Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning
The transverse emittance at the output of the REX-ISOLDE normal conducting linac has been measured at different energies in order to characterise the beam at injection to the future HIE-ISOLDE superconducting linac. The measurements were done with low intensity stable beams (~0.5 enA) in order to av...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2062602 |
_version_ | 1780948554304454656 |
---|---|
author | Voulot, Didier Fraser, Matthew Lanaia, Davide Olsson, Teresia |
author_facet | Voulot, Didier Fraser, Matthew Lanaia, Davide Olsson, Teresia |
author_sort | Voulot, Didier |
collection | CERN |
description | The transverse emittance at the output of the REX-ISOLDE normal conducting linac has been measured at different energies in order to characterise the beam at injection to the future HIE-ISOLDE superconducting linac. The measurements were done with low intensity stable beams (~0.5 enA) in order to avoid compensation effects in the EBIS ion source and obtain representative measurements of the radioactive ion beam emittance. Emittances were measured using a slit-grid emittance meter and compared with results obtained with a quadrupole-scan (three-gradient) method. An analysis of the background suppression is presented and possible source of errors for both type of measurements are discussed. |
id | oai-inspirehep.net-1363442 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | oai-inspirehep.net-13634422019-09-30T06:29:59Zhttp://cds.cern.ch/record/2062602engVoulot, DidierFraser, MatthewLanaia, DavideOlsson, TeresiaTransverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE CommissioningAccelerators and Storage RingsThe transverse emittance at the output of the REX-ISOLDE normal conducting linac has been measured at different energies in order to characterise the beam at injection to the future HIE-ISOLDE superconducting linac. The measurements were done with low intensity stable beams (~0.5 enA) in order to avoid compensation effects in the EBIS ion source and obtain representative measurements of the radioactive ion beam emittance. Emittances were measured using a slit-grid emittance meter and compared with results obtained with a quadrupole-scan (three-gradient) method. An analysis of the background suppression is presented and possible source of errors for both type of measurements are discussed.CERN-ACC-2014-382oai:inspirehep.net:13634422014 |
spellingShingle | Accelerators and Storage Rings Voulot, Didier Fraser, Matthew Lanaia, Davide Olsson, Teresia Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning |
title | Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning |
title_full | Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning |
title_fullStr | Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning |
title_full_unstemmed | Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning |
title_short | Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning |
title_sort | transverse emittance measurements of the rex-isolde beams in preparation for the hie-isolde commissioning |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/2062602 |
work_keys_str_mv | AT voulotdidier transverseemittancemeasurementsoftherexisoldebeamsinpreparationforthehieisoldecommissioning AT frasermatthew transverseemittancemeasurementsoftherexisoldebeamsinpreparationforthehieisoldecommissioning AT lanaiadavide transverseemittancemeasurementsoftherexisoldebeamsinpreparationforthehieisoldecommissioning AT olssonteresia transverseemittancemeasurementsoftherexisoldebeamsinpreparationforthehieisoldecommissioning |