Cargando…

Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations

The beam intensities at the Extra Low ENergy Antiproton ring ELENA are too low for standard beam current transformers and, thus, are measured with longitudinal Schottky diagnostics. This method is already successfully used at the Antiproton Decelerator since the commissioning of this machine. The fa...

Descripción completa

Detalles Bibliográficos
Autores principales: Carli, Christian, Angoletta, Maria Elena, Caspers, Fritz, Jones, Owain Rhodri, Pedersen, Flemming, Sanchez-Quesada, Jorge, Søby, Lars
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-IPAC2017-MOPAB112
http://cds.cern.ch/record/2289124
_version_ 1780956328435384320
author Carli, Christian
Angoletta, Maria Elena
Caspers, Fritz
Jones, Owain Rhodri
Pedersen, Flemming
Sanchez-Quesada, Jorge
Søby, Lars
author_facet Carli, Christian
Angoletta, Maria Elena
Caspers, Fritz
Jones, Owain Rhodri
Pedersen, Flemming
Sanchez-Quesada, Jorge
Søby, Lars
author_sort Carli, Christian
collection CERN
description The beam intensities at the Extra Low ENergy Antiproton ring ELENA are too low for standard beam current transformers and, thus, are measured with longitudinal Schottky diagnostics. This method is already successfully used at the Antiproton Decelerator since the commissioning of this machine. The fact that Schottky noise is a statistical phenomenon implies statistical errors of these measurements. Simple analytical formulas describing the statistical error to be expected as a function of the frequency spread of the band considered, the time resolution chosen and the background noise have been derived. On the one hand, low revolution harmonics and, in turn, frequency spread of the band analysed lead to large measurement errors as this situation corresponds to low momentum resolution of the resulting distribution describing the beam. At very large revolution harmonics and, thus, frequency spreads of the band analysed, the measurement error increases again due to additional contributions from the background noise.
id oai-inspirehep.net-1626516
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling oai-inspirehep.net-16265162019-09-30T06:29:59Zdoi:10.18429/JACoW-IPAC2017-MOPAB112http://cds.cern.ch/record/2289124engCarli, ChristianAngoletta, Maria ElenaCaspers, FritzJones, Owain RhodriPedersen, FlemmingSanchez-Quesada, JorgeSøby, LarsSchottky Based Intensity Measurements and Errors Due to Statistical FluctuationsAccelerators and Storage RingsThe beam intensities at the Extra Low ENergy Antiproton ring ELENA are too low for standard beam current transformers and, thus, are measured with longitudinal Schottky diagnostics. This method is already successfully used at the Antiproton Decelerator since the commissioning of this machine. The fact that Schottky noise is a statistical phenomenon implies statistical errors of these measurements. Simple analytical formulas describing the statistical error to be expected as a function of the frequency spread of the band considered, the time resolution chosen and the background noise have been derived. On the one hand, low revolution harmonics and, in turn, frequency spread of the band analysed lead to large measurement errors as this situation corresponds to low momentum resolution of the resulting distribution describing the beam. At very large revolution harmonics and, thus, frequency spreads of the band analysed, the measurement error increases again due to additional contributions from the background noise.CERN-ACC-2017-281oai:inspirehep.net:16265162017
spellingShingle Accelerators and Storage Rings
Carli, Christian
Angoletta, Maria Elena
Caspers, Fritz
Jones, Owain Rhodri
Pedersen, Flemming
Sanchez-Quesada, Jorge
Søby, Lars
Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations
title Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations
title_full Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations
title_fullStr Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations
title_full_unstemmed Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations
title_short Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations
title_sort schottky based intensity measurements and errors due to statistical fluctuations
topic Accelerators and Storage Rings
url https://dx.doi.org/10.18429/JACoW-IPAC2017-MOPAB112
http://cds.cern.ch/record/2289124
work_keys_str_mv AT carlichristian schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations
AT angolettamariaelena schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations
AT caspersfritz schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations
AT jonesowainrhodri schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations
AT pedersenflemming schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations
AT sanchezquesadajorge schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations
AT søbylars schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations