Cargando…

Proton and Carbon Linacs for Hadron Therapy

Beams of 200 MeV protons and 400 MeV/u fully stripped carbon ions are used for the treatment of solid tumours seated at a maximum depth of 27 cm. More than 100’000 patients have been treated with proton beams and more than 10’000 with carbon ions. Very low proton currents - of the order of 1 nA - ar...

Descripción completa

Detalles Bibliográficos
Autores principales: Degiovanni, Alberto, Amaldi, Ugo
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:http://cds.cern.ch/record/2062622
_version_ 1780948558613053440
author Degiovanni, Alberto
Amaldi, Ugo
author_facet Degiovanni, Alberto
Amaldi, Ugo
author_sort Degiovanni, Alberto
collection CERN
description Beams of 200 MeV protons and 400 MeV/u fully stripped carbon ions are used for the treatment of solid tumours seated at a maximum depth of 27 cm. More than 100’000 patients have been treated with proton beams and more than 10’000 with carbon ions. Very low proton currents - of the order of 1 nA - are enough to deliver the typical dose of 2 Gy/l in one minute. In the case of carbon ions the currents are of the order of 0.1-0.2 nA. For this reason 3 GHz linacs are well suited in spite of the small apertures and low duty cycle. The main advantage of linacs, pulsing at 200-400 Hz, is that the output energy can be continuously varied pulse-by-pulse and in 2-3 min a moving tumour target can be covered about 10 times by deposing the dose in many thousands of ‘spots’. High frequency hadron therapy linacs have been studied in the last 20 years and are now being built as hearts of proton therapy centres, while carbon ion linacs are still in the designing stage. At present the main challenges are the reduction of the footprint of compact ‘single-room’ proton machines and the power efficiency of dual proton and carbon ions ‘multi-room’ facilities.
id oai-inspirehep.net-1363637
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling oai-inspirehep.net-13636372019-09-30T06:29:59Zhttp://cds.cern.ch/record/2062622engDegiovanni, AlbertoAmaldi, UgoProton and Carbon Linacs for Hadron TherapyAccelerators and Storage RingsBeams of 200 MeV protons and 400 MeV/u fully stripped carbon ions are used for the treatment of solid tumours seated at a maximum depth of 27 cm. More than 100’000 patients have been treated with proton beams and more than 10’000 with carbon ions. Very low proton currents - of the order of 1 nA - are enough to deliver the typical dose of 2 Gy/l in one minute. In the case of carbon ions the currents are of the order of 0.1-0.2 nA. For this reason 3 GHz linacs are well suited in spite of the small apertures and low duty cycle. The main advantage of linacs, pulsing at 200-400 Hz, is that the output energy can be continuously varied pulse-by-pulse and in 2-3 min a moving tumour target can be covered about 10 times by deposing the dose in many thousands of ‘spots’. High frequency hadron therapy linacs have been studied in the last 20 years and are now being built as hearts of proton therapy centres, while carbon ion linacs are still in the designing stage. At present the main challenges are the reduction of the footprint of compact ‘single-room’ proton machines and the power efficiency of dual proton and carbon ions ‘multi-room’ facilities.CERN-ACC-2014-362oai:inspirehep.net:13636372014
spellingShingle Accelerators and Storage Rings
Degiovanni, Alberto
Amaldi, Ugo
Proton and Carbon Linacs for Hadron Therapy
title Proton and Carbon Linacs for Hadron Therapy
title_full Proton and Carbon Linacs for Hadron Therapy
title_fullStr Proton and Carbon Linacs for Hadron Therapy
title_full_unstemmed Proton and Carbon Linacs for Hadron Therapy
title_short Proton and Carbon Linacs for Hadron Therapy
title_sort proton and carbon linacs for hadron therapy
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/2062622
work_keys_str_mv AT degiovannialberto protonandcarbonlinacsforhadrontherapy
AT amaldiugo protonandcarbonlinacsforhadrontherapy