Geant4 Simulations for the Analysis of (n, $\gamma $ ) Measurements at n_TOF

At the n_TOF facility at CERN, the (n, $\gamma $ ) experiments are usually carriedout with a set of C$_{6}$ D$_{6}$ scintillators, a simple setup characterized by a low neutron sensitivity. The drawback of this simple detection setup is an elaborated analysis procedure, the so called Pulse Height We...

Descripción completa

Detalles Bibliográficos
Autores principales: Lerendegui-Marco, J, Guerrero, C, Cortés-Giraldo, M A, Quesada, J M
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.1007/978-3-319-21191-6_17
http://cds.cern.ch/record/2265739
_version_ 1780954501700648960
author Lerendegui-Marco, J
Guerrero, C
Cortés-Giraldo, M A
Quesada, J M
author_facet Lerendegui-Marco, J
Guerrero, C
Cortés-Giraldo, M A
Quesada, J M
author_sort Lerendegui-Marco, J
collection CERN
description At the n_TOF facility at CERN, the (n, $\gamma $ ) experiments are usually carriedout with a set of C$_{6}$ D$_{6}$ scintillators, a simple setup characterized by a low neutron sensitivity. The drawback of this simple detection setup is an elaborated analysis procedure, the so called Pulse Height Weighting Technique, that requires a manipulation of the experimental detector response. The modeling of the detector response can just be done with help of Monte Carlo (MC) simulations. The goal of this work is to provide an overview of the analysis technique focusing on the detailed simulations performed with the Geant4 toolkit.
id oai-inspirehep.net-1462864
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-14628642019-09-30T06:29:59Zdoi:10.1007/978-3-319-21191-6_17http://cds.cern.ch/record/2265739engLerendegui-Marco, JGuerrero, CCortés-Giraldo, M AQuesada, J MGeant4 Simulations for the Analysis of (n, $\gamma $ ) Measurements at n_TOFNuclear Physics - TheoryAt the n_TOF facility at CERN, the (n, $\gamma $ ) experiments are usually carriedout with a set of C$_{6}$ D$_{6}$ scintillators, a simple setup characterized by a low neutron sensitivity. The drawback of this simple detection setup is an elaborated analysis procedure, the so called Pulse Height Weighting Technique, that requires a manipulation of the experimental detector response. The modeling of the detector response can just be done with help of Monte Carlo (MC) simulations. The goal of this work is to provide an overview of the analysis technique focusing on the detailed simulations performed with the Geant4 toolkit.oai:inspirehep.net:14628642016
spellingShingle Nuclear Physics - Theory
Lerendegui-Marco, J
Guerrero, C
Cortés-Giraldo, M A
Quesada, J M
Geant4 Simulations for the Analysis of (n, $\gamma $ ) Measurements at n_TOF
title Geant4 Simulations for the Analysis of (n, $\gamma $ ) Measurements at n_TOF
title_full Geant4 Simulations for the Analysis of (n, $\gamma $ ) Measurements at n_TOF
title_fullStr Geant4 Simulations for the Analysis of (n, $\gamma $ ) Measurements at n_TOF
title_full_unstemmed Geant4 Simulations for the Analysis of (n, $\gamma $ ) Measurements at n_TOF
title_short Geant4 Simulations for the Analysis of (n, $\gamma $ ) Measurements at n_TOF
title_sort geant4 simulations for the analysis of (n, $\gamma $ ) measurements at n_tof
topic Nuclear Physics - Theory
url https://dx.doi.org/10.1007/978-3-319-21191-6_17
http://cds.cern.ch/record/2265739
work_keys_str_mv AT lerendeguimarcoj geant4simulationsfortheanalysisofngammameasurementsatntof
AT guerreroc geant4simulationsfortheanalysisofngammameasurementsatntof
AT cortesgiraldoma geant4simulationsfortheanalysisofngammameasurementsatntof
AT quesadajm geant4simulationsfortheanalysisofngammameasurementsatntof