Cargando…
Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam
The Fast Beam Conditions Monitor, BCM1F, in the Compact Muon Solenoid, CMS, experiment was operated since 2008 and delivered invaluable information on the machine induced background in the inner part of the CMS detector supporting a safe operation of the inner tracker and high quality data. Due to t...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2016.04.038 http://cds.cern.ch/record/2262876 |
_version_ | 1780954225213177856 |
---|---|
author | Hempel, M Afanaciev, K Burtowy, P Dabrowski, A Henschel, H Idzik, M Karacheban, O Lange, W Leonard, J Levy, I Lohmann, W Pollak, B Przyborowski, D Ryjov, V Schuwalow, S Stickland, D Walsh, R Zagozdzinska, A |
author_facet | Hempel, M Afanaciev, K Burtowy, P Dabrowski, A Henschel, H Idzik, M Karacheban, O Lange, W Leonard, J Levy, I Lohmann, W Pollak, B Przyborowski, D Ryjov, V Schuwalow, S Stickland, D Walsh, R Zagozdzinska, A |
author_sort | Hempel, M |
collection | CERN |
description | The Fast Beam Conditions Monitor, BCM1F, in the Compact Muon Solenoid, CMS, experiment was operated since 2008 and delivered invaluable information on the machine induced background in the inner part of the CMS detector supporting a safe operation of the inner tracker and high quality data. Due to the shortening of the time between two bunch crossings from 50 ns to 25 ns and higher expected luminosity at the Large Hadron Collider, LHC, in 2015, BCM1F needed an upgrade to higher bandwidth. In addition, BCM1F is used as an on-line luminometer operated independently of CMS. To match these requirements, the number of single crystal diamond sensors was enhanced from 8 to 24. Each sensor is subdivided into two pads, leading to 48 readout channels. Dedicated fast front-end ASICs were developed in 130 nm technology, and the back-end electronics is completely upgraded. An assembled prototype BCM1F detector comprising sensors, a fast front-end ASIC and optical analog readout was studied in a 5 GeV electron beam at the DESY-II accelerator. Results on the performance are given. |
id | oai-inspirehep.net-1455678 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | oai-inspirehep.net-14556782019-09-30T06:29:59Zdoi:10.1016/j.nima.2016.04.038http://cds.cern.ch/record/2262876engHempel, MAfanaciev, KBurtowy, PDabrowski, AHenschel, HIdzik, MKaracheban, OLange, WLeonard, JLevy, ILohmann, WPollak, BPrzyborowski, DRyjov, VSchuwalow, SStickland, DWalsh, RZagozdzinska, AMeasurements of the performance of a beam condition monitor prototype in a 5 GeV electron beamAccelerators and Storage RingsDetectors and Experimental TechniquesThe Fast Beam Conditions Monitor, BCM1F, in the Compact Muon Solenoid, CMS, experiment was operated since 2008 and delivered invaluable information on the machine induced background in the inner part of the CMS detector supporting a safe operation of the inner tracker and high quality data. Due to the shortening of the time between two bunch crossings from 50 ns to 25 ns and higher expected luminosity at the Large Hadron Collider, LHC, in 2015, BCM1F needed an upgrade to higher bandwidth. In addition, BCM1F is used as an on-line luminometer operated independently of CMS. To match these requirements, the number of single crystal diamond sensors was enhanced from 8 to 24. Each sensor is subdivided into two pads, leading to 48 readout channels. Dedicated fast front-end ASICs were developed in 130 nm technology, and the back-end electronics is completely upgraded. An assembled prototype BCM1F detector comprising sensors, a fast front-end ASIC and optical analog readout was studied in a 5 GeV electron beam at the DESY-II accelerator. Results on the performance are given.oai:inspirehep.net:14556782016 |
spellingShingle | Accelerators and Storage Rings Detectors and Experimental Techniques Hempel, M Afanaciev, K Burtowy, P Dabrowski, A Henschel, H Idzik, M Karacheban, O Lange, W Leonard, J Levy, I Lohmann, W Pollak, B Przyborowski, D Ryjov, V Schuwalow, S Stickland, D Walsh, R Zagozdzinska, A Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam |
title | Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam |
title_full | Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam |
title_fullStr | Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam |
title_full_unstemmed | Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam |
title_short | Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam |
title_sort | measurements of the performance of a beam condition monitor prototype in a 5 gev electron beam |
topic | Accelerators and Storage Rings Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2016.04.038 http://cds.cern.ch/record/2262876 |
work_keys_str_mv | AT hempelm measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT afanacievk measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT burtowyp measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT dabrowskia measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT henschelh measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT idzikm measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT karachebano measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT langew measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT leonardj measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT levyi measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT lohmannw measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT pollakb measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT przyborowskid measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT ryjovv measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT schuwalows measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT sticklandd measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT walshr measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam AT zagozdzinskaa measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam |