Cargando…
SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE
The formation of secondary high-energy neutrons in proton therapy can be a concern for radiation protection of staff. In this joint intercomparative study (CERN, SCK•CEN and IBA/IRISIB/ULB), secondary neutron doses were assessed with different detectors in several positions in the Proton Therapy Cen...
Autores principales: | , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1093/rpd/ncv458 http://cds.cern.ch/record/2268696 |
_version_ | 1780954711744053248 |
---|---|
author | De Saint-Hubert, M Saldarriaga Vargas, C Van Hoey, O Schoonjans, W De Smet, V Mathot, G Stichelbaut, F Manessi, G Dinar, N Aza, E Cassell, C Silari, M Vanhavere, F |
author_facet | De Saint-Hubert, M Saldarriaga Vargas, C Van Hoey, O Schoonjans, W De Smet, V Mathot, G Stichelbaut, F Manessi, G Dinar, N Aza, E Cassell, C Silari, M Vanhavere, F |
author_sort | De Saint-Hubert, M |
collection | CERN |
description | The formation of secondary high-energy neutrons in proton therapy can be a concern for radiation protection of staff. In this joint intercomparative study (CERN, SCK•CEN and IBA/IRISIB/ULB), secondary neutron doses were assessed with different detectors in several positions in the Proton Therapy Centre, Essen (Germany). The ambient dose equivalent H*(10) was assessed with Berthold LB 6411, WENDI-2, tissue-equivalent proportional counter (TEPC) and Bonner spheres (BS). The personal dose equivalent Hp(10) was measured with two types of active detectors and with bubble detectors. Using spectral and basic angular information, the reference Hp(10) was estimated. Results concerning staff exposure show $H^*$(10) doses between 0.5 and 1 nSv/monitoring unit in a technical room. The LB 6411 showed an underestimation of $H^*$(10), while WENDI-2 and TEPC showed good agreement with the BS data. A large overestimation for Hp(10) was observed for the active personal dosemeters, while the bubble detectors showed only a slight overestimation. |
id | oai-inspirehep.net-1603027 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | oai-inspirehep.net-16030272019-09-30T06:29:59Zdoi:10.1093/rpd/ncv458http://cds.cern.ch/record/2268696engDe Saint-Hubert, MSaldarriaga Vargas, CVan Hoey, OSchoonjans, WDe Smet, VMathot, GStichelbaut, FManessi, GDinar, NAza, ECassell, CSilari, MVanhavere, FSECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTREDetectors and Experimental TechniquesThe formation of secondary high-energy neutrons in proton therapy can be a concern for radiation protection of staff. In this joint intercomparative study (CERN, SCK•CEN and IBA/IRISIB/ULB), secondary neutron doses were assessed with different detectors in several positions in the Proton Therapy Centre, Essen (Germany). The ambient dose equivalent H*(10) was assessed with Berthold LB 6411, WENDI-2, tissue-equivalent proportional counter (TEPC) and Bonner spheres (BS). The personal dose equivalent Hp(10) was measured with two types of active detectors and with bubble detectors. Using spectral and basic angular information, the reference Hp(10) was estimated. Results concerning staff exposure show $H^*$(10) doses between 0.5 and 1 nSv/monitoring unit in a technical room. The LB 6411 showed an underestimation of $H^*$(10), while WENDI-2 and TEPC showed good agreement with the BS data. A large overestimation for Hp(10) was observed for the active personal dosemeters, while the bubble detectors showed only a slight overestimation.oai:inspirehep.net:16030272016 |
spellingShingle | Detectors and Experimental Techniques De Saint-Hubert, M Saldarriaga Vargas, C Van Hoey, O Schoonjans, W De Smet, V Mathot, G Stichelbaut, F Manessi, G Dinar, N Aza, E Cassell, C Silari, M Vanhavere, F SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE |
title | SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE |
title_full | SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE |
title_fullStr | SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE |
title_full_unstemmed | SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE |
title_short | SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE |
title_sort | secondary neutron doses in a proton therapy centre |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1093/rpd/ncv458 http://cds.cern.ch/record/2268696 |
work_keys_str_mv | AT desainthubertm secondaryneutrondosesinaprotontherapycentre AT saldarriagavargasc secondaryneutrondosesinaprotontherapycentre AT vanhoeyo secondaryneutrondosesinaprotontherapycentre AT schoonjansw secondaryneutrondosesinaprotontherapycentre AT desmetv secondaryneutrondosesinaprotontherapycentre AT mathotg secondaryneutrondosesinaprotontherapycentre AT stichelbautf secondaryneutrondosesinaprotontherapycentre AT manessig secondaryneutrondosesinaprotontherapycentre AT dinarn secondaryneutrondosesinaprotontherapycentre AT azae secondaryneutrondosesinaprotontherapycentre AT cassellc secondaryneutrondosesinaprotontherapycentre AT silarim secondaryneutrondosesinaprotontherapycentre AT vanhaveref secondaryneutrondosesinaprotontherapycentre |