Cargando…

Response of Polycrystalline Diamond Particle Detectors Measured with a High Intensity Electron Beam

Comprehensive understanding of beam losses in the LHC is required to ensure full machine protection and efficient operation. The existing BLM system using ionization chambers is not adequate to resolve losses with a time resolution below some 10 us. Ionization chambers are also not adequate to measu...

Descripción completa

Detalles Bibliográficos
Autores principales: Stein, Oliver, Burkart, Florian, Dehning, Bernd, Griesmayer, Erich, Schmidt, Ruediger, Sørensen, Christian, Wollmann, Daniel
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:http://cds.cern.ch/record/2141809
_version_ 1780950153509732352
author Stein, Oliver
Burkart, Florian
Dehning, Bernd
Griesmayer, Erich
Schmidt, Ruediger
Sørensen, Christian
Wollmann, Daniel
author_facet Stein, Oliver
Burkart, Florian
Dehning, Bernd
Griesmayer, Erich
Schmidt, Ruediger
Sørensen, Christian
Wollmann, Daniel
author_sort Stein, Oliver
collection CERN
description Comprehensive understanding of beam losses in the LHC is required to ensure full machine protection and efficient operation. The existing BLM system using ionization chambers is not adequate to resolve losses with a time resolution below some 10 us. Ionization chambers are also not adequate to measure very large transient losses, e.g. beam impacting on collimators. Diamond particle detectors with bunch-by-bunch resolution have therefore been used in LHC to measure fast particle losses with a time resolution down to a level of single bunches. Diamond detectors have also successfully been used for material damage studies in other facilities, e.g. HiRadMat at the CERN-SPS. To fully understand their potential, such detectors were characterized with an electron beam at the BTF in LNF INFN Italy, with bunch intensities from 10³ to 10⁹ electrons. The detector response and efficiency has been measured with a 50 Ω and a 1 Ω read-out system. This paper describes the experimental setup and the results of the experiment. In particular, the responses of three samples of 100 um single-crystalline diamond detectors and two samples of 500 um polycrystalline diamond detectors are presented.
id oai-inspirehep.net-1417478
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
record_format invenio
spelling oai-inspirehep.net-14174782022-08-10T12:59:22Zhttp://cds.cern.ch/record/2141809engStein, OliverBurkart, FlorianDehning, BerndGriesmayer, ErichSchmidt, RuedigerSørensen, ChristianWollmann, DanielResponse of Polycrystalline Diamond Particle Detectors Measured with a High Intensity Electron BeamAccelerators and Storage RingsComprehensive understanding of beam losses in the LHC is required to ensure full machine protection and efficient operation. The existing BLM system using ionization chambers is not adequate to resolve losses with a time resolution below some 10 us. Ionization chambers are also not adequate to measure very large transient losses, e.g. beam impacting on collimators. Diamond particle detectors with bunch-by-bunch resolution have therefore been used in LHC to measure fast particle losses with a time resolution down to a level of single bunches. Diamond detectors have also successfully been used for material damage studies in other facilities, e.g. HiRadMat at the CERN-SPS. To fully understand their potential, such detectors were characterized with an electron beam at the BTF in LNF INFN Italy, with bunch intensities from 10³ to 10⁹ electrons. The detector response and efficiency has been measured with a 50 Ω and a 1 Ω read-out system. This paper describes the experimental setup and the results of the experiment. In particular, the responses of three samples of 100 um single-crystalline diamond detectors and two samples of 500 um polycrystalline diamond detectors are presented.CERN-ACC-2015-305oai:inspirehep.net:14174782015
spellingShingle Accelerators and Storage Rings
Stein, Oliver
Burkart, Florian
Dehning, Bernd
Griesmayer, Erich
Schmidt, Ruediger
Sørensen, Christian
Wollmann, Daniel
Response of Polycrystalline Diamond Particle Detectors Measured with a High Intensity Electron Beam
title Response of Polycrystalline Diamond Particle Detectors Measured with a High Intensity Electron Beam
title_full Response of Polycrystalline Diamond Particle Detectors Measured with a High Intensity Electron Beam
title_fullStr Response of Polycrystalline Diamond Particle Detectors Measured with a High Intensity Electron Beam
title_full_unstemmed Response of Polycrystalline Diamond Particle Detectors Measured with a High Intensity Electron Beam
title_short Response of Polycrystalline Diamond Particle Detectors Measured with a High Intensity Electron Beam
title_sort response of polycrystalline diamond particle detectors measured with a high intensity electron beam
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/2141809
work_keys_str_mv AT steinoliver responseofpolycrystallinediamondparticledetectorsmeasuredwithahighintensityelectronbeam
AT burkartflorian responseofpolycrystallinediamondparticledetectorsmeasuredwithahighintensityelectronbeam
AT dehningbernd responseofpolycrystallinediamondparticledetectorsmeasuredwithahighintensityelectronbeam
AT griesmayererich responseofpolycrystallinediamondparticledetectorsmeasuredwithahighintensityelectronbeam
AT schmidtruediger responseofpolycrystallinediamondparticledetectorsmeasuredwithahighintensityelectronbeam
AT sørensenchristian responseofpolycrystallinediamondparticledetectorsmeasuredwithahighintensityelectronbeam
AT wollmanndaniel responseofpolycrystallinediamondparticledetectorsmeasuredwithahighintensityelectronbeam