During the operational life of a PET Cyclotron, the concrete walls of the cyclotron vault are activated by the secondary neutron flux interacting with rare earths and metals present in the concrete or in reinforcement bars. For this reason when considering dismantling of such accelerators, the amoun...

Descripción completa

Detalles Bibliográficos
Autores principales: Vichi, Sara, Infantino, Angelo, Zagni, Federico, Cicoria, Gianfranco, Marengo, Mario, Mostacci, Domiziano
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.1080/10420150.2016.1244675
http://cds.cern.ch/record/2267914
_version_ 1780954708465156096
author Vichi, Sara
Infantino, Angelo
Zagni, Federico
Cicoria, Gianfranco
Marengo, Mario
Mostacci, Domiziano
author_facet Vichi, Sara
Infantino, Angelo
Zagni, Federico
Cicoria, Gianfranco
Marengo, Mario
Mostacci, Domiziano
author_sort Vichi, Sara
collection CERN
description During the operational life of a PET Cyclotron, the concrete walls of the cyclotron vault are activated by the secondary neutron flux interacting with rare earths and metals present in the concrete or in reinforcement bars. For this reason when considering dismantling of such accelerators, the amount of radioactive waste has to be evaluated in advance to identify any critical issues or possible countermeasures to be taken to define an optimum decommissioning strategy. The aim of this work is to define a non-destructive in situ measurement methodology for a preliminary activation assessment of a cyclotron bunker with no need for core drilling. A very compact, USB-powered, CdZnTe (CZT) detector for gamma-ray spectrometry was used for the activation assessment of the site of installation of a GE PETtrace (16.5MeV) cyclotron, routinely used in the production of positron-emitting radionuclides. Because of the complexity of measurement geometry, the efficiency calibration of the detector was performed via Monte Carlo (MC) simulations. The detector was accurately modelled using FLUKA, including a 5cm lead shielding set-up. The MC model of the detector was validated for a wide range of energies and different source geometries, showing discrepancies below 5% for all tested sources. The efficiency curve for wall activation measurements was calculated, allowing a quantitative evaluation of activity concentration.
id oai-inspirehep.net-1602723
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-16027232019-09-30T06:29:59Zdoi:10.1080/10420150.2016.1244675http://cds.cern.ch/record/2267914engVichi, SaraInfantino, AngeloZagni, FedericoCicoria, GianfrancoMarengo, MarioMostacci, DomizianoEfficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunkerDetectors and Experimental TechniquesDuring the operational life of a PET Cyclotron, the concrete walls of the cyclotron vault are activated by the secondary neutron flux interacting with rare earths and metals present in the concrete or in reinforcement bars. For this reason when considering dismantling of such accelerators, the amount of radioactive waste has to be evaluated in advance to identify any critical issues or possible countermeasures to be taken to define an optimum decommissioning strategy. The aim of this work is to define a non-destructive in situ measurement methodology for a preliminary activation assessment of a cyclotron bunker with no need for core drilling. A very compact, USB-powered, CdZnTe (CZT) detector for gamma-ray spectrometry was used for the activation assessment of the site of installation of a GE PETtrace (16.5MeV) cyclotron, routinely used in the production of positron-emitting radionuclides. Because of the complexity of measurement geometry, the efficiency calibration of the detector was performed via Monte Carlo (MC) simulations. The detector was accurately modelled using FLUKA, including a 5cm lead shielding set-up. The MC model of the detector was validated for a wide range of energies and different source geometries, showing discrepancies below 5% for all tested sources. The efficiency curve for wall activation measurements was calculated, allowing a quantitative evaluation of activity concentration.oai:inspirehep.net:16027232016
spellingShingle Detectors and Experimental Techniques
Vichi, Sara
Infantino, Angelo
Zagni, Federico
Cicoria, Gianfranco
Marengo, Mario
Mostacci, Domiziano
Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker
title Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker
title_full Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker
title_fullStr Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker
title_full_unstemmed Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker
title_short Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker
title_sort efficiency calibration of a portable czt detector for nondestructive activation assessment of a cyclotron bunker
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1080/10420150.2016.1244675
http://cds.cern.ch/record/2267914
work_keys_str_mv AT vichisara efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker
AT infantinoangelo efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker
AT zagnifederico efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker
AT cicoriagianfranco efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker
AT marengomario efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker
AT mostaccidomiziano efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker