Cargando…
Comparison of Optics Measurement Methods in ESRF
The N-BPM and the Amplitude methods, which are used in the LHC for beam optics measurement, were applied to the ESRF storage ring. We compare the results to the Orbit Response Matrix (ORM) method that is routinely used in the ESRF. These techniques are conceptually different since the ORM is based o...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2016-THPMB045 http://cds.cern.ch/record/2207439 |
_version_ | 1780951701631533056 |
---|---|
author | Malina, Lukas Coello de Portugal, Jaime Maria Farvacque, Laurent Franchi, Andrea Langner, Andy Persson, Tobias Skowroński, Piotr Tomás, Rogelio |
author_facet | Malina, Lukas Coello de Portugal, Jaime Maria Farvacque, Laurent Franchi, Andrea Langner, Andy Persson, Tobias Skowroński, Piotr Tomás, Rogelio |
author_sort | Malina, Lukas |
collection | CERN |
description | The N-BPM and the Amplitude methods, which are used in the LHC for beam optics measurement, were applied to the ESRF storage ring. We compare the results to the Orbit Response Matrix (ORM) method that is routinely used in the ESRF. These techniques are conceptually different since the ORM is based on the orbit response upon strength variation of steering magnets while the LHC techniques rely on the harmonic analysis of turn-by-turn position excited by a kicker or an AC dipole. Finally, we compare these methods and show the differences in their performance in the ESRF environment. |
id | oai-inspirehep.net-1470488 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | oai-inspirehep.net-14704882022-08-10T12:48:18Zdoi:10.18429/JACoW-IPAC2016-THPMB045http://cds.cern.ch/record/2207439engMalina, LukasCoello de Portugal, Jaime MariaFarvacque, LaurentFranchi, AndreaLangner, AndyPersson, TobiasSkowroński, PiotrTomás, RogelioComparison of Optics Measurement Methods in ESRFAccelerators and Storage RingsThe N-BPM and the Amplitude methods, which are used in the LHC for beam optics measurement, were applied to the ESRF storage ring. We compare the results to the Orbit Response Matrix (ORM) method that is routinely used in the ESRF. These techniques are conceptually different since the ORM is based on the orbit response upon strength variation of steering magnets while the LHC techniques rely on the harmonic analysis of turn-by-turn position excited by a kicker or an AC dipole. Finally, we compare these methods and show the differences in their performance in the ESRF environment.CERN-ACC-2016-184oai:inspirehep.net:14704882016 |
spellingShingle | Accelerators and Storage Rings Malina, Lukas Coello de Portugal, Jaime Maria Farvacque, Laurent Franchi, Andrea Langner, Andy Persson, Tobias Skowroński, Piotr Tomás, Rogelio Comparison of Optics Measurement Methods in ESRF |
title | Comparison of Optics Measurement Methods in ESRF |
title_full | Comparison of Optics Measurement Methods in ESRF |
title_fullStr | Comparison of Optics Measurement Methods in ESRF |
title_full_unstemmed | Comparison of Optics Measurement Methods in ESRF |
title_short | Comparison of Optics Measurement Methods in ESRF |
title_sort | comparison of optics measurement methods in esrf |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.18429/JACoW-IPAC2016-THPMB045 http://cds.cern.ch/record/2207439 |
work_keys_str_mv | AT malinalukas comparisonofopticsmeasurementmethodsinesrf AT coellodeportugaljaimemaria comparisonofopticsmeasurementmethodsinesrf AT farvacquelaurent comparisonofopticsmeasurementmethodsinesrf AT franchiandrea comparisonofopticsmeasurementmethodsinesrf AT langnerandy comparisonofopticsmeasurementmethodsinesrf AT perssontobias comparisonofopticsmeasurementmethodsinesrf AT skowronskipiotr comparisonofopticsmeasurementmethodsinesrf AT tomasrogelio comparisonofopticsmeasurementmethodsinesrf |