Design of the Palmer Pickup for Stochastic Pre-Cooling of Hot Rare Isotopes at the CR

We report on the design of a Faltin type pickup for the stochastic pre-cooling of rare isotope beams at 740 MeV/u, using a bandwidth of 1-2 GHz, for the Collector Ring (CR) in the FAIR project at GSI. The design difficulties inherent in Faltin rails at these frequencies are described. Measurements o...

Descripción completa

Detalles Bibliográficos
Autores principales: Barker, D J, Dimopoulou, C, Peschke, C, Thorndahl, L
Lenguaje:eng
Publicado: 2015
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-COOL2015-FRWAUD03
http://cds.cern.ch/record/2279142
Descripción
Sumario:We report on the design of a Faltin type pickup for the stochastic pre-cooling of rare isotope beams at 740 MeV/u, using a bandwidth of 1-2 GHz, for the Collector Ring (CR) in the FAIR project at GSI. The design difficulties inherent in Faltin rails at these frequencies are described. Measurements of prototypes and HFSS simulations are compared, to check the simulations, and show good agreement. The pickup impedance and signal output phase with respect to ions traveling at 0.83c are simulated and presented for the final design both with and without the use of damping material, showing the need to damp unwanted modes present in the beam chamber.