Cargando…
The Phase-1 upgrade of the CMS silicon pixel detector
The present CMS pixel detector will be replaced in the shutdown period 2016/17 by an upgraded version due to the following reasons: increased luminosity at reduced bunch spacing ( from 7 x 10 33 cm - 2 s - 1 at 50 ns bunch spacing to 2 x 10 34 cm - 2 s - 1 at 25 ns bunch spacing) in the LHC , and ra...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
SISSA
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.22323/1.189.0011 http://cds.cern.ch/record/2158976 |
_version_ | 1780950807061987328 |
---|---|
author | Menichelli, Mauro |
author_facet | Menichelli, Mauro |
author_sort | Menichelli, Mauro |
collection | CERN |
description | The present CMS pixel detector will be replaced in the shutdown period 2016/17 by an upgraded version due to the following reasons: increased luminosity at reduced bunch spacing ( from 7 x 10 33 cm - 2 s - 1 at 50 ns bunch spacing to 2 x 10 34 cm - 2 s - 1 at 25 ns bunch spacing) in the LHC , and radiation damage effects that will significantly degrade the present detector. The new upgraded detector will have higher tracking efficiency and lower mass with four barrel layer and three forward/backward disks to provide higher hit pixel coverage out to pseudorapidities of ±2.5. In this paper we will describe the new pixel detector focus ing mostly on the barrel detector design, construction and expected performances |
id | oai-inspirehep.net-1356833 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
publisher | SISSA |
record_format | invenio |
spelling | oai-inspirehep.net-13568332019-10-15T15:21:51Zdoi:10.22323/1.189.0011http://cds.cern.ch/record/2158976engMenichelli, MauroThe Phase-1 upgrade of the CMS silicon pixel detectorDetectors and Experimental TechniquesThe present CMS pixel detector will be replaced in the shutdown period 2016/17 by an upgraded version due to the following reasons: increased luminosity at reduced bunch spacing ( from 7 x 10 33 cm - 2 s - 1 at 50 ns bunch spacing to 2 x 10 34 cm - 2 s - 1 at 25 ns bunch spacing) in the LHC , and radiation damage effects that will significantly degrade the present detector. The new upgraded detector will have higher tracking efficiency and lower mass with four barrel layer and three forward/backward disks to provide higher hit pixel coverage out to pseudorapidities of ±2.5. In this paper we will describe the new pixel detector focus ing mostly on the barrel detector design, construction and expected performancesSISSAoai:inspirehep.net:13568332015 |
spellingShingle | Detectors and Experimental Techniques Menichelli, Mauro The Phase-1 upgrade of the CMS silicon pixel detector |
title | The Phase-1 upgrade of the CMS silicon pixel detector |
title_full | The Phase-1 upgrade of the CMS silicon pixel detector |
title_fullStr | The Phase-1 upgrade of the CMS silicon pixel detector |
title_full_unstemmed | The Phase-1 upgrade of the CMS silicon pixel detector |
title_short | The Phase-1 upgrade of the CMS silicon pixel detector |
title_sort | phase-1 upgrade of the cms silicon pixel detector |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.22323/1.189.0011 http://cds.cern.ch/record/2158976 |
work_keys_str_mv | AT menichellimauro thephase1upgradeofthecmssiliconpixeldetector AT menichellimauro phase1upgradeofthecmssiliconpixeldetector |