Cargando…

Higher‐order mode absorption measurement of X-band choke-mode cavities in a radial line structure

An experiment is presented to study the higher-order mode (HOM) suppression of X-band choke-mode structures with a vector network analyzer (VNA). Specific radial line disks were built to test the reflection from the corresponding damping load and different choke geometries. The mismatch between the...

Descripción completa

Detalles Bibliográficos
Autores principales: Zha, Hao, Shi, Jiaru, Wu, Xiaowei, Chen, Huaibi
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2016.01.047
http://cds.cern.ch/record/2265749
_version_ 1780954519272685568
author Zha, Hao
Shi, Jiaru
Wu, Xiaowei
Chen, Huaibi
author_facet Zha, Hao
Shi, Jiaru
Wu, Xiaowei
Chen, Huaibi
author_sort Zha, Hao
collection CERN
description An experiment is presented to study the higher-order mode (HOM) suppression of X-band choke-mode structures with a vector network analyzer (VNA). Specific radial line disks were built to test the reflection from the corresponding damping load and different choke geometries. The mismatch between the radial lines and the VNA was calibrated through a special multi-short-load calibration method. The measured reflections of different choke geometries showed good agreement with the theoretical calculations and verified the HOM absorption feature of each geometric design.
id oai-inspirehep.net-1600636
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-16006362019-09-30T06:29:59Zdoi:10.1016/j.nima.2016.01.047http://cds.cern.ch/record/2265749engZha, HaoShi, JiaruWu, XiaoweiChen, HuaibiHigher‐order mode absorption measurement of X-band choke-mode cavities in a radial line structureDetectors and Experimental TechniquesAn experiment is presented to study the higher-order mode (HOM) suppression of X-band choke-mode structures with a vector network analyzer (VNA). Specific radial line disks were built to test the reflection from the corresponding damping load and different choke geometries. The mismatch between the radial lines and the VNA was calibrated through a special multi-short-load calibration method. The measured reflections of different choke geometries showed good agreement with the theoretical calculations and verified the HOM absorption feature of each geometric design.oai:inspirehep.net:16006362016
spellingShingle Detectors and Experimental Techniques
Zha, Hao
Shi, Jiaru
Wu, Xiaowei
Chen, Huaibi
Higher‐order mode absorption measurement of X-band choke-mode cavities in a radial line structure
title Higher‐order mode absorption measurement of X-band choke-mode cavities in a radial line structure
title_full Higher‐order mode absorption measurement of X-band choke-mode cavities in a radial line structure
title_fullStr Higher‐order mode absorption measurement of X-band choke-mode cavities in a radial line structure
title_full_unstemmed Higher‐order mode absorption measurement of X-band choke-mode cavities in a radial line structure
title_short Higher‐order mode absorption measurement of X-band choke-mode cavities in a radial line structure
title_sort higher‐order mode absorption measurement of x-band choke-mode cavities in a radial line structure
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2016.01.047
http://cds.cern.ch/record/2265749
work_keys_str_mv AT zhahao higherordermodeabsorptionmeasurementofxbandchokemodecavitiesinaradiallinestructure
AT shijiaru higherordermodeabsorptionmeasurementofxbandchokemodecavitiesinaradiallinestructure
AT wuxiaowei higherordermodeabsorptionmeasurementofxbandchokemodecavitiesinaradiallinestructure
AT chenhuaibi higherordermodeabsorptionmeasurementofxbandchokemodecavitiesinaradiallinestructure