Cargando…

Features measurement and reliability considerations on a proposed main converter for LHC experiments

Equipment working in hostile environment are the aim of this paper. Devices operating in the hostile environment such as found in future experiments at LHC will be called to work with a level of background radiation able to cause accumulation of a Total Ionizing Dose (TID) up to 10 kGy in Silicon, a...

Descripción completa

Detalles Bibliográficos
Autores principales: Lazzaroni, M, Citterio, M, Latorre, S, Lanza, A, Cova, P, Delmonte, N, Giuliani, F
Lenguaje:eng
Publicado: ScienceDirect 2015
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.measurement.2015.04.002
http://cds.cern.ch/record/2711385
_version_ 1780965286509281280
author Lazzaroni, M
Citterio, M
Latorre, S
Lanza, A
Cova, P
Delmonte, N
Giuliani, F
author_facet Lazzaroni, M
Citterio, M
Latorre, S
Lanza, A
Cova, P
Delmonte, N
Giuliani, F
author_sort Lazzaroni, M
collection CERN
description Equipment working in hostile environment are the aim of this paper. Devices operating in the hostile environment such as found in future experiments at LHC will be called to work with a level of background radiation able to cause accumulation of a Total Ionizing Dose (TID) up to 10 kGy in Silicon, and fluences up to 2 × 10$^{13}$ protons/cm$^{2}$ and 8 × 10$^{13}$ neutrons/cm$^{2}$ but also a high level of magnetic field. This new scenario will be taken into account and it will be very important in future when the High Luminosity (HL) LHC will be operative. It is so important, at this aim, to consider the fact that also the electronic converters devoted to generate the supply for the electronic circuits can be often called to operate in hostile environment. Thus, the power supply is a key aspects in this scenario and new converters need to be $ad-hoc$ re-designed in order to meet the future requirements that will be very stringent. In this paper a main DC–DC power converter, developed by authors in the framework of the APOLLO R&D; project, has been proposed. The experimental activity devoted to its electrical and thermal characterization, which can be defined as mandatory in order to obtain an evaluation of the features, is presented and deeply discussed. It is also important to characterize the system in order to evaluate the dependability features such as the RAMS (Reliability, Availability, Maintainability Safety) requirements. In particular, reliability is a very important aspect in experiments as ATLAS at CERN where maintenance should be scheduled only during the shutdown time. Also these aspects have been considered and discussed in the paper.
id oai-inspirehep.net-1423178
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2015
publisher ScienceDirect
record_format invenio
spelling oai-inspirehep.net-14231782020-02-26T12:48:09Zdoi:10.1016/j.measurement.2015.04.002http://cds.cern.ch/record/2711385engLazzaroni, MCitterio, MLatorre, SLanza, ACova, PDelmonte, NGiuliani, FFeatures measurement and reliability considerations on a proposed main converter for LHC experimentsParticle Physics - ExperimentEquipment working in hostile environment are the aim of this paper. Devices operating in the hostile environment such as found in future experiments at LHC will be called to work with a level of background radiation able to cause accumulation of a Total Ionizing Dose (TID) up to 10 kGy in Silicon, and fluences up to 2 × 10$^{13}$ protons/cm$^{2}$ and 8 × 10$^{13}$ neutrons/cm$^{2}$ but also a high level of magnetic field. This new scenario will be taken into account and it will be very important in future when the High Luminosity (HL) LHC will be operative. It is so important, at this aim, to consider the fact that also the electronic converters devoted to generate the supply for the electronic circuits can be often called to operate in hostile environment. Thus, the power supply is a key aspects in this scenario and new converters need to be $ad-hoc$ re-designed in order to meet the future requirements that will be very stringent. In this paper a main DC–DC power converter, developed by authors in the framework of the APOLLO R&D; project, has been proposed. The experimental activity devoted to its electrical and thermal characterization, which can be defined as mandatory in order to obtain an evaluation of the features, is presented and deeply discussed. It is also important to characterize the system in order to evaluate the dependability features such as the RAMS (Reliability, Availability, Maintainability Safety) requirements. In particular, reliability is a very important aspect in experiments as ATLAS at CERN where maintenance should be scheduled only during the shutdown time. Also these aspects have been considered and discussed in the paper.ScienceDirectoai:inspirehep.net:14231782015
spellingShingle Particle Physics - Experiment
Lazzaroni, M
Citterio, M
Latorre, S
Lanza, A
Cova, P
Delmonte, N
Giuliani, F
Features measurement and reliability considerations on a proposed main converter for LHC experiments
title Features measurement and reliability considerations on a proposed main converter for LHC experiments
title_full Features measurement and reliability considerations on a proposed main converter for LHC experiments
title_fullStr Features measurement and reliability considerations on a proposed main converter for LHC experiments
title_full_unstemmed Features measurement and reliability considerations on a proposed main converter for LHC experiments
title_short Features measurement and reliability considerations on a proposed main converter for LHC experiments
title_sort features measurement and reliability considerations on a proposed main converter for lhc experiments
topic Particle Physics - Experiment
url https://dx.doi.org/10.1016/j.measurement.2015.04.002
http://cds.cern.ch/record/2711385
work_keys_str_mv AT lazzaronim featuresmeasurementandreliabilityconsiderationsonaproposedmainconverterforlhcexperiments
AT citteriom featuresmeasurementandreliabilityconsiderationsonaproposedmainconverterforlhcexperiments
AT latorres featuresmeasurementandreliabilityconsiderationsonaproposedmainconverterforlhcexperiments
AT lanzaa featuresmeasurementandreliabilityconsiderationsonaproposedmainconverterforlhcexperiments
AT covap featuresmeasurementandreliabilityconsiderationsonaproposedmainconverterforlhcexperiments
AT delmonten featuresmeasurementandreliabilityconsiderationsonaproposedmainconverterforlhcexperiments
AT giulianif featuresmeasurementandreliabilityconsiderationsonaproposedmainconverterforlhcexperiments