Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker
During the operational life of a PET Cyclotron, the concrete walls of the cyclotron vault are activated by the secondary neutron flux interacting with rare earths and metals present in the concrete or in reinforcement bars. For this reason when considering dismantling of such accelerators, the amoun...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1080/10420150.2016.1244675 http://cds.cern.ch/record/2267914 |
_version_ | 1780954708465156096 |
---|---|
author | Vichi, Sara Infantino, Angelo Zagni, Federico Cicoria, Gianfranco Marengo, Mario Mostacci, Domiziano |
author_facet | Vichi, Sara Infantino, Angelo Zagni, Federico Cicoria, Gianfranco Marengo, Mario Mostacci, Domiziano |
author_sort | Vichi, Sara |
collection | CERN |
description | During the operational life of a PET Cyclotron, the concrete walls of the cyclotron vault are activated by the secondary neutron flux interacting with rare earths and metals present in the concrete or in reinforcement bars. For this reason when considering dismantling of such accelerators, the amount of radioactive waste has to be evaluated in advance to identify any critical issues or possible countermeasures to be taken to define an optimum decommissioning strategy. The aim of this work is to define a non-destructive in situ measurement methodology for a preliminary activation assessment of a cyclotron bunker with no need for core drilling. A very compact, USB-powered, CdZnTe (CZT) detector for gamma-ray spectrometry was used for the activation assessment of the site of installation of a GE PETtrace (16.5MeV) cyclotron, routinely used in the production of positron-emitting radionuclides. Because of the complexity of measurement geometry, the efficiency calibration of the detector was performed via Monte Carlo (MC) simulations. The detector was accurately modelled using FLUKA, including a 5cm lead shielding set-up. The MC model of the detector was validated for a wide range of energies and different source geometries, showing discrepancies below 5% for all tested sources. The efficiency curve for wall activation measurements was calculated, allowing a quantitative evaluation of activity concentration. |
id | oai-inspirehep.net-1602723 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | oai-inspirehep.net-16027232019-09-30T06:29:59Zdoi:10.1080/10420150.2016.1244675http://cds.cern.ch/record/2267914engVichi, SaraInfantino, AngeloZagni, FedericoCicoria, GianfrancoMarengo, MarioMostacci, DomizianoEfficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunkerDetectors and Experimental TechniquesDuring the operational life of a PET Cyclotron, the concrete walls of the cyclotron vault are activated by the secondary neutron flux interacting with rare earths and metals present in the concrete or in reinforcement bars. For this reason when considering dismantling of such accelerators, the amount of radioactive waste has to be evaluated in advance to identify any critical issues or possible countermeasures to be taken to define an optimum decommissioning strategy. The aim of this work is to define a non-destructive in situ measurement methodology for a preliminary activation assessment of a cyclotron bunker with no need for core drilling. A very compact, USB-powered, CdZnTe (CZT) detector for gamma-ray spectrometry was used for the activation assessment of the site of installation of a GE PETtrace (16.5MeV) cyclotron, routinely used in the production of positron-emitting radionuclides. Because of the complexity of measurement geometry, the efficiency calibration of the detector was performed via Monte Carlo (MC) simulations. The detector was accurately modelled using FLUKA, including a 5cm lead shielding set-up. The MC model of the detector was validated for a wide range of energies and different source geometries, showing discrepancies below 5% for all tested sources. The efficiency curve for wall activation measurements was calculated, allowing a quantitative evaluation of activity concentration.oai:inspirehep.net:16027232016 |
spellingShingle | Detectors and Experimental Techniques Vichi, Sara Infantino, Angelo Zagni, Federico Cicoria, Gianfranco Marengo, Mario Mostacci, Domiziano Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker |
title | Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker |
title_full | Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker |
title_fullStr | Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker |
title_full_unstemmed | Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker |
title_short | Efficiency calibration of a portable CZT detector for nondestructive activation assessment of a cyclotron bunker |
title_sort | efficiency calibration of a portable czt detector for nondestructive activation assessment of a cyclotron bunker |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1080/10420150.2016.1244675 http://cds.cern.ch/record/2267914 |
work_keys_str_mv | AT vichisara efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker AT infantinoangelo efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker AT zagnifederico efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker AT cicoriagianfranco efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker AT marengomario efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker AT mostaccidomiziano efficiencycalibrationofaportablecztdetectorfornondestructiveactivationassessmentofacyclotronbunker |