Cargando…
Pre-Alignment Techniques Developments and Measurement Results of the Electromagnetic Center of Warm High-Gradient Accelerating Structures
In the framework of the PACMAN project we have developed a test set-up to measure the electromagnetic centre of high gradient accelerating structures for alignment purposes. We have demonstrated with previous simulation studies that a resolution of 1 m is possible. The improvements applied on the te...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2017-TUPIK076 http://cds.cern.ch/record/2289155 |
Sumario: | In the framework of the PACMAN project we have developed a test set-up to measure the electromagnetic centre of high gradient accelerating structures for alignment purposes. We have demonstrated with previous simulation studies that a resolution of 1 m is possible. The improvements applied on the technique and on the set-up, calibrations and the equipment instrumentation allows the measurement of the electromagnetic centre, with a final precision of 1.09 m in the horizontal plane and 0.58 m in the vertical plane. The experimental measurements and the simulation studies as a support to justify the numbers obtained are presented and discussed. |
---|