Cargando…

MPX detectors as LHC luminosity monitor

A network of 16 Medipix-2 (MPX) silicon pixel devices was installed in the ATLAS detector cavern at CERN. It was designed to measure the composition and spectral characteristics of the radiation field in the ATLAS experiment and its surroundings. This study demonstrates that the MPX network can also...

Descripción completa

Detalles Bibliográficos
Autores principales: Sopczak, Andre, Ali, Babar, Asbah, Nedaa, Bergmann, Benedikt, Bekhouche, Khaled, Caforio, Davide, Campbell, Michael, Heijne, Erik, Leroy, Claude, Lipniacka, Anna, Nessi, Marzio, Pospisil, Stanislav, Seifert, Frank, Solc, Jaroslav, Soueid, Paul, Suk, Michal, Turecek, Daniel, Vykydal, Zdenek
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.1109/NSSMIC.2015.7581870
http://cds.cern.ch/record/2263731
_version_ 1780954314552901632
author Sopczak, Andre
Ali, Babar
Asbah, Nedaa
Bergmann, Benedikt
Bekhouche, Khaled
Caforio, Davide
Campbell, Michael
Heijne, Erik
Leroy, Claude
Lipniacka, Anna
Nessi, Marzio
Pospisil, Stanislav
Seifert, Frank
Solc, Jaroslav
Soueid, Paul
Suk, Michal
Turecek, Daniel
Vykydal, Zdenek
author_facet Sopczak, Andre
Ali, Babar
Asbah, Nedaa
Bergmann, Benedikt
Bekhouche, Khaled
Caforio, Davide
Campbell, Michael
Heijne, Erik
Leroy, Claude
Lipniacka, Anna
Nessi, Marzio
Pospisil, Stanislav
Seifert, Frank
Solc, Jaroslav
Soueid, Paul
Suk, Michal
Turecek, Daniel
Vykydal, Zdenek
author_sort Sopczak, Andre
collection CERN
description A network of 16 Medipix-2 (MPX) silicon pixel devices was installed in the ATLAS detector cavern at CERN. It was designed to measure the composition and spectral characteristics of the radiation field in the ATLAS experiment and its surroundings. This study demonstrates that the MPX network can also be used as a self-sufficient luminosity monitoring system. The MPX detectors collect data independently of the ATLAS data-recording chain, and thus they provide independent measurements of the bunch-integrated ATLAS/LHC luminosity. In particular, the MPX detectors located close enough to the primary interaction point are used to perform van der Meer calibration scans with high precision. Results from the luminosity monitoring are presented for 2012 data taken at √s = 8 TeV proton-proton collisions. The characteristics of the LHC luminosity reduction rate are studied and the effects of beam-beam (burn-off) and beam-gas (single bunch) interactions are evaluated. The systematic variations observed in the MPX luminosity measurements are below 0.3% for one minute intervals.
id oai-inspirehep.net-1498877
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-14988772019-09-30T06:29:59Zdoi:10.1109/NSSMIC.2015.7581870http://cds.cern.ch/record/2263731engSopczak, AndreAli, BabarAsbah, NedaaBergmann, BenediktBekhouche, KhaledCaforio, DavideCampbell, MichaelHeijne, ErikLeroy, ClaudeLipniacka, AnnaNessi, MarzioPospisil, StanislavSeifert, FrankSolc, JaroslavSoueid, PaulSuk, MichalTurecek, DanielVykydal, ZdenekMPX detectors as LHC luminosity monitorDetectors and Experimental TechniquesA network of 16 Medipix-2 (MPX) silicon pixel devices was installed in the ATLAS detector cavern at CERN. It was designed to measure the composition and spectral characteristics of the radiation field in the ATLAS experiment and its surroundings. This study demonstrates that the MPX network can also be used as a self-sufficient luminosity monitoring system. The MPX detectors collect data independently of the ATLAS data-recording chain, and thus they provide independent measurements of the bunch-integrated ATLAS/LHC luminosity. In particular, the MPX detectors located close enough to the primary interaction point are used to perform van der Meer calibration scans with high precision. Results from the luminosity monitoring are presented for 2012 data taken at √s = 8 TeV proton-proton collisions. The characteristics of the LHC luminosity reduction rate are studied and the effects of beam-beam (burn-off) and beam-gas (single bunch) interactions are evaluated. The systematic variations observed in the MPX luminosity measurements are below 0.3% for one minute intervals.oai:inspirehep.net:14988772016
spellingShingle Detectors and Experimental Techniques
Sopczak, Andre
Ali, Babar
Asbah, Nedaa
Bergmann, Benedikt
Bekhouche, Khaled
Caforio, Davide
Campbell, Michael
Heijne, Erik
Leroy, Claude
Lipniacka, Anna
Nessi, Marzio
Pospisil, Stanislav
Seifert, Frank
Solc, Jaroslav
Soueid, Paul
Suk, Michal
Turecek, Daniel
Vykydal, Zdenek
MPX detectors as LHC luminosity monitor
title MPX detectors as LHC luminosity monitor
title_full MPX detectors as LHC luminosity monitor
title_fullStr MPX detectors as LHC luminosity monitor
title_full_unstemmed MPX detectors as LHC luminosity monitor
title_short MPX detectors as LHC luminosity monitor
title_sort mpx detectors as lhc luminosity monitor
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/NSSMIC.2015.7581870
http://cds.cern.ch/record/2263731
work_keys_str_mv AT sopczakandre mpxdetectorsaslhcluminositymonitor
AT alibabar mpxdetectorsaslhcluminositymonitor
AT asbahnedaa mpxdetectorsaslhcluminositymonitor
AT bergmannbenedikt mpxdetectorsaslhcluminositymonitor
AT bekhouchekhaled mpxdetectorsaslhcluminositymonitor
AT caforiodavide mpxdetectorsaslhcluminositymonitor
AT campbellmichael mpxdetectorsaslhcluminositymonitor
AT heijneerik mpxdetectorsaslhcluminositymonitor
AT leroyclaude mpxdetectorsaslhcluminositymonitor
AT lipniackaanna mpxdetectorsaslhcluminositymonitor
AT nessimarzio mpxdetectorsaslhcluminositymonitor
AT pospisilstanislav mpxdetectorsaslhcluminositymonitor
AT seifertfrank mpxdetectorsaslhcluminositymonitor
AT solcjaroslav mpxdetectorsaslhcluminositymonitor
AT soueidpaul mpxdetectorsaslhcluminositymonitor
AT sukmichal mpxdetectorsaslhcluminositymonitor
AT turecekdaniel mpxdetectorsaslhcluminositymonitor
AT vykydalzdenek mpxdetectorsaslhcluminositymonitor