Cargando…

Optical Test Stand and SiPM characterisation studies

This thesis deals with developing and commissioning a test stand for optical SiPM characterisations. SiPMs are semiconductor-based photon de- tectors, said to become the classical photomultiplier tube’s (PMT) successor in certain disciplines, where an SiPM’s characteristics seem superior than these...

Descripción completa

Detalles Bibliográficos
Autor principal: Glauss, Benjamin
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:http://cds.cern.ch/record/2286295
_version_ 1780956056647630848
author Glauss, Benjamin
author_facet Glauss, Benjamin
author_sort Glauss, Benjamin
collection CERN
description This thesis deals with developing and commissioning a test stand for optical SiPM characterisations. SiPMs are semiconductor-based photon de- tectors, said to become the classical photomultiplier tube’s (PMT) successor in certain disciplines, where an SiPM’s characteristics seem superior than these of a PMT. The test stand development is based on a given concept, that was devised in the previous bachelor theses [13] and [14]. The two main aspects in this thesis is on the one hand to complete the optics part and on the other hand to incorporate first example SiPM measurements. At the end, there is a solid basis given for complete SiPM characterisation studies, combining separate measurements in a single table-top setup, operating automatically with as little user interaction as possible, run by shell scripts.
id oai-inspirehep.net-1623974
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling oai-inspirehep.net-16239742019-09-30T06:29:59Zhttp://cds.cern.ch/record/2286295engGlauss, BenjaminOptical Test Stand and SiPM characterisation studiesDetectors and Experimental TechniquesThis thesis deals with developing and commissioning a test stand for optical SiPM characterisations. SiPMs are semiconductor-based photon de- tectors, said to become the classical photomultiplier tube’s (PMT) successor in certain disciplines, where an SiPM’s characteristics seem superior than these of a PMT. The test stand development is based on a given concept, that was devised in the previous bachelor theses [13] and [14]. The two main aspects in this thesis is on the one hand to complete the optics part and on the other hand to incorporate first example SiPM measurements. At the end, there is a solid basis given for complete SiPM characterisation studies, combining separate measurements in a single table-top setup, operating automatically with as little user interaction as possible, run by shell scripts.CERN-THESIS-2012-458oai:inspirehep.net:16239742017-09-29T04:24:24Z
spellingShingle Detectors and Experimental Techniques
Glauss, Benjamin
Optical Test Stand and SiPM characterisation studies
title Optical Test Stand and SiPM characterisation studies
title_full Optical Test Stand and SiPM characterisation studies
title_fullStr Optical Test Stand and SiPM characterisation studies
title_full_unstemmed Optical Test Stand and SiPM characterisation studies
title_short Optical Test Stand and SiPM characterisation studies
title_sort optical test stand and sipm characterisation studies
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/2286295
work_keys_str_mv AT glaussbenjamin opticalteststandandsipmcharacterisationstudies