Cargando…

Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures

The axial electric field of Alvarez drift tube linacs (DTLs) is known to be susceptible to variations due to static and dynamic effects like manufacturing tolerances and beam loading. Post-couplers are used to stabilize the accelerating fields of DTLs against tuning errors. Tilt sensitivity and its...

Descripción completa

Detalles Bibliográficos
Autores principales: Khalvati, Mohammad Reza, Ramberger, Suitbert
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.1103/PhysRevAccelBeams.19.042001
http://cds.cern.ch/record/2146109
_version_ 1780950356437499904
author Khalvati, Mohammad Reza
Ramberger, Suitbert
author_facet Khalvati, Mohammad Reza
Ramberger, Suitbert
author_sort Khalvati, Mohammad Reza
collection CERN
description The axial electric field of Alvarez drift tube linacs (DTLs) is known to be susceptible to variations due to static and dynamic effects like manufacturing tolerances and beam loading. Post-couplers are used to stabilize the accelerating fields of DTLs against tuning errors. Tilt sensitivity and its slope have been introduced as measures for the stability right from the invention of post-couplers but since then the actual stabilization has mostly been done by tedious iteration. In the present article, the local tilt-sensitivity slope TS 0 n is established as the principal measure for stabilization instead of tilt sensitivity or some visual slope, and its significance is developed on the basis of an equivalent-circuit diagram of the DTL. Experimental and 3D simulation results are used to analyze its behavior and to define a technique for stabilization that allows finding the best post-coupler settings with just four tilt-sensitivity measurements. CERN ’ s Linac4 DTL Tank 2 and Tank 3 have been stabilized successfully using this technique. The final tilt-sensitivity error has been reduced from 100% = MHz down to 3% = MHz for Tank 2 and down to 1% /MHz for Tank 3. Finally, an accurate procedure for tuning the structure using slug tuners is discussed.
id oai-inspirehep.net-1446927
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-14469272022-08-10T12:48:44Zdoi:10.1103/PhysRevAccelBeams.19.042001http://cds.cern.ch/record/2146109engKhalvati, Mohammad RezaRamberger, SuitbertStraightforward and accurate technique for post-coupler stabilization in drift tube linac structuresAccelerators and Storage RingsThe axial electric field of Alvarez drift tube linacs (DTLs) is known to be susceptible to variations due to static and dynamic effects like manufacturing tolerances and beam loading. Post-couplers are used to stabilize the accelerating fields of DTLs against tuning errors. Tilt sensitivity and its slope have been introduced as measures for the stability right from the invention of post-couplers but since then the actual stabilization has mostly been done by tedious iteration. In the present article, the local tilt-sensitivity slope TS 0 n is established as the principal measure for stabilization instead of tilt sensitivity or some visual slope, and its significance is developed on the basis of an equivalent-circuit diagram of the DTL. Experimental and 3D simulation results are used to analyze its behavior and to define a technique for stabilization that allows finding the best post-coupler settings with just four tilt-sensitivity measurements. CERN ’ s Linac4 DTL Tank 2 and Tank 3 have been stabilized successfully using this technique. The final tilt-sensitivity error has been reduced from 100% = MHz down to 3% = MHz for Tank 2 and down to 1% /MHz for Tank 3. Finally, an accurate procedure for tuning the structure using slug tuners is discussed.oai:inspirehep.net:14469272016
spellingShingle Accelerators and Storage Rings
Khalvati, Mohammad Reza
Ramberger, Suitbert
Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures
title Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures
title_full Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures
title_fullStr Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures
title_full_unstemmed Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures
title_short Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures
title_sort straightforward and accurate technique for post-coupler stabilization in drift tube linac structures
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1103/PhysRevAccelBeams.19.042001
http://cds.cern.ch/record/2146109
work_keys_str_mv AT khalvatimohammadreza straightforwardandaccuratetechniqueforpostcouplerstabilizationindrifttubelinacstructures
AT rambergersuitbert straightforwardandaccuratetechniqueforpostcouplerstabilizationindrifttubelinacstructures