Cargando…

Beam Energy Deposition from PS Booster and Production Rates of Selected Medical Radioisotopes in the CERN-MEDICIS Target

CERN-MEDICIS uses the scattered (ca. 90%) 1.4 GeV, 2 uA protons delivered by the PS Booster to the ISOLDE target, which would normally end up in the beam dump. After irradiation, the MEDICIS target is transported back to an offline isotope mass separator, where the produced isotopes are mass separat...

Descripción completa

Detalles Bibliográficos
Autores principales: Gonsalves, Basil, Barlow, Roger, Dos Santos Augusto, Ricardo Manuel, Lee, Sangcheol, Stora, Thierry
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-IPAC2016-TUPOY017
http://cds.cern.ch/record/2207394
_version_ 1780951691134238720
author Gonsalves, Basil
Barlow, Roger
Dos Santos Augusto, Ricardo Manuel
Lee, Sangcheol
Stora, Thierry
author_facet Gonsalves, Basil
Barlow, Roger
Dos Santos Augusto, Ricardo Manuel
Lee, Sangcheol
Stora, Thierry
author_sort Gonsalves, Basil
collection CERN
description CERN-MEDICIS uses the scattered (ca. 90%) 1.4 GeV, 2 uA protons delivered by the PS Booster to the ISOLDE target, which would normally end up in the beam dump. After irradiation, the MEDICIS target is transported back to an offline isotope mass separator, where the produced isotopes are mass separated, and are then collected. The required medical radioisotopes are later chemically separated in the class A laboratory. The radioisotopes are transported to partner hospitals for processing and preparation for medical use, imaging or therapy. Production of the isotopes is affected by the designs of the ISOLDE and MEDICIS targets. The MEDICIS target unit is a configurable unit, allowing for variations in target material as well as ion source for the production of selected medical radioisotopes. The energy deposition on both targets is simulated using the Monte Carlo code FLUKA, along with the in-beam production of some medical isotopes of interest. Diffusion and effusion efficiencies are then applied to estimate their production.
id oai-inspirehep.net-1470074
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-14700742022-08-10T12:48:01Zdoi:10.18429/JACoW-IPAC2016-TUPOY017http://cds.cern.ch/record/2207394engGonsalves, BasilBarlow, RogerDos Santos Augusto, Ricardo ManuelLee, SangcheolStora, ThierryBeam Energy Deposition from PS Booster and Production Rates of Selected Medical Radioisotopes in the CERN-MEDICIS TargetAccelerators and Storage RingsCERN-MEDICIS uses the scattered (ca. 90%) 1.4 GeV, 2 uA protons delivered by the PS Booster to the ISOLDE target, which would normally end up in the beam dump. After irradiation, the MEDICIS target is transported back to an offline isotope mass separator, where the produced isotopes are mass separated, and are then collected. The required medical radioisotopes are later chemically separated in the class A laboratory. The radioisotopes are transported to partner hospitals for processing and preparation for medical use, imaging or therapy. Production of the isotopes is affected by the designs of the ISOLDE and MEDICIS targets. The MEDICIS target unit is a configurable unit, allowing for variations in target material as well as ion source for the production of selected medical radioisotopes. The energy deposition on both targets is simulated using the Monte Carlo code FLUKA, along with the in-beam production of some medical isotopes of interest. Diffusion and effusion efficiencies are then applied to estimate their production.CERN-ACC-2016-231oai:inspirehep.net:14700742016
spellingShingle Accelerators and Storage Rings
Gonsalves, Basil
Barlow, Roger
Dos Santos Augusto, Ricardo Manuel
Lee, Sangcheol
Stora, Thierry
Beam Energy Deposition from PS Booster and Production Rates of Selected Medical Radioisotopes in the CERN-MEDICIS Target
title Beam Energy Deposition from PS Booster and Production Rates of Selected Medical Radioisotopes in the CERN-MEDICIS Target
title_full Beam Energy Deposition from PS Booster and Production Rates of Selected Medical Radioisotopes in the CERN-MEDICIS Target
title_fullStr Beam Energy Deposition from PS Booster and Production Rates of Selected Medical Radioisotopes in the CERN-MEDICIS Target
title_full_unstemmed Beam Energy Deposition from PS Booster and Production Rates of Selected Medical Radioisotopes in the CERN-MEDICIS Target
title_short Beam Energy Deposition from PS Booster and Production Rates of Selected Medical Radioisotopes in the CERN-MEDICIS Target
title_sort beam energy deposition from ps booster and production rates of selected medical radioisotopes in the cern-medicis target
topic Accelerators and Storage Rings
url https://dx.doi.org/10.18429/JACoW-IPAC2016-TUPOY017
http://cds.cern.ch/record/2207394
work_keys_str_mv AT gonsalvesbasil beamenergydepositionfrompsboosterandproductionratesofselectedmedicalradioisotopesinthecernmedicistarget
AT barlowroger beamenergydepositionfrompsboosterandproductionratesofselectedmedicalradioisotopesinthecernmedicistarget
AT dossantosaugustoricardomanuel beamenergydepositionfrompsboosterandproductionratesofselectedmedicalradioisotopesinthecernmedicistarget
AT leesangcheol beamenergydepositionfrompsboosterandproductionratesofselectedmedicalradioisotopesinthecernmedicistarget
AT storathierry beamenergydepositionfrompsboosterandproductionratesofselectedmedicalradioisotopesinthecernmedicistarget