Cargando…

DHCAL with minimal absorber: measurements with positrons

In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction le...

Descripción completa

Detalles Bibliográficos
Autores principales: Freund, B, Bilki, B, Corriveau, F, Neubüser, C, Onel, Y, Repond, J
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1742-6596/928/1/012037
http://cds.cern.ch/record/2311672
_version_ 1780957945781026816
author Freund, B
Bilki, B
Corriveau, F
Neubüser, C
Onel, Y
Repond, J
author_facet Freund, B
Bilki, B
Corriveau, F
Neubüser, C
Onel, Y
Repond, J
author_sort Freund, B
collection CERN
description In special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.
id oai-inspirehep.net-1639989
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling oai-inspirehep.net-16399892021-02-09T10:07:07Zdoi:10.1088/1742-6596/928/1/012037http://cds.cern.ch/record/2311672engFreund, BBilki, BCorriveau, FNeubüser, COnel, YRepond, JDHCAL with minimal absorber: measurements with positronsDetectors and Experimental TechniquesIn special tests, the active layers of the CALICE Digital Hadron Calorimeter prototype, the DHCAL, were exposed to low energy particle beams, without being interleaved by absorber plates. The thickness of each layer corresponded approximately to 0.29 radiation lengths or 0.034 nuclear interaction lengths, defined mostly by the copper and steel skins of the detector cassettes. This paper reports on measurements performed with this device in the Fermilab test beam with positrons in the energy range of 1 to 10 GeV. The measurements are compared to simulations based on GEANT4 and a standalone program to emulate the detailed response of the active elements.oai:inspirehep.net:16399892017
spellingShingle Detectors and Experimental Techniques
Freund, B
Bilki, B
Corriveau, F
Neubüser, C
Onel, Y
Repond, J
DHCAL with minimal absorber: measurements with positrons
title DHCAL with minimal absorber: measurements with positrons
title_full DHCAL with minimal absorber: measurements with positrons
title_fullStr DHCAL with minimal absorber: measurements with positrons
title_full_unstemmed DHCAL with minimal absorber: measurements with positrons
title_short DHCAL with minimal absorber: measurements with positrons
title_sort dhcal with minimal absorber: measurements with positrons
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1742-6596/928/1/012037
http://cds.cern.ch/record/2311672
work_keys_str_mv AT freundb dhcalwithminimalabsorbermeasurementswithpositrons
AT bilkib dhcalwithminimalabsorbermeasurementswithpositrons
AT corriveauf dhcalwithminimalabsorbermeasurementswithpositrons
AT neubuserc dhcalwithminimalabsorbermeasurementswithpositrons
AT onely dhcalwithminimalabsorbermeasurementswithpositrons
AT repondj dhcalwithminimalabsorbermeasurementswithpositrons