Cargando…

FBCT fast intensity measurement using TRIC cards

At the CERN PS complex, precise fast intensity measurements are very important in order to optimize the transfer efficiencies between the different accelerators. Over the last two years a complete renovation has been ongoing, where the old electronics, based on analogue integrators, have been replac...

Descripción completa

Detalles Bibliográficos
Autores principales: Allica, J C, Andersen, M, Belohrad, D, Jensen, L, Lenardon, F, SØby, L
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/10/04/C04016
http://cds.cern.ch/record/2158989
_version_ 1780950810128023552
author Allica, J C
Andersen, M
Belohrad, D
Jensen, L
Lenardon, F
SØby, L
author_facet Allica, J C
Andersen, M
Belohrad, D
Jensen, L
Lenardon, F
SØby, L
author_sort Allica, J C
collection CERN
description At the CERN PS complex, precise fast intensity measurements are very important in order to optimize the transfer efficiencies between the different accelerators. Over the last two years a complete renovation has been ongoing, where the old electronics, based on analogue integrators, have been replaced by a fully digital system enclosed in a single VME based card. This new system called TRIC (Transformer Integration Card) is based on a 12 bit, 212 MS/s ADC and an FPGA for the signal processing. Also located on the same board one finds a 250 V/1.5 W DCDC converter used to generate precise calibration pulses.
id oai-inspirehep.net-1362118
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling oai-inspirehep.net-13621182019-09-30T06:29:59Zdoi:10.1088/1748-0221/10/04/C04016http://cds.cern.ch/record/2158989engAllica, J CAndersen, MBelohrad, DJensen, LLenardon, FSØby, LFBCT fast intensity measurement using TRIC cardsDetectors and Experimental TechniquesAt the CERN PS complex, precise fast intensity measurements are very important in order to optimize the transfer efficiencies between the different accelerators. Over the last two years a complete renovation has been ongoing, where the old electronics, based on analogue integrators, have been replaced by a fully digital system enclosed in a single VME based card. This new system called TRIC (Transformer Integration Card) is based on a 12 bit, 212 MS/s ADC and an FPGA for the signal processing. Also located on the same board one finds a 250 V/1.5 W DCDC converter used to generate precise calibration pulses.oai:inspirehep.net:13621182015
spellingShingle Detectors and Experimental Techniques
Allica, J C
Andersen, M
Belohrad, D
Jensen, L
Lenardon, F
SØby, L
FBCT fast intensity measurement using TRIC cards
title FBCT fast intensity measurement using TRIC cards
title_full FBCT fast intensity measurement using TRIC cards
title_fullStr FBCT fast intensity measurement using TRIC cards
title_full_unstemmed FBCT fast intensity measurement using TRIC cards
title_short FBCT fast intensity measurement using TRIC cards
title_sort fbct fast intensity measurement using tric cards
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1748-0221/10/04/C04016
http://cds.cern.ch/record/2158989
work_keys_str_mv AT allicajc fbctfastintensitymeasurementusingtriccards
AT andersenm fbctfastintensitymeasurementusingtriccards
AT belohradd fbctfastintensitymeasurementusingtriccards
AT jensenl fbctfastintensitymeasurementusingtriccards
AT lenardonf fbctfastintensitymeasurementusingtriccards
AT søbyl fbctfastintensitymeasurementusingtriccards