In the framework of the PACMAN project we have developed a test set-up to measure the electromagnetic centre of high gradient accelerating structures for alignment purposes. We have demonstrated with previous simulation studies that a resolution of 1 m is possible. The improvements applied on the te...

Descripción completa

Detalles Bibliográficos
Autores principales: Galindo Munoz, Natalia, Boria, Vicente, Catalán Lasheras, Nuria, Faus-Golfe, Angeles
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-IPAC2017-TUPIK076
http://cds.cern.ch/record/2289155
Descripción
Sumario:In the framework of the PACMAN project we have developed a test set-up to measure the electromagnetic centre of high gradient accelerating structures for alignment purposes. We have demonstrated with previous simulation studies that a resolution of 1 m is possible. The improvements applied on the technique and on the set-up, calibrations and the equipment instrumentation allows the measurement of the electromagnetic centre, with a final precision of 1.09 m in the horizontal plane and 0.58 m in the vertical plane. The experimental measurements and the simulation studies as a support to justify the numbers obtained are presented and discussed.