Cargando…
The Beam Chopper Power Converter for MedAustron: Safety by Design and Development
MedAustron is the Austrian centre for hadron therapy and non-clinical research. The beam chopper system is an essential component for patient safety in specific hazardous situations as well as for beam delivery from the synchrotron to the irradiation rooms. This paper presents the results from the d...
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2015
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2141862 |
_version_ | 1780950164813381632 |
---|---|
author | Stadlbauer, Tobias Barnes, Michael Beerwald, Moritz Dirksen, Uwe Filippini, Roberto German, Xavier Kramer, Thomas Osmić, Fadmar Urschütz, Peter |
author_facet | Stadlbauer, Tobias Barnes, Michael Beerwald, Moritz Dirksen, Uwe Filippini, Roberto German, Xavier Kramer, Thomas Osmić, Fadmar Urschütz, Peter |
author_sort | Stadlbauer, Tobias |
collection | CERN |
description | MedAustron is the Austrian centre for hadron therapy and non-clinical research. The beam chopper system is an essential component for patient safety in specific hazardous situations as well as for beam delivery from the synchrotron to the irradiation rooms. This paper presents the results from the development phase and the commissioning of the MedAustron beam chopper system. Details will be given on the design, the risk management, the test and the verification of the chopper power converter (PKC). |
id | oai-inspirehep.net-1417928 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2015 |
record_format | invenio |
spelling | oai-inspirehep.net-14179282022-08-10T12:59:29Zhttp://cds.cern.ch/record/2141862engStadlbauer, TobiasBarnes, MichaelBeerwald, MoritzDirksen, UweFilippini, RobertoGerman, XavierKramer, ThomasOsmić, FadmarUrschütz, PeterThe Beam Chopper Power Converter for MedAustron: Safety by Design and DevelopmentAccelerators and Storage RingsMedAustron is the Austrian centre for hadron therapy and non-clinical research. The beam chopper system is an essential component for patient safety in specific hazardous situations as well as for beam delivery from the synchrotron to the irradiation rooms. This paper presents the results from the development phase and the commissioning of the MedAustron beam chopper system. Details will be given on the design, the risk management, the test and the verification of the chopper power converter (PKC).CERN-ACC-2015-253oai:inspirehep.net:14179282015 |
spellingShingle | Accelerators and Storage Rings Stadlbauer, Tobias Barnes, Michael Beerwald, Moritz Dirksen, Uwe Filippini, Roberto German, Xavier Kramer, Thomas Osmić, Fadmar Urschütz, Peter The Beam Chopper Power Converter for MedAustron: Safety by Design and Development |
title | The Beam Chopper Power Converter for MedAustron: Safety by Design and Development |
title_full | The Beam Chopper Power Converter for MedAustron: Safety by Design and Development |
title_fullStr | The Beam Chopper Power Converter for MedAustron: Safety by Design and Development |
title_full_unstemmed | The Beam Chopper Power Converter for MedAustron: Safety by Design and Development |
title_short | The Beam Chopper Power Converter for MedAustron: Safety by Design and Development |
title_sort | beam chopper power converter for medaustron: safety by design and development |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/2141862 |
work_keys_str_mv | AT stadlbauertobias thebeamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT barnesmichael thebeamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT beerwaldmoritz thebeamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT dirksenuwe thebeamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT filippiniroberto thebeamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT germanxavier thebeamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT kramerthomas thebeamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT osmicfadmar thebeamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT urschutzpeter thebeamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT stadlbauertobias beamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT barnesmichael beamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT beerwaldmoritz beamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT dirksenuwe beamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT filippiniroberto beamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT germanxavier beamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT kramerthomas beamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT osmicfadmar beamchopperpowerconverterformedaustronsafetybydesignanddevelopment AT urschutzpeter beamchopperpowerconverterformedaustronsafetybydesignanddevelopment |