Cargando…
Study of a Triple GEM detector for the upgrade in the forward region of the CMS Muon System at the LHC
In the coming years, the LHC will enter its phase of high luminosity. As a result the CMS detector complex will be subjected to a high flux rate of particles in the forward region of the muon spectrometer. The purpose of this work is to study Triple GEM detectors for the upgrade in the 1.6 < |⌘|...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/2290839 |
Sumario: | In the coming years, the LHC will enter its phase of high luminosity. As a
result the CMS detector complex will be subjected to a high flux rate of particles
in the forward region of the muon spectrometer. The purpose of this work is to
study Triple GEM detectors for the upgrade in the 1.6 < |⌘| < 2.4 part of the muon
spectrometer in CMS in order to increase the redundancy in this region. The major
advantage of this new technology is its high detection efficiency under high rates of
radiation fluxes.
This work is aimed at modeling the response of a Triple GEM detector, ranging
from the simulation of a primary ionization, the electron avalanche process to the formation
of the signal on the readout electronics. Certain results of this computations
will be confronted with real measurements taken with a Triple GEM prototype. |
---|