Cargando…
High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33
Background: Measurements of the ft values for T=1/2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the ft values are...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1103/PhysRevC.92.045503 http://cds.cern.ch/record/2194350 |
_version_ | 1780951052742295552 |
---|---|
author | Grinyer, J Grinyer, G F Babo, M Bouzomita, H Chauveau, P Delahaye, P Dubois, M Frigot, R Jardin, P Leboucher, C Maunoury, L Seiffert, C Thomas, J C Traykov, E |
author_facet | Grinyer, J Grinyer, G F Babo, M Bouzomita, H Chauveau, P Delahaye, P Dubois, M Frigot, R Jardin, P Leboucher, C Maunoury, L Seiffert, C Thomas, J C Traykov, E |
author_sort | Grinyer, J |
collection | CERN |
description | Background: Measurements of the ft values for T=1/2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the ft values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T=1/2β+ emitters, F17 and Cl33, in order to eliminate the half-life as the leading source of uncertainty in their ft values. Method: Half-lives of F17 and Cl33 were determined using β counting of implanted radioactive ion beam samples on a moving tape transport system at the Système de Production d'Ions Radioactifs Accélérés en Ligne low-energy identification station at the Grand Accélérateur National d'Ions Lourds. Results: The F17 half-life result, 64.347 (35) s, precise to ±0.05%, is a factor of 5 times more precise than the previous world average. The half-life of Cl33 was determined to be 2.5038 (22) s. The current precision of ±0.09% is nearly 2 times more precise compared to the previous world average. Conclusions: The precision achieved during the present measurements implies that the half-life no longer dominates the uncertainty of the ft values for both T=1/2 mirror decays F17 and Cl33. |
id | oai-inspirehep.net-1397106 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
record_format | invenio |
spelling | oai-inspirehep.net-13971062022-08-10T13:06:28Zdoi:10.1103/PhysRevC.92.045503http://cds.cern.ch/record/2194350engGrinyer, JGrinyer, G FBabo, MBouzomita, HChauveau, PDelahaye, PDubois, MFrigot, RJardin, PLeboucher, CMaunoury, LSeiffert, CThomas, J CTraykov, EHigh-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33Nuclear Physics - ExperimentBackground: Measurements of the ft values for T=1/2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the ft values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T=1/2β+ emitters, F17 and Cl33, in order to eliminate the half-life as the leading source of uncertainty in their ft values. Method: Half-lives of F17 and Cl33 were determined using β counting of implanted radioactive ion beam samples on a moving tape transport system at the Système de Production d'Ions Radioactifs Accélérés en Ligne low-energy identification station at the Grand Accélérateur National d'Ions Lourds. Results: The F17 half-life result, 64.347 (35) s, precise to ±0.05%, is a factor of 5 times more precise than the previous world average. The half-life of Cl33 was determined to be 2.5038 (22) s. The current precision of ±0.09% is nearly 2 times more precise compared to the previous world average. Conclusions: The precision achieved during the present measurements implies that the half-life no longer dominates the uncertainty of the ft values for both T=1/2 mirror decays F17 and Cl33.oai:inspirehep.net:13971062015 |
spellingShingle | Nuclear Physics - Experiment Grinyer, J Grinyer, G F Babo, M Bouzomita, H Chauveau, P Delahaye, P Dubois, M Frigot, R Jardin, P Leboucher, C Maunoury, L Seiffert, C Thomas, J C Traykov, E High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33 |
title | High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33 |
title_full | High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33 |
title_fullStr | High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33 |
title_full_unstemmed | High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33 |
title_short | High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33 |
title_sort | high-precision half-life measurements of the t=1/2 mirror β decays f17 and cl33 |
topic | Nuclear Physics - Experiment |
url | https://dx.doi.org/10.1103/PhysRevC.92.045503 http://cds.cern.ch/record/2194350 |
work_keys_str_mv | AT grinyerj highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT grinyergf highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT babom highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT bouzomitah highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT chauveaup highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT delahayep highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT duboism highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT frigotr highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT jardinp highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT leboucherc highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT maunouryl highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT seiffertc highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT thomasjc highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 AT traykove highprecisionhalflifemeasurementsofthet12mirrorbdecaysf17andcl33 |