Cargando…

Synchrotron Microtomography Investigation of the Filament Microstructure in Differently Processed Bi-2212 Wires

The Bi-2212 microstructure and porosity distribution in entire state-of-the-art multifilament wires was characterized by high-energy synchrotron X-ray absorption microtomography after meltprocessing at ambient pressure, at 100 bar overpressure, and at ambient pressure after prior cold isostatic pres...

Descripción completa

Detalles Bibliográficos
Autores principales: Scheuerlein, Christian, Rack, Alexander, Schladitz, Katja, Huwig, Luisa
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TASC.2016.2644539
http://cds.cern.ch/record/2276065
_version_ 1780955270690635776
author Scheuerlein, Christian
Rack, Alexander
Schladitz, Katja
Huwig, Luisa
author_facet Scheuerlein, Christian
Rack, Alexander
Schladitz, Katja
Huwig, Luisa
author_sort Scheuerlein, Christian
collection CERN
description The Bi-2212 microstructure and porosity distribution in entire state-of-the-art multifilament wires was characterized by high-energy synchrotron X-ray absorption microtomography after meltprocessing at ambient pressure, at 100 bar overpressure, and at ambient pressure after prior cold isostatic pressing of initially identical as-drawn wires. Beyond the visualization of the Bi-2212 microstructure, the porosity distribution in the different filament bundles has been quantified. Spherical granulometry and finite percolation probability calculations have been performed in order to provide a measure for the porosity distribution and to compare filament connectivity in the axial wire direction. Possible artifacts of the microtomography (μ-CT) experiment and the possibility to estimate the effect of the Bi-2212 microstructure as seen in the μ-CT images on critical current density are discussed.
id oai-inspirehep.net-1611379
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling oai-inspirehep.net-16113792019-09-30T06:29:59Zdoi:10.1109/TASC.2016.2644539http://cds.cern.ch/record/2276065engScheuerlein, ChristianRack, AlexanderSchladitz, KatjaHuwig, LuisaSynchrotron Microtomography Investigation of the Filament Microstructure in Differently Processed Bi-2212 WiresDetectors and Experimental TechniquesThe Bi-2212 microstructure and porosity distribution in entire state-of-the-art multifilament wires was characterized by high-energy synchrotron X-ray absorption microtomography after meltprocessing at ambient pressure, at 100 bar overpressure, and at ambient pressure after prior cold isostatic pressing of initially identical as-drawn wires. Beyond the visualization of the Bi-2212 microstructure, the porosity distribution in the different filament bundles has been quantified. Spherical granulometry and finite percolation probability calculations have been performed in order to provide a measure for the porosity distribution and to compare filament connectivity in the axial wire direction. Possible artifacts of the microtomography (μ-CT) experiment and the possibility to estimate the effect of the Bi-2212 microstructure as seen in the μ-CT images on critical current density are discussed.oai:inspirehep.net:16113792017
spellingShingle Detectors and Experimental Techniques
Scheuerlein, Christian
Rack, Alexander
Schladitz, Katja
Huwig, Luisa
Synchrotron Microtomography Investigation of the Filament Microstructure in Differently Processed Bi-2212 Wires
title Synchrotron Microtomography Investigation of the Filament Microstructure in Differently Processed Bi-2212 Wires
title_full Synchrotron Microtomography Investigation of the Filament Microstructure in Differently Processed Bi-2212 Wires
title_fullStr Synchrotron Microtomography Investigation of the Filament Microstructure in Differently Processed Bi-2212 Wires
title_full_unstemmed Synchrotron Microtomography Investigation of the Filament Microstructure in Differently Processed Bi-2212 Wires
title_short Synchrotron Microtomography Investigation of the Filament Microstructure in Differently Processed Bi-2212 Wires
title_sort synchrotron microtomography investigation of the filament microstructure in differently processed bi-2212 wires
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/TASC.2016.2644539
http://cds.cern.ch/record/2276065
work_keys_str_mv AT scheuerleinchristian synchrotronmicrotomographyinvestigationofthefilamentmicrostructureindifferentlyprocessedbi2212wires
AT rackalexander synchrotronmicrotomographyinvestigationofthefilamentmicrostructureindifferentlyprocessedbi2212wires
AT schladitzkatja synchrotronmicrotomographyinvestigationofthefilamentmicrostructureindifferentlyprocessedbi2212wires
AT huwigluisa synchrotronmicrotomographyinvestigationofthefilamentmicrostructureindifferentlyprocessedbi2212wires