Cargando…
Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures
The axial electric field of Alvarez drift tube linacs (DTLs) is known to be susceptible to variations due to static and dynamic effects like manufacturing tolerances and beam loading. Post-couplers are used to stabilize the accelerating fields of DTLs against tuning errors. Tilt sensitivity and its...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1103/PhysRevAccelBeams.19.042001 http://cds.cern.ch/record/2146109 |
_version_ | 1780950356437499904 |
---|---|
author | Khalvati, Mohammad Reza Ramberger, Suitbert |
author_facet | Khalvati, Mohammad Reza Ramberger, Suitbert |
author_sort | Khalvati, Mohammad Reza |
collection | CERN |
description | The axial electric field of Alvarez drift tube linacs (DTLs) is known to be susceptible to variations due to static and dynamic effects like manufacturing tolerances and beam loading. Post-couplers are used to stabilize the accelerating fields of DTLs against tuning errors. Tilt sensitivity and its slope have been introduced as measures for the stability right from the invention of post-couplers but since then the actual stabilization has mostly been done by tedious iteration. In the present article, the local tilt-sensitivity slope TS 0 n is established as the principal measure for stabilization instead of tilt sensitivity or some visual slope, and its significance is developed on the basis of an equivalent-circuit diagram of the DTL. Experimental and 3D simulation results are used to analyze its behavior and to define a technique for stabilization that allows finding the best post-coupler settings with just four tilt-sensitivity measurements. CERN ’ s Linac4 DTL Tank 2 and Tank 3 have been stabilized successfully using this technique. The final tilt-sensitivity error has been reduced from 100% = MHz down to 3% = MHz for Tank 2 and down to 1% /MHz for Tank 3. Finally, an accurate procedure for tuning the structure using slug tuners is discussed. |
id | oai-inspirehep.net-1446927 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | oai-inspirehep.net-14469272022-08-10T12:48:44Zdoi:10.1103/PhysRevAccelBeams.19.042001http://cds.cern.ch/record/2146109engKhalvati, Mohammad RezaRamberger, SuitbertStraightforward and accurate technique for post-coupler stabilization in drift tube linac structuresAccelerators and Storage RingsThe axial electric field of Alvarez drift tube linacs (DTLs) is known to be susceptible to variations due to static and dynamic effects like manufacturing tolerances and beam loading. Post-couplers are used to stabilize the accelerating fields of DTLs against tuning errors. Tilt sensitivity and its slope have been introduced as measures for the stability right from the invention of post-couplers but since then the actual stabilization has mostly been done by tedious iteration. In the present article, the local tilt-sensitivity slope TS 0 n is established as the principal measure for stabilization instead of tilt sensitivity or some visual slope, and its significance is developed on the basis of an equivalent-circuit diagram of the DTL. Experimental and 3D simulation results are used to analyze its behavior and to define a technique for stabilization that allows finding the best post-coupler settings with just four tilt-sensitivity measurements. CERN ’ s Linac4 DTL Tank 2 and Tank 3 have been stabilized successfully using this technique. The final tilt-sensitivity error has been reduced from 100% = MHz down to 3% = MHz for Tank 2 and down to 1% /MHz for Tank 3. Finally, an accurate procedure for tuning the structure using slug tuners is discussed.oai:inspirehep.net:14469272016 |
spellingShingle | Accelerators and Storage Rings Khalvati, Mohammad Reza Ramberger, Suitbert Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures |
title | Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures |
title_full | Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures |
title_fullStr | Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures |
title_full_unstemmed | Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures |
title_short | Straightforward and accurate technique for post-coupler stabilization in drift tube linac structures |
title_sort | straightforward and accurate technique for post-coupler stabilization in drift tube linac structures |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1103/PhysRevAccelBeams.19.042001 http://cds.cern.ch/record/2146109 |
work_keys_str_mv | AT khalvatimohammadreza straightforwardandaccuratetechniqueforpostcouplerstabilizationindrifttubelinacstructures AT rambergersuitbert straightforwardandaccuratetechniqueforpostcouplerstabilizationindrifttubelinacstructures |