Cargando…

rf measurements and tuning of the 750 MHz radio frequency quadrupole

In the framework of the program on medical applications a compact 750 MHz RFQ has been designed and built to be used as an injector for a hadron therapy linac. This RFQ was designed to accelerate protons to an energy of 5 MeV within only 2 m length. It is divided into four segments and equipped with...

Descripción completa

Detalles Bibliográficos
Autores principales: Koubek, Benjamin, Grudiev, Alexej, Timmins, Marc
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.1103/PhysRevAccelBeams.20.080102
http://cds.cern.ch/record/2280550
_version_ 1780955600677502976
author Koubek, Benjamin
Grudiev, Alexej
Timmins, Marc
author_facet Koubek, Benjamin
Grudiev, Alexej
Timmins, Marc
author_sort Koubek, Benjamin
collection CERN
description In the framework of the program on medical applications a compact 750 MHz RFQ has been designed and built to be used as an injector for a hadron therapy linac. This RFQ was designed to accelerate protons to an energy of 5 MeV within only 2 m length. It is divided into four segments and equipped with 32 tuners in total. The length of the RFQ corresponds to 5λ which is considered to be close to the limit for field adjustment using only piston tuners. Moreover the high frequency, which is about double the frequency of existing RFQs, results in a sensitive structure and requires careful tuning. In this paper we present the tuning algorithm, the tuning procedure and rf measurements of the RFQ.
id oai-inspirehep.net-1616014
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling oai-inspirehep.net-16160142022-08-10T12:33:46Zdoi:10.1103/PhysRevAccelBeams.20.080102http://cds.cern.ch/record/2280550engKoubek, BenjaminGrudiev, AlexejTimmins, Marcrf measurements and tuning of the 750 MHz radio frequency quadrupoleAccelerators and Storage RingsIn the framework of the program on medical applications a compact 750 MHz RFQ has been designed and built to be used as an injector for a hadron therapy linac. This RFQ was designed to accelerate protons to an energy of 5 MeV within only 2 m length. It is divided into four segments and equipped with 32 tuners in total. The length of the RFQ corresponds to 5λ which is considered to be close to the limit for field adjustment using only piston tuners. Moreover the high frequency, which is about double the frequency of existing RFQs, results in a sensitive structure and requires careful tuning. In this paper we present the tuning algorithm, the tuning procedure and rf measurements of the RFQ.oai:inspirehep.net:16160142017
spellingShingle Accelerators and Storage Rings
Koubek, Benjamin
Grudiev, Alexej
Timmins, Marc
rf measurements and tuning of the 750 MHz radio frequency quadrupole
title rf measurements and tuning of the 750 MHz radio frequency quadrupole
title_full rf measurements and tuning of the 750 MHz radio frequency quadrupole
title_fullStr rf measurements and tuning of the 750 MHz radio frequency quadrupole
title_full_unstemmed rf measurements and tuning of the 750 MHz radio frequency quadrupole
title_short rf measurements and tuning of the 750 MHz radio frequency quadrupole
title_sort rf measurements and tuning of the 750 mhz radio frequency quadrupole
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1103/PhysRevAccelBeams.20.080102
http://cds.cern.ch/record/2280550
work_keys_str_mv AT koubekbenjamin rfmeasurementsandtuningofthe750mhzradiofrequencyquadrupole
AT grudievalexej rfmeasurementsandtuningofthe750mhzradiofrequencyquadrupole
AT timminsmarc rfmeasurementsandtuningofthe750mhzradiofrequencyquadrupole