Cargando…
Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC
During the LHC long shut down in 2014, the transverse beam size diagnostics based on synchrotron radiation was upgraded in order to cope with the increase of the LHC beam energy to 6.5 TeV. The wavelength used for imaging was shifted to near ultra-violet to reduce the contribution of diffraction to...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2016-MOPMR030 http://cds.cern.ch/record/2207347 |
_version_ | 1780951680182910976 |
---|---|
author | Trad, Georges Bravin, Enrico Goldblatt, Aurélie Mazzoni, Stefano Mitsuhashi, Toshiyuki Roncarolo, Federico |
author_facet | Trad, Georges Bravin, Enrico Goldblatt, Aurélie Mazzoni, Stefano Mitsuhashi, Toshiyuki Roncarolo, Federico |
author_sort | Trad, Georges |
collection | CERN |
description | During the LHC long shut down in 2014, the transverse beam size diagnostics based on synchrotron radiation was upgraded in order to cope with the increase of the LHC beam energy to 6.5 TeV. The wavelength used for imaging was shifted to near ultra-violet to reduce the contribution of diffraction to the system resolution, while in parallel, a new diagnostic system based on double slit interferometry was installed to measure the beam size by studying the spatial coherence of the emitted synchrotron radiation. This method has never been implemented before in a proton machine. A Hartmann mask was also installed to identify possible wavefront distortions that could affect the system accuracy. This paper will focus on the comparison of visible and the near ultra-violet imaging and on the first experience with interferometry. |
id | oai-inspirehep.net-1469863 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | oai-inspirehep.net-14698632022-08-10T12:47:50Zdoi:10.18429/JACoW-IPAC2016-MOPMR030http://cds.cern.ch/record/2207347engTrad, GeorgesBravin, EnricoGoldblatt, AurélieMazzoni, StefanoMitsuhashi, ToshiyukiRoncarolo, FedericoPerformance of the Upgraded Synchrotron Radiation Diagnostics at the LHCAccelerators and Storage RingsDuring the LHC long shut down in 2014, the transverse beam size diagnostics based on synchrotron radiation was upgraded in order to cope with the increase of the LHC beam energy to 6.5 TeV. The wavelength used for imaging was shifted to near ultra-violet to reduce the contribution of diffraction to the system resolution, while in parallel, a new diagnostic system based on double slit interferometry was installed to measure the beam size by studying the spatial coherence of the emitted synchrotron radiation. This method has never been implemented before in a proton machine. A Hartmann mask was also installed to identify possible wavefront distortions that could affect the system accuracy. This paper will focus on the comparison of visible and the near ultra-violet imaging and on the first experience with interferometry.CERN-ACC-2016-278oai:inspirehep.net:14698632016 |
spellingShingle | Accelerators and Storage Rings Trad, Georges Bravin, Enrico Goldblatt, Aurélie Mazzoni, Stefano Mitsuhashi, Toshiyuki Roncarolo, Federico Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC |
title | Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC |
title_full | Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC |
title_fullStr | Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC |
title_full_unstemmed | Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC |
title_short | Performance of the Upgraded Synchrotron Radiation Diagnostics at the LHC |
title_sort | performance of the upgraded synchrotron radiation diagnostics at the lhc |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.18429/JACoW-IPAC2016-MOPMR030 http://cds.cern.ch/record/2207347 |
work_keys_str_mv | AT tradgeorges performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc AT bravinenrico performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc AT goldblattaurelie performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc AT mazzonistefano performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc AT mitsuhashitoshiyuki performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc AT roncarolofederico performanceoftheupgradedsynchrotronradiationdiagnosticsatthelhc |