Cargando…

Self-triggering readout system for the neutron lifetime experiment PENeLOPE

The aim of PENeLOPE (Precision Experiment on Neutron Lifetime Operating with Proton Extraction) at the Forschungsreaktor München II is a high-precision measurement of the neutron lifetime and thereby an improvement of the parameter׳s precision by one order of magnitude. In order to achieve a higher...

Descripción completa

Detalles Bibliográficos
Autores principales: Gaisbauer, D, Konorov, I, Steffen, D, Paul, S
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2015.10.049
http://cds.cern.ch/record/2263094
_version_ 1780954226512363520
author Gaisbauer, D
Konorov, I
Steffen, D
Paul, S
author_facet Gaisbauer, D
Konorov, I
Steffen, D
Paul, S
author_sort Gaisbauer, D
collection CERN
description The aim of PENeLOPE (Precision Experiment on Neutron Lifetime Operating with Proton Extraction) at the Forschungsreaktor München II is a high-precision measurement of the neutron lifetime and thereby an improvement of the parameter׳s precision by one order of magnitude. In order to achieve a higher accuracy, modern experiments naturally require state-of-the-art readout electronics, as well as high-performance data acquisition systems. This paper presents the self-triggering readout system designed for PENeLOPE which features a continuous pedestal tracking, configurable signal detection logic, floating ground up to 30 kV, cryogenic environment and the novel Switched Enabling Protocol (SEP). The SEP is a time-division multiplexing transport level protocol developed for a star network topology.
id oai-inspirehep.net-1457965
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-14579652019-09-30T06:29:59Zdoi:10.1016/j.nima.2015.10.049http://cds.cern.ch/record/2263094engGaisbauer, DKonorov, ISteffen, DPaul, SSelf-triggering readout system for the neutron lifetime experiment PENeLOPEDetectors and Experimental TechniquesThe aim of PENeLOPE (Precision Experiment on Neutron Lifetime Operating with Proton Extraction) at the Forschungsreaktor München II is a high-precision measurement of the neutron lifetime and thereby an improvement of the parameter׳s precision by one order of magnitude. In order to achieve a higher accuracy, modern experiments naturally require state-of-the-art readout electronics, as well as high-performance data acquisition systems. This paper presents the self-triggering readout system designed for PENeLOPE which features a continuous pedestal tracking, configurable signal detection logic, floating ground up to 30 kV, cryogenic environment and the novel Switched Enabling Protocol (SEP). The SEP is a time-division multiplexing transport level protocol developed for a star network topology.oai:inspirehep.net:14579652016
spellingShingle Detectors and Experimental Techniques
Gaisbauer, D
Konorov, I
Steffen, D
Paul, S
Self-triggering readout system for the neutron lifetime experiment PENeLOPE
title Self-triggering readout system for the neutron lifetime experiment PENeLOPE
title_full Self-triggering readout system for the neutron lifetime experiment PENeLOPE
title_fullStr Self-triggering readout system for the neutron lifetime experiment PENeLOPE
title_full_unstemmed Self-triggering readout system for the neutron lifetime experiment PENeLOPE
title_short Self-triggering readout system for the neutron lifetime experiment PENeLOPE
title_sort self-triggering readout system for the neutron lifetime experiment penelope
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2015.10.049
http://cds.cern.ch/record/2263094
work_keys_str_mv AT gaisbauerd selftriggeringreadoutsystemfortheneutronlifetimeexperimentpenelope
AT konorovi selftriggeringreadoutsystemfortheneutronlifetimeexperimentpenelope
AT steffend selftriggeringreadoutsystemfortheneutronlifetimeexperimentpenelope
AT pauls selftriggeringreadoutsystemfortheneutronlifetimeexperimentpenelope