgrade of the CMS silicon pixel detector
title_short The Phase-1 upgrade of the CMS silicon pixel detector
title_sort phase-1 upgrade of the cms silicon pixel detector
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.22323/1.189.0011
http://cds.cern.ch/record/2158976
work_keys_str_mv AT menichellimauro thephase1upgradeofthecmssiliconpixeldetector
AT menichellimauro phase1upgradeofthecmssiliconpixeldetector