Cargando…
Improved Protection of the Warm Magnets of the LHC Betatron Cleaning Insertion
After the High Luminosity (HL) upgrade in 2024-2026, the LHC is anticipated to increase its integrated luminosity by a factor of 10 beyond its original design value of 300 fb-1. In preparation for this, several improvements to the equipment will already be implemented during the next Long Shutdown (...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2017-MOPAB004 http://cds.cern.ch/record/2289709 |
Sumario: | After the High Luminosity (HL) upgrade in 2024-2026, the LHC is anticipated to increase its integrated luminosity by a factor of 10 beyond its original design value of 300 fb-1. In preparation for this, several improvements to the equipment will already be implemented during the next Long Shutdown (LS2) starting in 2019. In the betatron cleaning insertion, the debris leaking out of several collimators will deposit energy in the downstream warm magnets, causing long-term radiation damage. A new layout has been proposed in which the most exposed magnet of each assembly is removed, reducing the assembly from 6 to 5 magnet units and gaining 2 spare magnets. New absorbers are therefore required to enhance the shielding of the remaining magnet string. In this paper, we present an evaluation of the dose to the warm magnets for post-LS2 operation, and we quantify the achievable reduction of the long-term radiation damage for different absorber configurations. A solution for an improved magnet protection that fulfills the HL-LHC requirements is proposed. |
---|