Cargando…

Testing the behavior in hostile environment of Points of Load for LHC experiments

Devices used in future experiments at LHC will have to work in a very hostile environment. Power supply is a key aspect in this scenario and new converters must be designed in order to meet the future requirements. This is particularly true for Point of Load (PoL) converters that, being located as c...

Descripción completa

Detalles Bibliográficos
Autores principales: Lazzaroni, M, Citterio, M, Latorre, S, Lanza, A, Spiazzi, G
Lenguaje:eng
Publicado: ScienceDirect 2015
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.measurement.2015.07.023
http://cds.cern.ch/record/2711383
Descripción
Sumario:Devices used in future experiments at LHC will have to work in a very hostile environment. Power supply is a key aspect in this scenario and new converters must be designed in order to meet the future requirements. This is particularly true for Point of Load (PoL) converters that, being located as close as possible to the loads, must operate in a very harsh environment. This paper presents an experimental activity aimed to verify the compliance with a high stationary magnetic field of a commercial PoL, as well as experimental measurements aimed to test the performance of new GaN power devices used in PoL converters. In particular, a highly integrated commercial PoL converter, that includes in the same package the output filter inductor, is considered for the magnetic test, while an ad-hoc PoL converter, employing 40 V, 33 A normally off GaN MOSFETs has been designed and, finally, tested. Dynamic $R_{DSon}$ measurements of the same devices are also included.