Cargando…

Quality tests for SM1 MicroMegas detector module

The Phase-I ATLAS upgrade (2018) aims to improve the detector performance at high luminosity (2 × 10$^{34}$ cm$^{−2}s$^{−1}$). In particular, the upgrade of the muon spectrometer focuses on the Small Wheels (SW) in the end-cap region, which cover 1.3 < |η| < 2.7. The SW will be replaced by the...

Descripción completa

Detalles Bibliográficos
Autor principal: Del Gaudio, M
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.1393/ncc/i2016-16255-4
http://cds.cern.ch/record/2282358
_version_ 1780955701806366720
author Del Gaudio, M
author_facet Del Gaudio, M
author_sort Del Gaudio, M
collection CERN
description The Phase-I ATLAS upgrade (2018) aims to improve the detector performance at high luminosity (2 × 10$^{34}$ cm$^{−2}s$^{−1}$). In particular, the upgrade of the muon spectrometer focuses on the Small Wheels (SW) in the end-cap region, which cover 1.3 < |η| < 2.7. The SW will be replaced by the New Small Wheels (NSW), which is a set of precision tracking and trigger detectors able to work at high rates with excellent real-time spatial and time resolution. Each NSW will be constituted by multiplet of planar gaseous detectors, with trapezoidal shape: smallstrip Thin Gap Chamber (sTGC) and Micro-MEsh Gaseous Structure (MM). This paper describes some of the quality controls that the MM detectors must comply: planarity, thickness and gas tightness.
id oai-inspirehep.net-1485936
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-14859362019-09-30T06:29:59Zdoi:10.1393/ncc/i2016-16255-4http://cds.cern.ch/record/2282358engDel Gaudio, MQuality tests for SM1 MicroMegas detector moduleDetectors and Experimental TechniquesThe Phase-I ATLAS upgrade (2018) aims to improve the detector performance at high luminosity (2 × 10$^{34}$ cm$^{−2}s$^{−1}$). In particular, the upgrade of the muon spectrometer focuses on the Small Wheels (SW) in the end-cap region, which cover 1.3 < |η| < 2.7. The SW will be replaced by the New Small Wheels (NSW), which is a set of precision tracking and trigger detectors able to work at high rates with excellent real-time spatial and time resolution. Each NSW will be constituted by multiplet of planar gaseous detectors, with trapezoidal shape: smallstrip Thin Gap Chamber (sTGC) and Micro-MEsh Gaseous Structure (MM). This paper describes some of the quality controls that the MM detectors must comply: planarity, thickness and gas tightness.oai:inspirehep.net:14859362016
spellingShingle Detectors and Experimental Techniques
Del Gaudio, M
Quality tests for SM1 MicroMegas detector module
title Quality tests for SM1 MicroMegas detector module
title_full Quality tests for SM1 MicroMegas detector module
title_fullStr Quality tests for SM1 MicroMegas detector module
title_full_unstemmed Quality tests for SM1 MicroMegas detector module
title_short Quality tests for SM1 MicroMegas detector module
title_sort quality tests for sm1 micromegas detector module
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1393/ncc/i2016-16255-4
http://cds.cern.ch/record/2282358
work_keys_str_mv AT delgaudiom qualitytestsforsm1micromegasdetectormodule