Cargando…

Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning

The transverse emittance at the output of the REX-ISOLDE normal conducting linac has been measured at different energies in order to characterise the beam at injection to the future HIE-ISOLDE superconducting linac. The measurements were done with low intensity stable beams (~0.5 enA) in order to av...

Descripción completa

Detalles Bibliográficos
Autores principales: Voulot, Didier, Fraser, Matthew, Lanaia, Davide, Olsson, Teresia
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/2062602
_version_ 1780948554304454656
author Voulot, Didier
Fraser, Matthew
Lanaia, Davide
Olsson, Teresia
author_facet Voulot, Didier
Fraser, Matthew
Lanaia, Davide
Olsson, Teresia
author_sort Voulot, Didier
collection CERN
description The transverse emittance at the output of the REX-ISOLDE normal conducting linac has been measured at different energies in order to characterise the beam at injection to the future HIE-ISOLDE superconducting linac. The measurements were done with low intensity stable beams (~0.5 enA) in order to avoid compensation effects in the EBIS ion source and obtain representative measurements of the radioactive ion beam emittance. Emittances were measured using a slit-grid emittance meter and compared with results obtained with a quadrupole-scan (three-gradient) method. An analysis of the background suppression is presented and possible source of errors for both type of measurements are discussed.
id oai-inspirehep.net-1363442
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling oai-inspirehep.net-13634422019-09-30T06:29:59Zhttp://cds.cern.ch/record/2062602engVoulot, DidierFraser, MatthewLanaia, DavideOlsson, TeresiaTransverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE CommissioningAccelerators and Storage RingsThe transverse emittance at the output of the REX-ISOLDE normal conducting linac has been measured at different energies in order to characterise the beam at injection to the future HIE-ISOLDE superconducting linac. The measurements were done with low intensity stable beams (~0.5 enA) in order to avoid compensation effects in the EBIS ion source and obtain representative measurements of the radioactive ion beam emittance. Emittances were measured using a slit-grid emittance meter and compared with results obtained with a quadrupole-scan (three-gradient) method. An analysis of the background suppression is presented and possible source of errors for both type of measurements are discussed.CERN-ACC-2014-382oai:inspirehep.net:13634422014
spellingShingle Accelerators and Storage Rings
Voulot, Didier
Fraser, Matthew
Lanaia, Davide
Olsson, Teresia
Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning
title Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning
title_full Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning
title_fullStr Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning
title_full_unstemmed Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning
title_short Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning
title_sort transverse emittance measurements of the rex-isolde beams in preparation for the hie-isolde commissioning
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/2062602
work_keys_str_mv AT voulotdidier transverseemittancemeasurementsoftherexisoldebeamsinpreparationforthehieisoldecommissioning
AT frasermatthew transverseemittancemeasurementsoftherexisoldebeamsinpreparationforthehieisoldecommissioning
AT lanaiadavide transverseemittancemeasurementsoftherexisoldebeamsinpreparationforthehieisoldecommissioning
AT olssonteresia transverseemittancemeasurementsoftherexisoldebeamsinpreparationforthehieisoldecommissioning