Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam

The Fast Beam Conditions Monitor, BCM1F, in the Compact Muon Solenoid, CMS, experiment was operated since 2008 and delivered invaluable information on the machine induced background in the inner part of the CMS detector supporting a safe operation of the inner tracker and high quality data. Due to t...

Descripción completa

Detalles Bibliográficos
Autores principales: Hempel, M, Afanaciev, K, Burtowy, P, Dabrowski, A, Henschel, H, Idzik, M, Karacheban, O, Lange, W, Leonard, J, Levy, I, Lohmann, W, Pollak, B, Przyborowski, D, Ryjov, V, Schuwalow, S, Stickland, D, Walsh, R, Zagozdzinska, A
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2016.04.038
http://cds.cern.ch/record/2262876
_version_ 1780954225213177856
author Hempel, M
Afanaciev, K
Burtowy, P
Dabrowski, A
Henschel, H
Idzik, M
Karacheban, O
Lange, W
Leonard, J
Levy, I
Lohmann, W
Pollak, B
Przyborowski, D
Ryjov, V
Schuwalow, S
Stickland, D
Walsh, R
Zagozdzinska, A
author_facet Hempel, M
Afanaciev, K
Burtowy, P
Dabrowski, A
Henschel, H
Idzik, M
Karacheban, O
Lange, W
Leonard, J
Levy, I
Lohmann, W
Pollak, B
Przyborowski, D
Ryjov, V
Schuwalow, S
Stickland, D
Walsh, R
Zagozdzinska, A
author_sort Hempel, M
collection CERN
description The Fast Beam Conditions Monitor, BCM1F, in the Compact Muon Solenoid, CMS, experiment was operated since 2008 and delivered invaluable information on the machine induced background in the inner part of the CMS detector supporting a safe operation of the inner tracker and high quality data. Due to the shortening of the time between two bunch crossings from 50 ns to 25 ns and higher expected luminosity at the Large Hadron Collider, LHC, in 2015, BCM1F needed an upgrade to higher bandwidth. In addition, BCM1F is used as an on-line luminometer operated independently of CMS. To match these requirements, the number of single crystal diamond sensors was enhanced from 8 to 24. Each sensor is subdivided into two pads, leading to 48 readout channels. Dedicated fast front-end ASICs were developed in 130 nm technology, and the back-end electronics is completely upgraded. An assembled prototype BCM1F detector comprising sensors, a fast front-end ASIC and optical analog readout was studied in a 5 GeV electron beam at the DESY-II accelerator. Results on the performance are given.
id oai-inspirehep.net-1455678
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-14556782019-09-30T06:29:59Zdoi:10.1016/j.nima.2016.04.038http://cds.cern.ch/record/2262876engHempel, MAfanaciev, KBurtowy, PDabrowski, AHenschel, HIdzik, MKaracheban, OLange, WLeonard, JLevy, ILohmann, WPollak, BPrzyborowski, DRyjov, VSchuwalow, SStickland, DWalsh, RZagozdzinska, AMeasurements of the performance of a beam condition monitor prototype in a 5 GeV electron beamAccelerators and Storage RingsDetectors and Experimental TechniquesThe Fast Beam Conditions Monitor, BCM1F, in the Compact Muon Solenoid, CMS, experiment was operated since 2008 and delivered invaluable information on the machine induced background in the inner part of the CMS detector supporting a safe operation of the inner tracker and high quality data. Due to the shortening of the time between two bunch crossings from 50 ns to 25 ns and higher expected luminosity at the Large Hadron Collider, LHC, in 2015, BCM1F needed an upgrade to higher bandwidth. In addition, BCM1F is used as an on-line luminometer operated independently of CMS. To match these requirements, the number of single crystal diamond sensors was enhanced from 8 to 24. Each sensor is subdivided into two pads, leading to 48 readout channels. Dedicated fast front-end ASICs were developed in 130 nm technology, and the back-end electronics is completely upgraded. An assembled prototype BCM1F detector comprising sensors, a fast front-end ASIC and optical analog readout was studied in a 5 GeV electron beam at the DESY-II accelerator. Results on the performance are given.oai:inspirehep.net:14556782016
spellingShingle Accelerators and Storage Rings
Detectors and Experimental Techniques
Hempel, M
Afanaciev, K
Burtowy, P
Dabrowski, A
Henschel, H
Idzik, M
Karacheban, O
Lange, W
Leonard, J
Levy, I
Lohmann, W
Pollak, B
Przyborowski, D
Ryjov, V
Schuwalow, S
Stickland, D
Walsh, R
Zagozdzinska, A
Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam
title Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam
title_full Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam
title_fullStr Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam
title_full_unstemmed Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam
title_short Measurements of the performance of a beam condition monitor prototype in a 5 GeV electron beam
title_sort measurements of the performance of a beam condition monitor prototype in a 5 gev electron beam
topic Accelerators and Storage Rings
Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2016.04.038
http://cds.cern.ch/record/2262876
work_keys_str_mv AT hempelm measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT afanacievk measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT burtowyp measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT dabrowskia measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT henschelh measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT idzikm measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT karachebano measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT langew measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT leonardj measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT levyi measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT lohmannw measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT pollakb measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT przyborowskid measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT ryjovv measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT schuwalows measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT sticklandd measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT walshr measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam
AT zagozdzinskaa measurementsoftheperformanceofabeamconditionmonitorprototypeina5gevelectronbeam