Cargando…

Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC

During the LHC long shut down in 2014, the transverse beam size diagnostics based on synchrotron radiation was upgraded in order to cope with the increase of the LHC beam energy to 6.5 TeV. The wavelength used for imaging was shifted to near ultra-violet to reduce the contribution of diffraction to...

Descripción completa

Detalles Bibliográficos
Autores principales: Trad, Georges, Bravin, Enrico, Goldblatt, Aurélie, Mazzoni, Stefano, Mitsuhashi, Toshiyuki, Roncarolo, Federico
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-IPAC2016-MOPMR030
http://cds.cern.ch/record/2207347
_version_ 1780951680182910976
author Trad, Georges
Bravin, Enrico
Goldblatt, Aurélie
Mazzoni, Stefano
Mitsuhashi, Toshiyuki
Roncarolo, Federico
author_facet Trad, Georges
Bravin, Enrico
Goldblatt, Aurélie
Mazzoni, Stefano
Mitsuhashi, Toshiyuki
Roncarolo, Federico
author_sort Trad, Georges
collection CERN
description During the LHC long shut down in 2014, the transverse beam size diagnostics based on synchrotron radiation was upgraded in order to cope with the increase of the LHC beam energy to 6.5 TeV. The wavelength used for imaging was shifted to near ultra-violet to reduce the contribution of diffraction to the system resolution, while in parallel, a new diagnostic system based on double slit interferometry was installed to measure the beam size by studying the spatial coherence of the emitted synchrotron radiation. This method has never been implemented before in a proton machine. A Hartmann mask was also installed to identify possible wavefront distortions that could affect the system accuracy. This paper will focus on the comparison of visible and the near ultra-violet imaging and on the first experience with interferometry.
id oai-inspirehep.net-1469863
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-14698632022-08-10T12:47:50Zdoi:10.18429/JACoW-IPAC2016-MOPMR030http://cds.cern.ch/record/2207347engTrad, GeorgesBravin, EnricoGoldblatt, AurélieMazzoni, StefanoMitsuhashi, ToshiyukiRoncarolo, FedericoPerformance of the Upgraded Synchrotron Radiation Diagnostics at the LHCAccelerators and Storage RingsDuring the LHC long shut down in 2014, the transverse beam size diagnostics based on synchrotron radiation was upgraded in order to cope with the increase of the LHC beam energy to 6.5 TeV. The wavelength used for imaging was shifted to near ultra-violet to reduce the contribution of diffraction to the system resolution, while in parallel, a new diagnostic system based on double slit interferometry was installed to measure the beam size by studying the spatial coherence of the emitted synchrotron radiation. This method has never been implemented before in a proton machine. A Hartmann mask was also installed to identify possible wavefront distortions that could affect the system accuracy. This paper will focus on the comparison of visible and the near ultra-violet imaging and on the first experience with interferometry.CERN-ACC-2016-278oai:inspirehep.net:14698632016
spellingShingle Accelerators and Storage Rings
Trad, Georges
Bravin, Enrico
Goldblatt, Aurélie
Mazzoni, Stefano
Mitsuhashi, Toshiyuki
Roncarolo, Federico
Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC
title Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC
title_full Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC
title_fullStr Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC
title_full_unstemmed Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC
title_short Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC
title_sort performance of the upgraded synchrotron radiation diagnostics at the lhc
topic Accelerators and Storage Rings
url https://dx.doi.org/10.18429/JACoW-IPAC2016-MOPMR030
http://cds.cern.ch/record/2207347
work_keys_str_mv AT tradgeorges performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc
AT bravinenrico performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc
AT goldblattaurelie performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc
AT mazzonistefano performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc
AT mitsuhashitoshiyuki performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc
AT roncarolofederico performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc