Cargando…

Measurement of the $^{238}\mathrm{U}(n,\gamma)$ cross section up to 80 keV with the Total Absorption Calorimeter at the CERN n_TOF facility

The radiative capture cross section of a highly pure (99.999%), 6.125(2) grams and $9.56(5) \times 10^{−4}$ atoms/barn areal density $^{238}$U sample has been measured with the Total Absorption Calorimeter (TAC) in the 185 m flight path at the CERN neutron time-of-flight facility n_TOF. This measure...

Descripción completa

Detalles Bibliográficos
Autores principales: Wright, T, Guerrero, C, Billowes, J, Cano-Ott, D, Mendoza, E, Altstadt, S, Andrzejewski, J, Audouin, L, Bécares, V, Barbagallo, M, Bečvář, F, Belloni, F, Berthoumieux, E, Bosnar, D, Brugger, M, Calviño, F, Calviani, M, Carrapiço, C, Cerutti, F, Chiaveri, E, Chin, M, Colonna, N, Cortés, G, Cortés-Giraldo, M A, Diakaki, M, Dietz, M, Domingo-Pardo, C, Durán, I, Dzysiuk, N, Eleftheriadis, C, Ferrari, A, Fraval, K, Furman, V, Gómez-Hornillos, M B, Ganesan, S, García, A R, Giubrone, G, Gonçalves, I F, González-Romero, E, Goverdovski, A, Griesmayer, E, Gunsing, F, Gurusamy, P, Heftrich, T, Hernández-Prieto, A, Jenkins, D G, Jericha, E, Käppeler, F, Kadi, Y, Karadimos, D, Katabuchi, T, Ketlerov, V, Khryachkov, V, Koehler, P, Kokkoris, M, Kroll, J, Krtička, M, Lampoudis, C, Langer, C, Leal-Cidoncha, E, Lederer, C, Leeb, H, Leong, L S, Lerendegui-Marco, J, Losito, R, Manousos, A, Marganiec, J, Martínez, T, Massimi, C, Mastinu, P, Mengoni, A, Milazzo, P M, Mingrone, F, Mirea, M, Paradela, C, Pavlik, A, Perkowski, J, Praena, J, Quesada, J M, Rauscher, T, Reifarth, R, Riego-Perez, A, Robles, M, Roman, F, Rubbia, C, Ryan, J A, Sabaté-Gilarte, M, Sarmento, R, Saxena, A, Schillebeeckx, P, Schmidt, S, Schumann, D, Sedyshev, P, Tagliente, G, Tain, J L, Tarifeño-Saldivia, A, Tarrío, D, Tassan-Got, L, Tsinganis, A, Valenta, S, Vannini, G, Variale, V, Vaz, P, Ventura, A, Vermeulen, M J, Versaci, R, Vlachoudis, V, Vlastou, R, Wallner, A, Ware, T, Weigand, M, Weiss, C, Žugec, P
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.1103/PhysRevC.96.064601
http://cds.cern.ch/record/2306352
Descripción
Sumario:The radiative capture cross section of a highly pure (99.999%), 6.125(2) grams and $9.56(5) \times 10^{−4}$ atoms/barn areal density $^{238}$U sample has been measured with the Total Absorption Calorimeter (TAC) in the 185 m flight path at the CERN neutron time-of-flight facility n_TOF. This measurement is in response to the NEA High Priority Request list, which demands an accuracy in this cross section of less than 3% below 25 keV. These data have undergone careful background subtraction, with special care being given to the background originating from neutrons scattered by the $^{238}$U sample. Pileup and dead-time effects have been corrected for. The measured cross section covers an energy range between 0.2 eV and 80 keV, with an accuracy that varies with neutron energy, being better than 4% below 25 keV and reaching at most 6% at higher energies.