Cargando…
Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations
The beam intensities at the Extra Low ENergy Antiproton ring ELENA are too low for standard beam current transformers and, thus, are measured with longitudinal Schottky diagnostics. This method is already successfully used at the Antiproton Decelerator since the commissioning of this machine. The fa...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2017-MOPAB112 http://cds.cern.ch/record/2289124 |
_version_ | 1780956328435384320 |
---|---|
author | Carli, Christian Angoletta, Maria Elena Caspers, Fritz Jones, Owain Rhodri Pedersen, Flemming Sanchez-Quesada, Jorge Søby, Lars |
author_facet | Carli, Christian Angoletta, Maria Elena Caspers, Fritz Jones, Owain Rhodri Pedersen, Flemming Sanchez-Quesada, Jorge Søby, Lars |
author_sort | Carli, Christian |
collection | CERN |
description | The beam intensities at the Extra Low ENergy Antiproton ring ELENA are too low for standard beam current transformers and, thus, are measured with longitudinal Schottky diagnostics. This method is already successfully used at the Antiproton Decelerator since the commissioning of this machine. The fact that Schottky noise is a statistical phenomenon implies statistical errors of these measurements. Simple analytical formulas describing the statistical error to be expected as a function of the frequency spread of the band considered, the time resolution chosen and the background noise have been derived. On the one hand, low revolution harmonics and, in turn, frequency spread of the band analysed lead to large measurement errors as this situation corresponds to low momentum resolution of the resulting distribution describing the beam. At very large revolution harmonics and, thus, frequency spreads of the band analysed, the measurement error increases again due to additional contributions from the background noise. |
id | oai-inspirehep.net-1626516 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2017 |
record_format | invenio |
spelling | oai-inspirehep.net-16265162019-09-30T06:29:59Zdoi:10.18429/JACoW-IPAC2017-MOPAB112http://cds.cern.ch/record/2289124engCarli, ChristianAngoletta, Maria ElenaCaspers, FritzJones, Owain RhodriPedersen, FlemmingSanchez-Quesada, JorgeSøby, LarsSchottky Based Intensity Measurements and Errors Due to Statistical FluctuationsAccelerators and Storage RingsThe beam intensities at the Extra Low ENergy Antiproton ring ELENA are too low for standard beam current transformers and, thus, are measured with longitudinal Schottky diagnostics. This method is already successfully used at the Antiproton Decelerator since the commissioning of this machine. The fact that Schottky noise is a statistical phenomenon implies statistical errors of these measurements. Simple analytical formulas describing the statistical error to be expected as a function of the frequency spread of the band considered, the time resolution chosen and the background noise have been derived. On the one hand, low revolution harmonics and, in turn, frequency spread of the band analysed lead to large measurement errors as this situation corresponds to low momentum resolution of the resulting distribution describing the beam. At very large revolution harmonics and, thus, frequency spreads of the band analysed, the measurement error increases again due to additional contributions from the background noise.CERN-ACC-2017-281oai:inspirehep.net:16265162017 |
spellingShingle | Accelerators and Storage Rings Carli, Christian Angoletta, Maria Elena Caspers, Fritz Jones, Owain Rhodri Pedersen, Flemming Sanchez-Quesada, Jorge Søby, Lars Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations |
title | Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations |
title_full | Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations |
title_fullStr | Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations |
title_full_unstemmed | Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations |
title_short | Schottky Based Intensity Measurements and Errors Due to Statistical Fluctuations |
title_sort | schottky based intensity measurements and errors due to statistical fluctuations |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.18429/JACoW-IPAC2017-MOPAB112 http://cds.cern.ch/record/2289124 |
work_keys_str_mv | AT carlichristian schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations AT angolettamariaelena schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations AT caspersfritz schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations AT jonesowainrhodri schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations AT pedersenflemming schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations AT sanchezquesadajorge schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations AT søbylars schottkybasedintensitymeasurementsanderrorsduetostatisticalfluctuations |