Cargando…
Optics-measurement-based BPM Calibration
The LHC beta functions (β) can be measured using the phase or the amplitude of betatron oscillations obtained with beam position monitors (BPMs). Using the amplitude information results in a β measurement affected by BPM calibration. This work aims at calibrating BPMs using optics measurements. For...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2016-THPMB041 http://cds.cern.ch/record/2207435 |
_version_ | 1780951700784283648 |
---|---|
author | Garcia-Tabares, Ana Carlier, Felix Coello de Portugal, Jaime Maria Langner, Andy Maclean, Ewen Malina, Lukas Persson, Tobias Skowroński, Piotr Solfaroli Camillocci, Matteo Tomás, Rogelio |
author_facet | Garcia-Tabares, Ana Carlier, Felix Coello de Portugal, Jaime Maria Langner, Andy Maclean, Ewen Malina, Lukas Persson, Tobias Skowroński, Piotr Solfaroli Camillocci, Matteo Tomás, Rogelio |
author_sort | Garcia-Tabares, Ana |
collection | CERN |
description | The LHC beta functions (β) can be measured using the phase or the amplitude of betatron oscillations obtained with beam position monitors (BPMs). Using the amplitude information results in a β measurement affected by BPM calibration. This work aims at calibrating BPMs using optics measurements. For this, βs from amplitude and phase and normalized dispersion obtained from many different measurements in 2015 with different optics and corrections are analyzed. Simulations are also performed to support the analyses. |
id | oai-inspirehep.net-1470484 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | oai-inspirehep.net-14704842022-08-10T12:48:17Zdoi:10.18429/JACoW-IPAC2016-THPMB041http://cds.cern.ch/record/2207435engGarcia-Tabares, AnaCarlier, FelixCoello de Portugal, Jaime MariaLangner, AndyMaclean, EwenMalina, LukasPersson, TobiasSkowroński, PiotrSolfaroli Camillocci, MatteoTomás, RogelioOptics-measurement-based BPM CalibrationAccelerators and Storage RingsThe LHC beta functions (β) can be measured using the phase or the amplitude of betatron oscillations obtained with beam position monitors (BPMs). Using the amplitude information results in a β measurement affected by BPM calibration. This work aims at calibrating BPMs using optics measurements. For this, βs from amplitude and phase and normalized dispersion obtained from many different measurements in 2015 with different optics and corrections are analyzed. Simulations are also performed to support the analyses.CERN-ACC-2016-188oai:inspirehep.net:14704842016 |
spellingShingle | Accelerators and Storage Rings Garcia-Tabares, Ana Carlier, Felix Coello de Portugal, Jaime Maria Langner, Andy Maclean, Ewen Malina, Lukas Persson, Tobias Skowroński, Piotr Solfaroli Camillocci, Matteo Tomás, Rogelio Optics-measurement-based BPM Calibration |
title | Optics-measurement-based BPM Calibration |
title_full | Optics-measurement-based BPM Calibration |
title_fullStr | Optics-measurement-based BPM Calibration |
title_full_unstemmed | Optics-measurement-based BPM Calibration |
title_short | Optics-measurement-based BPM Calibration |
title_sort | optics-measurement-based bpm calibration |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.18429/JACoW-IPAC2016-THPMB041 http://cds.cern.ch/record/2207435 |
work_keys_str_mv | AT garciatabaresana opticsmeasurementbasedbpmcalibration AT carlierfelix opticsmeasurementbasedbpmcalibration AT coellodeportugaljaimemaria opticsmeasurementbasedbpmcalibration AT langnerandy opticsmeasurementbasedbpmcalibration AT macleanewen opticsmeasurementbasedbpmcalibration AT malinalukas opticsmeasurementbasedbpmcalibration AT perssontobias opticsmeasurementbasedbpmcalibration AT skowronskipiotr opticsmeasurementbasedbpmcalibration AT solfarolicamilloccimatteo opticsmeasurementbasedbpmcalibration AT tomasrogelio opticsmeasurementbasedbpmcalibration |