Readout scheme for the Baby-MIND detector
A readout scheme has been designed for the plastic scintillator bars of the Baby-MIND detector modules. This spectrometer will measure momentum and identify the charge of 1 GeV/c muons with magnetized iron plates interleaved with detector modules. One challenge the detector aims to address is that o...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
SISSA
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.22323/1.252.0031 http://cds.cern.ch/record/2266598 |
_version_ | 1780954617900695552 |
---|---|
author | Noah, Etam Blondel, A Cadoux, F Favre, Y Martinez, B Nicola, L Parsa, S Rayner, M Antonova, M Fedotov, S Izmaylov, A Kleymenova, A Khabibullin, M Khotyantsev, A Kudenko, Y Likhacheva, V Mefodiev, A Mineev, O Ovsiannikova, T Shaykhiev, A Suvorov, S Yershov, N Tsenov, R |
author_facet | Noah, Etam Blondel, A Cadoux, F Favre, Y Martinez, B Nicola, L Parsa, S Rayner, M Antonova, M Fedotov, S Izmaylov, A Kleymenova, A Khabibullin, M Khotyantsev, A Kudenko, Y Likhacheva, V Mefodiev, A Mineev, O Ovsiannikova, T Shaykhiev, A Suvorov, S Yershov, N Tsenov, R |
author_sort | Noah, Etam |
collection | CERN |
description | A readout scheme has been designed for the plastic scintillator bars of the Baby-MIND detector modules. This spectrometer will measure momentum and identify the charge of 1 GeV/c muons with magnetized iron plates interleaved with detector modules. One challenge the detector aims to address is that of keeping high charge identification efficiencies for momenta below 1 GeV/c where multiple scattering in the iron plates degrades momentum resolution. A front-end board has been developed, with 3 CITIROC readout chips per board and up to 96 channels. Hamamatsu MPPCs type S12571-025C photosensors were chosen for readout of wavelength shifting fibers embedded in plastic scintillators. Procurement of the MPPCs has been carried out to instrument 3000 channels in total. Design choices and first results of this readout scheme are presented. |
id | oai-inspirehep.net-1468316 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
publisher | SISSA |
record_format | invenio |
spelling | oai-inspirehep.net-14683162019-10-15T15:26:54Zdoi:10.22323/1.252.0031http://cds.cern.ch/record/2266598engNoah, EtamBlondel, ACadoux, FFavre, YMartinez, BNicola, LParsa, SRayner, MAntonova, MFedotov, SIzmaylov, AKleymenova, AKhabibullin, MKhotyantsev, AKudenko, YLikhacheva, VMefodiev, AMineev, OOvsiannikova, TShaykhiev, ASuvorov, SYershov, NTsenov, RReadout scheme for the Baby-MIND detectorDetectors and Experimental TechniquesA readout scheme has been designed for the plastic scintillator bars of the Baby-MIND detector modules. This spectrometer will measure momentum and identify the charge of 1 GeV/c muons with magnetized iron plates interleaved with detector modules. One challenge the detector aims to address is that of keeping high charge identification efficiencies for momenta below 1 GeV/c where multiple scattering in the iron plates degrades momentum resolution. A front-end board has been developed, with 3 CITIROC readout chips per board and up to 96 channels. Hamamatsu MPPCs type S12571-025C photosensors were chosen for readout of wavelength shifting fibers embedded in plastic scintillators. Procurement of the MPPCs has been carried out to instrument 3000 channels in total. Design choices and first results of this readout scheme are presented.SISSAoai:inspirehep.net:14683162016 |
spellingShingle | Detectors and Experimental Techniques Noah, Etam Blondel, A Cadoux, F Favre, Y Martinez, B Nicola, L Parsa, S Rayner, M Antonova, M Fedotov, S Izmaylov, A Kleymenova, A Khabibullin, M Khotyantsev, A Kudenko, Y Likhacheva, V Mefodiev, A Mineev, O Ovsiannikova, T Shaykhiev, A Suvorov, S Yershov, N Tsenov, R Readout scheme for the Baby-MIND detector |
title | Readout scheme for the Baby-MIND detector |
title_full | Readout scheme for the Baby-MIND detector |
title_fullStr | Readout scheme for the Baby-MIND detector |
title_full_unstemmed | Readout scheme for the Baby-MIND detector |
title_short | Readout scheme for the Baby-MIND detector |
title_sort | readout scheme for the baby-mind detector |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.22323/1.252.0031 http://cds.cern.ch/record/2266598 |
work_keys_str_mv | AT noahetam readoutschemeforthebabyminddetector AT blondela readoutschemeforthebabyminddetector AT cadouxf readoutschemeforthebabyminddetector AT favrey readoutschemeforthebabyminddetector AT martinezb readoutschemeforthebabyminddetector AT nicolal readoutschemeforthebabyminddetector AT parsas readoutschemeforthebabyminddetector AT raynerm readoutschemeforthebabyminddetector AT antonovam readoutschemeforthebabyminddetector AT fedotovs readoutschemeforthebabyminddetector AT izmaylova readoutschemeforthebabyminddetector AT kleymenovaa readoutschemeforthebabyminddetector AT khabibullinm readoutschemeforthebabyminddetector AT khotyantseva readoutschemeforthebabyminddetector AT kudenkoy readoutschemeforthebabyminddetector AT likhachevav readoutschemeforthebabyminddetector AT mefodieva readoutschemeforthebabyminddetector AT mineevo readoutschemeforthebabyminddetector AT ovsiannikovat readoutschemeforthebabyminddetector AT shaykhieva readoutschemeforthebabyminddetector AT suvorovs readoutschemeforthebabyminddetector AT yershovn readoutschemeforthebabyminddetector AT tsenovr readoutschemeforthebabyminddetector |