Cargando…

SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE

The formation of secondary high-energy neutrons in proton therapy can be a concern for radiation protection of staff. In this joint intercomparative study (CERN, SCK•CEN and IBA/IRISIB/ULB), secondary neutron doses were assessed with different detectors in several positions in the Proton Therapy Cen...

Descripción completa

Detalles Bibliográficos
Autores principales: De Saint-Hubert, M, Saldarriaga Vargas, C, Van Hoey, O, Schoonjans, W, De Smet, V, Mathot, G, Stichelbaut, F, Manessi, G, Dinar, N, Aza, E, Cassell, C, Silari, M, Vanhavere, F
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.1093/rpd/ncv458
http://cds.cern.ch/record/2268696
_version_ 1780954711744053248
author De Saint-Hubert, M
Saldarriaga Vargas, C
Van Hoey, O
Schoonjans, W
De Smet, V
Mathot, G
Stichelbaut, F
Manessi, G
Dinar, N
Aza, E
Cassell, C
Silari, M
Vanhavere, F
author_facet De Saint-Hubert, M
Saldarriaga Vargas, C
Van Hoey, O
Schoonjans, W
De Smet, V
Mathot, G
Stichelbaut, F
Manessi, G
Dinar, N
Aza, E
Cassell, C
Silari, M
Vanhavere, F
author_sort De Saint-Hubert, M
collection CERN
description The formation of secondary high-energy neutrons in proton therapy can be a concern for radiation protection of staff. In this joint intercomparative study (CERN, SCK•CEN and IBA/IRISIB/ULB), secondary neutron doses were assessed with different detectors in several positions in the Proton Therapy Centre, Essen (Germany). The ambient dose equivalent H*(10) was assessed with Berthold LB 6411, WENDI-2, tissue-equivalent proportional counter (TEPC) and Bonner spheres (BS). The personal dose equivalent Hp(10) was measured with two types of active detectors and with bubble detectors. Using spectral and basic angular information, the reference Hp(10) was estimated. Results concerning staff exposure show $H^*$(10) doses between 0.5 and 1 nSv/monitoring unit in a technical room. The LB 6411 showed an underestimation of $H^*$(10), while WENDI-2 and TEPC showed good agreement with the BS data. A large overestimation for Hp(10) was observed for the active personal dosemeters, while the bubble detectors showed only a slight overestimation.
id oai-inspirehep.net-1603027
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-16030272019-09-30T06:29:59Zdoi:10.1093/rpd/ncv458http://cds.cern.ch/record/2268696engDe Saint-Hubert, MSaldarriaga Vargas, CVan Hoey, OSchoonjans, WDe Smet, VMathot, GStichelbaut, FManessi, GDinar, NAza, ECassell, CSilari, MVanhavere, FSECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTREDetectors and Experimental TechniquesThe formation of secondary high-energy neutrons in proton therapy can be a concern for radiation protection of staff. In this joint intercomparative study (CERN, SCK•CEN and IBA/IRISIB/ULB), secondary neutron doses were assessed with different detectors in several positions in the Proton Therapy Centre, Essen (Germany). The ambient dose equivalent H*(10) was assessed with Berthold LB 6411, WENDI-2, tissue-equivalent proportional counter (TEPC) and Bonner spheres (BS). The personal dose equivalent Hp(10) was measured with two types of active detectors and with bubble detectors. Using spectral and basic angular information, the reference Hp(10) was estimated. Results concerning staff exposure show $H^*$(10) doses between 0.5 and 1 nSv/monitoring unit in a technical room. The LB 6411 showed an underestimation of $H^*$(10), while WENDI-2 and TEPC showed good agreement with the BS data. A large overestimation for Hp(10) was observed for the active personal dosemeters, while the bubble detectors showed only a slight overestimation.oai:inspirehep.net:16030272016
spellingShingle Detectors and Experimental Techniques
De Saint-Hubert, M
Saldarriaga Vargas, C
Van Hoey, O
Schoonjans, W
De Smet, V
Mathot, G
Stichelbaut, F
Manessi, G
Dinar, N
Aza, E
Cassell, C
Silari, M
Vanhavere, F
SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE
title SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE
title_full SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE
title_fullStr SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE
title_full_unstemmed SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE
title_short SECONDARY NEUTRON DOSES IN A PROTON THERAPY CENTRE
title_sort secondary neutron doses in a proton therapy centre
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1093/rpd/ncv458
http://cds.cern.ch/record/2268696
work_keys_str_mv AT desainthubertm secondaryneutrondosesinaprotontherapycentre
AT saldarriagavargasc secondaryneutrondosesinaprotontherapycentre
AT vanhoeyo secondaryneutrondosesinaprotontherapycentre
AT schoonjansw secondaryneutrondosesinaprotontherapycentre
AT desmetv secondaryneutrondosesinaprotontherapycentre
AT mathotg secondaryneutrondosesinaprotontherapycentre
AT stichelbautf secondaryneutrondosesinaprotontherapycentre
AT manessig secondaryneutrondosesinaprotontherapycentre
AT dinarn secondaryneutrondosesinaprotontherapycentre
AT azae secondaryneutrondosesinaprotontherapycentre
AT cassellc secondaryneutrondosesinaprotontherapycentre
AT silarim secondaryneutrondosesinaprotontherapycentre
AT vanhaveref secondaryneutrondosesinaprotontherapycentre