Cargando…
The NA62 spectrometer acquisition system
The NA62 low mass spectrometer consists of 7000 straw tubes operating in vacuum. The front-end electronics is directly mounted on the detector and connected by a flexible PCB. The front-end board provides the amplification, shaping, discrimination and time measurements of the analogue signals from 1...
Autores principales: | Azorskiy, N, Ceccucci, A, Bendotti, J, Danielsson, H, Degrange, J, Dixon, N, Elsha, V, Enik, T, Glonti, L, Gusakov, Y, Kakurin, S, Kekelidze, V, Kislov, E, Kolesnikov, A, Koval, M, Lichard, P, Madigozhin, D, Morant, J, Movchan, S, Gomez, F Perez, Palladino, V, Polenkevich, I, Potrebenikov, Y, Ruggiero, G, Samsonov, V, Shkarovskiy, S, Sotnikov, A |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/11/02/C02064 http://cds.cern.ch/record/2252371 |
Ejemplares similares
-
A drift chamber with a new type of straws for operation in vacuum
por: Azorskiy, N, et al.
Publicado: (2016) -
New type of drift tubes for gas-discharge detectors operating in vacuum: Production technology and quality control
por: Azorskii, N I, et al.
Publicado: (2017) -
Longitudinal tension and mechanical stability of a pressurized straw tube
por: Glonti, L., et al.
Publicado: (2018) -
Determination of the anode wire position by visible light in a new type straw for NA62 experiment tracker
por: Glonti, L, et al.
Publicado: (2016) -
Design and test results of the first prototype detector based on thin-walled drift tubes for the NA62 experiment
por: Azorskiy, N I, et al.