Cargando…
Helium Inventory Management and Losses for LHC Cryogenics: Strategy and Results for Run 1
The Large Hadron Collider (LHC) cryogenic system requires an unprecedented helium inventory of 130 tons. If the operational availability for physics was clearly set first priority for run 1 (from first cool-down to long shut-down 1), specific measures were taken from the beginning towards the best r...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.phpro.2015.06.012 http://cds.cern.ch/record/2103417 |
_version_ | 1780948804400316416 |
---|---|
author | Claudet, S Brodzinski, K Darras, V Delikaris, D Duret-Bourgoz, E Ferlin, G Tavian, L |
author_facet | Claudet, S Brodzinski, K Darras, V Delikaris, D Duret-Bourgoz, E Ferlin, G Tavian, L |
author_sort | Claudet, S |
collection | CERN |
description | The Large Hadron Collider (LHC) cryogenic system requires an unprecedented helium inventory of 130 tons. If the operational availability for physics was clearly set first priority for run 1 (from first cool-down to long shut-down 1), specific measures were taken from the beginning towards the best rational use of helium during this period. Additional storage capacity was installed to match schedule constraints. Tools were developed to monitor the inventory. Operational achievements were analyzed and corrections applied.After recalling the strategy defined for managing the helium inventory and associated infrastructure, tools and methods developed, the achieved results and perspectives will be presented. |
id | oai-inspirehep.net-1384349 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
record_format | invenio |
spelling | oai-inspirehep.net-13843492022-08-10T13:04:58Zdoi:10.1016/j.phpro.2015.06.012http://cds.cern.ch/record/2103417engClaudet, SBrodzinski, KDarras, VDelikaris, DDuret-Bourgoz, EFerlin, GTavian, LHelium Inventory Management and Losses for LHC Cryogenics: Strategy and Results for Run 1Accelerators and Storage RingsThe Large Hadron Collider (LHC) cryogenic system requires an unprecedented helium inventory of 130 tons. If the operational availability for physics was clearly set first priority for run 1 (from first cool-down to long shut-down 1), specific measures were taken from the beginning towards the best rational use of helium during this period. Additional storage capacity was installed to match schedule constraints. Tools were developed to monitor the inventory. Operational achievements were analyzed and corrections applied.After recalling the strategy defined for managing the helium inventory and associated infrastructure, tools and methods developed, the achieved results and perspectives will be presented.oai:inspirehep.net:13843492015 |
spellingShingle | Accelerators and Storage Rings Claudet, S Brodzinski, K Darras, V Delikaris, D Duret-Bourgoz, E Ferlin, G Tavian, L Helium Inventory Management and Losses for LHC Cryogenics: Strategy and Results for Run 1 |
title | Helium Inventory Management and Losses for LHC Cryogenics: Strategy and Results for Run 1 |
title_full | Helium Inventory Management and Losses for LHC Cryogenics: Strategy and Results for Run 1 |
title_fullStr | Helium Inventory Management and Losses for LHC Cryogenics: Strategy and Results for Run 1 |
title_full_unstemmed | Helium Inventory Management and Losses for LHC Cryogenics: Strategy and Results for Run 1 |
title_short | Helium Inventory Management and Losses for LHC Cryogenics: Strategy and Results for Run 1 |
title_sort | helium inventory management and losses for lhc cryogenics: strategy and results for run 1 |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1016/j.phpro.2015.06.012 http://cds.cern.ch/record/2103417 |
work_keys_str_mv | AT claudets heliuminventorymanagementandlossesforlhccryogenicsstrategyandresultsforrun1 AT brodzinskik heliuminventorymanagementandlossesforlhccryogenicsstrategyandresultsforrun1 AT darrasv heliuminventorymanagementandlossesforlhccryogenicsstrategyandresultsforrun1 AT delikarisd heliuminventorymanagementandlossesforlhccryogenicsstrategyandresultsforrun1 AT duretbourgoze heliuminventorymanagementandlossesforlhccryogenicsstrategyandresultsforrun1 AT ferling heliuminventorymanagementandlossesforlhccryogenicsstrategyandresultsforrun1 AT tavianl heliuminventorymanagementandlossesforlhccryogenicsstrategyandresultsforrun1 |