Cargando…
Mirror system of the RICH detector of the NA62 experiment
A large RICH detector is used in NA62 to suppress the muon contamination in the charged pion selection by a factor 100 in the momentum range between 15 and 35 GeV/c. The detector consists of a 17 m long tank (vessel), filled with neon gas at atmospheric pressure. Cherenkov light is reflected by a mo...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/12/12/P12017 http://cds.cern.ch/record/2306354 |
_version_ | 1780957648035774464 |
---|---|
author | Aisa, D Anzivino, G Barbanera, M Bizzarri, M Bizzeti, A Bucci, F Campeggi, C Carassiti, V Cassese, A Cenci, P Ciaranfi, R David, C Duk, V Iacopini, E Imbergamo, E Latino, G Lenti, M Lollini, R Maletta, F Pepe, M Piccini, M Piluso, A Schneider, T Scolieri, G Van Stenis, M Volpe, R |
author_facet | Aisa, D Anzivino, G Barbanera, M Bizzarri, M Bizzeti, A Bucci, F Campeggi, C Carassiti, V Cassese, A Cenci, P Ciaranfi, R David, C Duk, V Iacopini, E Imbergamo, E Latino, G Lenti, M Lollini, R Maletta, F Pepe, M Piccini, M Piluso, A Schneider, T Scolieri, G Van Stenis, M Volpe, R |
author_sort | Aisa, D |
collection | CERN |
description | A large RICH detector is used in NA62 to suppress the muon contamination in the charged pion selection by a factor 100 in the momentum range between 15 and 35 GeV/c. The detector consists of a 17 m long tank (vessel), filled with neon gas at atmospheric pressure. Cherenkov light is reflected by a mosaic of 20 spherical mirrors with 17 m focal length, placed at the downstream end, and collected by 1952 photomultipliers (PMTs) placed at the upstream end. In this paper the characterization of the mirrors before installation and the mirror support system are described. The mirror installation procedure and the laser alignment are also illustrated. |
id | oai-inspirehep.net-1643721 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2017 |
record_format | invenio |
spelling | oai-inspirehep.net-16437212019-10-15T15:17:05Zdoi:10.1088/1748-0221/12/12/P12017http://cds.cern.ch/record/2306354engAisa, DAnzivino, GBarbanera, MBizzarri, MBizzeti, ABucci, FCampeggi, CCarassiti, VCassese, ACenci, PCiaranfi, RDavid, CDuk, VIacopini, EImbergamo, ELatino, GLenti, MLollini, RMaletta, FPepe, MPiccini, MPiluso, ASchneider, TScolieri, GVan Stenis, MVolpe, RMirror system of the RICH detector of the NA62 experimentDetectors and Experimental TechniquesA large RICH detector is used in NA62 to suppress the muon contamination in the charged pion selection by a factor 100 in the momentum range between 15 and 35 GeV/c. The detector consists of a 17 m long tank (vessel), filled with neon gas at atmospheric pressure. Cherenkov light is reflected by a mosaic of 20 spherical mirrors with 17 m focal length, placed at the downstream end, and collected by 1952 photomultipliers (PMTs) placed at the upstream end. In this paper the characterization of the mirrors before installation and the mirror support system are described. The mirror installation procedure and the laser alignment are also illustrated.oai:inspirehep.net:16437212017 |
spellingShingle | Detectors and Experimental Techniques Aisa, D Anzivino, G Barbanera, M Bizzarri, M Bizzeti, A Bucci, F Campeggi, C Carassiti, V Cassese, A Cenci, P Ciaranfi, R David, C Duk, V Iacopini, E Imbergamo, E Latino, G Lenti, M Lollini, R Maletta, F Pepe, M Piccini, M Piluso, A Schneider, T Scolieri, G Van Stenis, M Volpe, R Mirror system of the RICH detector of the NA62 experiment |
title | Mirror system of the RICH detector of the NA62 experiment |
title_full | Mirror system of the RICH detector of the NA62 experiment |
title_fullStr | Mirror system of the RICH detector of the NA62 experiment |
title_full_unstemmed | Mirror system of the RICH detector of the NA62 experiment |
title_short | Mirror system of the RICH detector of the NA62 experiment |
title_sort | mirror system of the rich detector of the na62 experiment |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1748-0221/12/12/P12017 http://cds.cern.ch/record/2306354 |
work_keys_str_mv | AT aisad mirrorsystemoftherichdetectorofthena62experiment AT anzivinog mirrorsystemoftherichdetectorofthena62experiment AT barbaneram mirrorsystemoftherichdetectorofthena62experiment AT bizzarrim mirrorsystemoftherichdetectorofthena62experiment AT bizzetia mirrorsystemoftherichdetectorofthena62experiment AT buccif mirrorsystemoftherichdetectorofthena62experiment AT campeggic mirrorsystemoftherichdetectorofthena62experiment AT carassitiv mirrorsystemoftherichdetectorofthena62experiment AT cassesea mirrorsystemoftherichdetectorofthena62experiment AT cencip mirrorsystemoftherichdetectorofthena62experiment AT ciaranfir mirrorsystemoftherichdetectorofthena62experiment AT davidc mirrorsystemoftherichdetectorofthena62experiment AT dukv mirrorsystemoftherichdetectorofthena62experiment AT iacopinie mirrorsystemoftherichdetectorofthena62experiment AT imbergamoe mirrorsystemoftherichdetectorofthena62experiment AT latinog mirrorsystemoftherichdetectorofthena62experiment AT lentim mirrorsystemoftherichdetectorofthena62experiment AT lollinir mirrorsystemoftherichdetectorofthena62experiment AT malettaf mirrorsystemoftherichdetectorofthena62experiment AT pepem mirrorsystemoftherichdetectorofthena62experiment AT piccinim mirrorsystemoftherichdetectorofthena62experiment AT pilusoa mirrorsystemoftherichdetectorofthena62experiment AT schneidert mirrorsystemoftherichdetectorofthena62experiment AT scolierig mirrorsystemoftherichdetectorofthena62experiment AT vanstenism mirrorsystemoftherichdetectorofthena62experiment AT volper mirrorsystemoftherichdetectorofthena62experiment |