Cargando…

High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33

Background: Measurements of the ft values for T=1/2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the ft values are...

Descripción completa

Detalles Bibliográficos
Autores principales: Grinyer, J, Grinyer, G F, Babo, M, Bouzomita, H, Chauveau, P, Delahaye, P, Dubois, M, Frigot, R, Jardin, P, Leboucher, C, Maunoury, L, Seiffert, C, Thomas, J C, Traykov, E
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:https://dx.doi.org/10.1103/PhysRevC.92.045503
http://cds.cern.ch/record/2194350
_version_ 1780951052742295552
author Grinyer, J
Grinyer, G F
Babo, M
Bouzomita, H
Chauveau, P
Delahaye, P
Dubois, M
Frigot, R
Jardin, P
Leboucher, C
Maunoury, L
Seiffert, C
Thomas, J C
Traykov, E
author_facet Grinyer, J
Grinyer, G F
Babo, M
Bouzomita, H
Chauveau, P
Delahaye, P
Dubois, M
Frigot, R
Jardin, P
Leboucher, C
Maunoury, L
Seiffert, C
Thomas, J C
Traykov, E
author_sort Grinyer, J
collection CERN
description Background: Measurements of the ft values for T=1/2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the ft values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T=1/2β+ emitters, F17 and Cl33, in order to eliminate the half-life as the leading source of uncertainty in their ft values. Method: Half-lives of F17 and Cl33 were determined using β counting of implanted radioactive ion beam samples on a moving tape transport system at the Système de Production d'Ions Radioactifs Accélérés en Ligne low-energy identification station at the Grand Accélérateur National d'Ions Lourds. Results: The F17 half-life result, 64.347 (35) s, precise to ±0.05%, is a factor of 5 times more precise than the previous world average. The half-life of Cl33 was determined to be 2.5038 (22) s. The current precision of ±0.09% is nearly 2 times more precise compared to the previous world average. Conclusions: The precision achieved during the present measurements implies that the half-life no longer dominates the uncertainty of the ft values for both T=1/2 mirror decays F17 and Cl33.
id oai-inspirehep.net-1397106
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling oai-inspirehep.net-13971062022-08-10T13:06:28Zdoi:10.1103/PhysRevC.92.045503http://cds.cern.ch/record/2194350engGrinyer, JGrinyer, G FBabo, MBouzomita, HChauveau, PDelahaye, PDubois, MFrigot, RJardin, PLeboucher, CMaunoury, LSeiffert, CThomas, J CTraykov, EHigh-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33Nuclear Physics - ExperimentBackground: Measurements of the ft values for T=1/2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the ft values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T=1/2β+ emitters, F17 and Cl33, in order to eliminate the half-life as the leading source of uncertainty in their ft values. Method: Half-lives of F17 and Cl33 were determined using β counting of implanted radioactive ion beam samples on a moving tape transport system at the Système de Production d'Ions Radioactifs Accélérés en Ligne low-energy identification station at the Grand Accélérateur National d'Ions Lourds. Results: The F17 half-life result, 64.347 (35) s, precise to ±0.05%, is a factor of 5 times more precise than the previous world average. The half-life of Cl33 was determined to be 2.5038 (22) s. The current precision of ±0.09% is nearly 2 times more precise compared to the previous world average. Conclusions: The precision achieved during the present measurements implies that the half-life no longer dominates the uncertainty of the ft values for both T=1/2 mirror decays F17 and Cl33.oai:inspirehep.net:13971062015
spellingShingle Nuclear Physics - Experiment
Grinyer, J
Grinyer, G F
Babo, M
Bouzomita, H
Chauveau, P
Delahaye, P
Dubois, M
Frigot, R
Jardin, P
Leboucher, C
Maunoury, L
Seiffert, C
Thomas, J C
Traykov, E
High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33
title High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33
title_full High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33
title_fullStr High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33
title_full_unstemmed High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33
title_short High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33
title_sort high-precision half-life measurements of the t=1/2 mirror β decays f17 and cl33
topic Nuclear Physics - Experiment
url https://dx.doi.org/10.1103/PhysRevC.92.045503
http://cds.cern.ch/record/2194350
work_keys_str_mv AT grinyerj highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT grinyergf highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT babom highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT bouzomitah highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT chauveaup highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT delahayep highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT duboism highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT frigotr highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT jardinp highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT leboucherc highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT maunouryl highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT seiffertc highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT thomasjc highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33
AT traykove highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33