Cargando…
ISOLTRAP's multi-reflection time-of-flight mass separator/spectrometer
The online precision mass spectrometer ISOLTRAP at ISOLDE/CERN was recently upgraded by adding a multi-reflection time-of-flight mass separator/spectrometer (MR-ToF MS) between the linear radio-frequency ion trap and the two Penning traps already in place. As a mass separator, the MR-ToF device has...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2013
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.ijms.2013.03.020 http://cds.cern.ch/record/2279141 |
_version_ | 1780955430606864384 |
---|---|
author | Wolf, R N Wienholtz, F Atanasov, D Beck, D Blaum, K Borgmann, Ch Herfurth, F Kowalska, M Kreim, S Litvinov, Yu A Lunney, D Manea, V Neidherr, D Rosenbusch, M Schweikhard, L Stanja, J Zuber, K |
author_facet | Wolf, R N Wienholtz, F Atanasov, D Beck, D Blaum, K Borgmann, Ch Herfurth, F Kowalska, M Kreim, S Litvinov, Yu A Lunney, D Manea, V Neidherr, D Rosenbusch, M Schweikhard, L Stanja, J Zuber, K |
author_sort | Wolf, R N |
collection | CERN |
description | The online precision mass spectrometer ISOLTRAP at ISOLDE/CERN was recently upgraded by adding a multi-reflection time-of-flight mass separator/spectrometer (MR-ToF MS) between the linear radio-frequency ion trap and the two Penning traps already in place. As a mass separator, the MR-ToF device has improved significantly ISOLTRAP's capability of purification of contaminated ion beams. In addition, the MR-ToF MS can be operated as a mass spectrometer, either to analyze the ISOLDE ion beam or for precision mass measurements of nuclides that are shorter-lived or that have lower yields than those accessible for Penning-trap mass spectrometry. The MR-ToF MS and corresponding components, its integration into ISOLTRAP, and its various operation modes are reviewed. Furthermore, a precision measurement of the 137Eu mass is presented, determined with the help of the MR-ToF device as a mass separator. |
id | oai-inspirehep.net-1615926 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2013 |
record_format | invenio |
spelling | oai-inspirehep.net-16159262019-09-30T06:29:59Zdoi:10.1016/j.ijms.2013.03.020http://cds.cern.ch/record/2279141engWolf, R NWienholtz, FAtanasov, DBeck, DBlaum, KBorgmann, ChHerfurth, FKowalska, MKreim, SLitvinov, Yu ALunney, DManea, VNeidherr, DRosenbusch, MSchweikhard, LStanja, JZuber, KISOLTRAP's multi-reflection time-of-flight mass separator/spectrometerDetectors and Experimental TechniquesThe online precision mass spectrometer ISOLTRAP at ISOLDE/CERN was recently upgraded by adding a multi-reflection time-of-flight mass separator/spectrometer (MR-ToF MS) between the linear radio-frequency ion trap and the two Penning traps already in place. As a mass separator, the MR-ToF device has improved significantly ISOLTRAP's capability of purification of contaminated ion beams. In addition, the MR-ToF MS can be operated as a mass spectrometer, either to analyze the ISOLDE ion beam or for precision mass measurements of nuclides that are shorter-lived or that have lower yields than those accessible for Penning-trap mass spectrometry. The MR-ToF MS and corresponding components, its integration into ISOLTRAP, and its various operation modes are reviewed. Furthermore, a precision measurement of the 137Eu mass is presented, determined with the help of the MR-ToF device as a mass separator.oai:inspirehep.net:16159262013 |
spellingShingle | Detectors and Experimental Techniques Wolf, R N Wienholtz, F Atanasov, D Beck, D Blaum, K Borgmann, Ch Herfurth, F Kowalska, M Kreim, S Litvinov, Yu A Lunney, D Manea, V Neidherr, D Rosenbusch, M Schweikhard, L Stanja, J Zuber, K ISOLTRAP's multi-reflection time-of-flight mass separator/spectrometer |
title | ISOLTRAP's multi-reflection time-of-flight mass separator/spectrometer |
title_full | ISOLTRAP's multi-reflection time-of-flight mass separator/spectrometer |
title_fullStr | ISOLTRAP's multi-reflection time-of-flight mass separator/spectrometer |
title_full_unstemmed | ISOLTRAP's multi-reflection time-of-flight mass separator/spectrometer |
title_short | ISOLTRAP's multi-reflection time-of-flight mass separator/spectrometer |
title_sort | isoltrap's multi-reflection time-of-flight mass separator/spectrometer |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.ijms.2013.03.020 http://cds.cern.ch/record/2279141 |
work_keys_str_mv | AT wolfrn isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT wienholtzf isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT atanasovd isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT beckd isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT blaumk isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT borgmannch isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT herfurthf isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT kowalskam isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT kreims isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT litvinovyua isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT lunneyd isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT maneav isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT neidherrd isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT rosenbuschm isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT schweikhardl isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT stanjaj isoltrapsmultireflectiontimeofflightmassseparatorspectrometer AT zuberk isoltrapsmultireflectiontimeofflightmassseparatorspectrometer |