Cargando…

Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams

The growing number of particle therapy facilities worldwide landmarks a novel era of precision oncology. Implementation of robust biophysical readouts is urgently needed to assess the efficacy of different radiation qualities. This is the first report on biophysical evaluation of Monte Carlo simulat...

Descripción completa

Detalles Bibliográficos
Autores principales: Dokic, Ivana, Mairani, Andrea, Niklas, Martin, Zimmermann, Ferdinand, Chaudhri, Naved, Krunic, Damir, Tessonnier, Thomas, Ferrari, Alfredo, Parodi, Katia, Jäkel, Oliver, Debus, Jürgen, Haberer, Thomas, Abdollahi, Amir
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.18632/oncotarget.10996
http://cds.cern.ch/record/2268235
_version_ 1780954718127783936
author Dokic, Ivana
Mairani, Andrea
Niklas, Martin
Zimmermann, Ferdinand
Chaudhri, Naved
Krunic, Damir
Tessonnier, Thomas
Ferrari, Alfredo
Parodi, Katia
Jäkel, Oliver
Debus, Jürgen
Haberer, Thomas
Abdollahi, Amir
author_facet Dokic, Ivana
Mairani, Andrea
Niklas, Martin
Zimmermann, Ferdinand
Chaudhri, Naved
Krunic, Damir
Tessonnier, Thomas
Ferrari, Alfredo
Parodi, Katia
Jäkel, Oliver
Debus, Jürgen
Haberer, Thomas
Abdollahi, Amir
author_sort Dokic, Ivana
collection CERN
description The growing number of particle therapy facilities worldwide landmarks a novel era of precision oncology. Implementation of robust biophysical readouts is urgently needed to assess the efficacy of different radiation qualities. This is the first report on biophysical evaluation of Monte Carlo simulated predictive models of prescribed dose for four particle qualities i.e., proton, helium-, carbon- or oxygen ions using raster-scanning technology and clinical therapy settings at HIT. A high level of agreement was found between the in silico simulations, the physical dosimetry and the clonogenic tumor cell survival. The cell fluorescence ion track hybrid detector (Cell-Fit-HD) technology was employed to detect particle traverse per cell nucleus. Across a panel of radiobiological surrogates studied such as late ROS accumulation and apoptosis (caspase 3/7 activation), the relative biological effectiveness (RBE) chiefly correlated with the radiation species-specific spatio-temporal pattern of DNA double strand break (DSB) formation and repair kinetic. The size and the number of residual nuclear γ-H2AX foci increased as a function of linear energy transfer (LET) and RBE, reminiscent of enhanced DNA-damage complexity and accumulation of non-repairable DSB. These data confirm the high relevance of complex DSB formation as a central determinant of cell fate and reliable biological surrogates for cell survival/ RBE. The multi-scale simulation, physical and radiobiological characterization of novel clinical quality beams presented here constitutes a first step towards development of high precision biologically individualized radiotherapy.
id oai-inspirehep.net-1603420
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-16034202019-09-30T06:29:59Zdoi:10.18632/oncotarget.10996http://cds.cern.ch/record/2268235engDokic, IvanaMairani, AndreaNiklas, MartinZimmermann, FerdinandChaudhri, NavedKrunic, DamirTessonnier, ThomasFerrari, AlfredoParodi, KatiaJäkel, OliverDebus, JürgenHaberer, ThomasAbdollahi, AmirNext generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beamsOtherThe growing number of particle therapy facilities worldwide landmarks a novel era of precision oncology. Implementation of robust biophysical readouts is urgently needed to assess the efficacy of different radiation qualities. This is the first report on biophysical evaluation of Monte Carlo simulated predictive models of prescribed dose for four particle qualities i.e., proton, helium-, carbon- or oxygen ions using raster-scanning technology and clinical therapy settings at HIT. A high level of agreement was found between the in silico simulations, the physical dosimetry and the clonogenic tumor cell survival. The cell fluorescence ion track hybrid detector (Cell-Fit-HD) technology was employed to detect particle traverse per cell nucleus. Across a panel of radiobiological surrogates studied such as late ROS accumulation and apoptosis (caspase 3/7 activation), the relative biological effectiveness (RBE) chiefly correlated with the radiation species-specific spatio-temporal pattern of DNA double strand break (DSB) formation and repair kinetic. The size and the number of residual nuclear γ-H2AX foci increased as a function of linear energy transfer (LET) and RBE, reminiscent of enhanced DNA-damage complexity and accumulation of non-repairable DSB. These data confirm the high relevance of complex DSB formation as a central determinant of cell fate and reliable biological surrogates for cell survival/ RBE. The multi-scale simulation, physical and radiobiological characterization of novel clinical quality beams presented here constitutes a first step towards development of high precision biologically individualized radiotherapy.oai:inspirehep.net:16034202016
spellingShingle Other
Dokic, Ivana
Mairani, Andrea
Niklas, Martin
Zimmermann, Ferdinand
Chaudhri, Naved
Krunic, Damir
Tessonnier, Thomas
Ferrari, Alfredo
Parodi, Katia
Jäkel, Oliver
Debus, Jürgen
Haberer, Thomas
Abdollahi, Amir
Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams
title Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams
title_full Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams
title_fullStr Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams
title_full_unstemmed Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams
title_short Next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams
title_sort next generation multi-scale biophysical characterization of high precision cancer particle radiotherapy using clinical proton, helium-, carbon- and oxygen ion beams
topic Other
url https://dx.doi.org/10.18632/oncotarget.10996
http://cds.cern.ch/record/2268235
work_keys_str_mv AT dokicivana nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT mairaniandrea nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT niklasmartin nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT zimmermannferdinand nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT chaudhrinaved nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT krunicdamir nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT tessonnierthomas nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT ferrarialfredo nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT parodikatia nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT jakeloliver nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT debusjurgen nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT habererthomas nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams
AT abdollahiamir nextgenerationmultiscalebiophysicalcharacterizationofhighprecisioncancerparticleradiotherapyusingclinicalprotonheliumcarbonandoxygenionbeams