Beam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectors

We present results of beam tests of charged particle detectors based on single-crystal and poly-crystalline Chemical Vapor Deposition (CVD) diamond. We measured the signal pulse height dependence on the particle flux. The detectors were tested over a range of particle fluxes from 2 kHz/cm(2) to 20 M...

Descripción completa

Detalles Bibliográficos
Autor principal: Wallny, R
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/10/07/C07009
http://cds.cern.ch/record/2159123
_version_ 1780950839282630656
author Wallny, R
author_facet Wallny, R
author_sort Wallny, R
collection CERN
description We present results of beam tests of charged particle detectors based on single-crystal and poly-crystalline Chemical Vapor Deposition (CVD) diamond. We measured the signal pulse height dependence on the particle flux. The detectors were tested over a range of particle fluxes from 2 kHz/cm(2) to 20 MHz/cm(2). The pulse height of the sensors was measured with pad and pixel readout electronics. The pulse height of the non-irradiated single-crystal CVD diamond pad sensors was stable with respect to flux, while the pulse height of irradiated single-crystal CVD diamond pad sensors decreased with increasing particle flux. The pulse height of the non-irradiated single-crystal CVD diamond pixel detectors decreased slightly with increasing particle flux while the pulse height of the irradiated single-crystal CVD diamond pixel detectors decreased significantly with increasing particle flux. The observed sensitivity to flux is similar in both the diamond pad sensors constructed using diamonds from the Pixel Luminosity Telescope (PLT) irradiated during its pilot run in the Compact Muon Solenoid (CMS) detector and in neutron irradiated diamond pad sensors from the same manufacturer irradiated to the same fluence of neutrons. The pulse height for irradiated poly-crystalline CVD diamond pad sensors proved to be stable with respect to particle flux.
id oai-inspirehep.net-1383034
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling oai-inspirehep.net-13830342019-09-30T06:29:59Zdoi:10.1088/1748-0221/10/07/C07009http://cds.cern.ch/record/2159123engWallny, RBeam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectorsDetectors and Experimental TechniquesWe present results of beam tests of charged particle detectors based on single-crystal and poly-crystalline Chemical Vapor Deposition (CVD) diamond. We measured the signal pulse height dependence on the particle flux. The detectors were tested over a range of particle fluxes from 2 kHz/cm(2) to 20 MHz/cm(2). The pulse height of the sensors was measured with pad and pixel readout electronics. The pulse height of the non-irradiated single-crystal CVD diamond pad sensors was stable with respect to flux, while the pulse height of irradiated single-crystal CVD diamond pad sensors decreased with increasing particle flux. The pulse height of the non-irradiated single-crystal CVD diamond pixel detectors decreased slightly with increasing particle flux while the pulse height of the irradiated single-crystal CVD diamond pixel detectors decreased significantly with increasing particle flux. The observed sensitivity to flux is similar in both the diamond pad sensors constructed using diamonds from the Pixel Luminosity Telescope (PLT) irradiated during its pilot run in the Compact Muon Solenoid (CMS) detector and in neutron irradiated diamond pad sensors from the same manufacturer irradiated to the same fluence of neutrons. The pulse height for irradiated poly-crystalline CVD diamond pad sensors proved to be stable with respect to particle flux.oai:inspirehep.net:13830342015
spellingShingle Detectors and Experimental Techniques
Wallny, R
Beam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectors
title Beam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectors
title_full Beam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectors
title_fullStr Beam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectors
title_full_unstemmed Beam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectors
title_short Beam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectors
title_sort beam test results of the dependence of signal size on incident particle flux in diamond pixel and pad detectors
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1748-0221/10/07/C07009
http://cds.cern.ch/record/2159123
work_keys_str_mv AT wallnyr beamtestresultsofthedependenceofsignalsizeonincidentparticlefluxindiamondpixelandpaddetectors