Cargando…

Beam Energy Measurement by Resonant Depolarization Method at VEPP-4M

Experiments on high precision mass measurement of particles require precise beam energy calibration. The most accurate method of beam energy measurement is the resonant depolarization technique. This article describes the beam energy measurement at the VEPP-4M storage ring using this method together...

Descripción completa

Detalles Bibliográficos
Autores principales: Blinov, V E, Ivakin, V O, Kaminskiy, V V, Kudryavtsev, V N, Nikitin, S A, Nikolaev, I B, Shekhtman, L I
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.23727/CERN-Proceedings-2017-001.109
http://cds.cern.ch/record/2302005
_version_ 1780957269738913792
author Blinov, V E
Ivakin, V O
Kaminskiy, V V
Kudryavtsev, V N
Nikitin, S A
Nikolaev, I B
Shekhtman, L I
author_facet Blinov, V E
Ivakin, V O
Kaminskiy, V V
Kudryavtsev, V N
Nikitin, S A
Nikolaev, I B
Shekhtman, L I
author_sort Blinov, V E
collection CERN
description Experiments on high precision mass measurement of particles require precise beam energy calibration. The most accurate method of beam energy measurement is the resonant depolarization technique. This article describes the beam energy measurement at the VEPP-4M storage ring using this method together with a Touschek polarimeter. The accuracy achieved is about 10−6. More than thousand energy calibrations were used in the KEDR detector for the precise experiments on the measurement of J/ψ, ψ(2S), ψ(3770), D+, D0 meson and τ lepton masses.
id oai-inspirehep.net-1650329
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling oai-inspirehep.net-16503292019-09-30T06:29:59Zdoi:10.23727/CERN-Proceedings-2017-001.109http://cds.cern.ch/record/2302005engBlinov, V EIvakin, V OKaminskiy, V VKudryavtsev, V NNikitin, S ANikolaev, I BShekhtman, L IBeam Energy Measurement by Resonant Depolarization Method at VEPP-4MAccelerators and Storage RingsExperiments on high precision mass measurement of particles require precise beam energy calibration. The most accurate method of beam energy measurement is the resonant depolarization technique. This article describes the beam energy measurement at the VEPP-4M storage ring using this method together with a Touschek polarimeter. The accuracy achieved is about 10−6. More than thousand energy calibrations were used in the KEDR detector for the precise experiments on the measurement of J/ψ, ψ(2S), ψ(3770), D+, D0 meson and τ lepton masses.oai:inspirehep.net:16503292017
spellingShingle Accelerators and Storage Rings
Blinov, V E
Ivakin, V O
Kaminskiy, V V
Kudryavtsev, V N
Nikitin, S A
Nikolaev, I B
Shekhtman, L I
Beam Energy Measurement by Resonant Depolarization Method at VEPP-4M
title Beam Energy Measurement by Resonant Depolarization Method at VEPP-4M
title_full Beam Energy Measurement by Resonant Depolarization Method at VEPP-4M
title_fullStr Beam Energy Measurement by Resonant Depolarization Method at VEPP-4M
title_full_unstemmed Beam Energy Measurement by Resonant Depolarization Method at VEPP-4M
title_short Beam Energy Measurement by Resonant Depolarization Method at VEPP-4M
title_sort beam energy measurement by resonant depolarization method at vepp-4m
topic Accelerators and Storage Rings
url https://dx.doi.org/10.23727/CERN-Proceedings-2017-001.109
http://cds.cern.ch/record/2302005
work_keys_str_mv AT blinovve beamenergymeasurementbyresonantdepolarizationmethodatvepp4m
AT ivakinvo beamenergymeasurementbyresonantdepolarizationmethodatvepp4m
AT kaminskiyvv beamenergymeasurementbyresonantdepolarizationmethodatvepp4m
AT kudryavtsevvn beamenergymeasurementbyresonantdepolarizationmethodatvepp4m
AT nikitinsa beamenergymeasurementbyresonantdepolarizationmethodatvepp4m
AT nikolaevib beamenergymeasurementbyresonantdepolarizationmethodatvepp4m
AT shekhtmanli beamenergymeasurementbyresonantdepolarizationmethodatvepp4m