Cargando…

Beam measurements of the SPS longitudinal impedance

Longitudinal instabilities are one of the main limitationsin the CERN SPS to reach the beam parameters requiredfor the High Luminosity LHC project. In preparation tothe SPS upgrade, possible remedies are studied by perform-ing macroparticle simulations using the machine impedancemodel obtained from...

Descripción completa

Detalles Bibliográficos
Autores principales: Lasheen, A, Shaposhnikova, E
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.23727/CERN-Proceedings-2017-002.73
http://cds.cern.ch/record/2301804
_version_ 1780957263549169664
author Lasheen, A
Shaposhnikova, E
author_facet Lasheen, A
Shaposhnikova, E
author_sort Lasheen, A
collection CERN
description Longitudinal instabilities are one of the main limitationsin the CERN SPS to reach the beam parameters requiredfor the High Luminosity LHC project. In preparation tothe SPS upgrade, possible remedies are studied by perform-ing macroparticle simulations using the machine impedancemodel obtained from electromagnetic simulations and mea-surements. To benchmark the impedance model, the resultsof simulations are compared with various beam measure-ments. In this study, the reactive part of the impedance wasprobed by measuring the quadrupole frequency shift withintensity, obtained from bunch length oscillations at mis-matched injection into the SPS. This method was appliedover many last years to follow up the evolution of the SPSimpedance, injecting bunches with the same bunch length.A novel approach, giving significantly more information,consists in varying the injected bunch length. The compari-son of these measurements with macroparticle simulationsallowed to test the existing model and identify some missingSPS impedance and to obtain its possible dependence onfrequency
id oai-inspirehep.net-1649879
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling oai-inspirehep.net-16498792019-09-30T06:29:59Zdoi:10.23727/CERN-Proceedings-2017-002.73http://cds.cern.ch/record/2301804engLasheen, AShaposhnikova, EBeam measurements of the SPS longitudinal impedanceAccelerators and Storage RingsLongitudinal instabilities are one of the main limitationsin the CERN SPS to reach the beam parameters requiredfor the High Luminosity LHC project. In preparation tothe SPS upgrade, possible remedies are studied by perform-ing macroparticle simulations using the machine impedancemodel obtained from electromagnetic simulations and mea-surements. To benchmark the impedance model, the resultsof simulations are compared with various beam measure-ments. In this study, the reactive part of the impedance wasprobed by measuring the quadrupole frequency shift withintensity, obtained from bunch length oscillations at mis-matched injection into the SPS. This method was appliedover many last years to follow up the evolution of the SPSimpedance, injecting bunches with the same bunch length.A novel approach, giving significantly more information,consists in varying the injected bunch length. The compari-son of these measurements with macroparticle simulationsallowed to test the existing model and identify some missingSPS impedance and to obtain its possible dependence onfrequencyoai:inspirehep.net:16498792017
spellingShingle Accelerators and Storage Rings
Lasheen, A
Shaposhnikova, E
Beam measurements of the SPS longitudinal impedance
title Beam measurements of the SPS longitudinal impedance
title_full Beam measurements of the SPS longitudinal impedance
title_fullStr Beam measurements of the SPS longitudinal impedance
title_full_unstemmed Beam measurements of the SPS longitudinal impedance
title_short Beam measurements of the SPS longitudinal impedance
title_sort beam measurements of the sps longitudinal impedance
topic Accelerators and Storage Rings
url https://dx.doi.org/10.23727/CERN-Proceedings-2017-002.73
http://cds.cern.ch/record/2301804
work_keys_str_mv AT lasheena beammeasurementsofthespslongitudinalimpedance
AT shaposhnikovae beammeasurementsofthespslongitudinalimpedance